ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowTender For Procurement Of Anae, Surat - Tender Details
Explore tender information for Tender For Procurement Of Anae in Surat, including eligibility, deadlines, and bid specifics.
Surat Municipal Corporation
Surat, Gujarat, India
NTID 37737888
- Opening Date : Refer Documents
- Closing Date : Mon 21st October, 2024
- ₹ 6295625.00
- NTID 37737888
Tender For Procurement Of Anaestheticsitems - 1, 50, M1, Blue Radio Opaque Line, Low Pressure High Volume Cuff, Clear Tubing, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, One Way Valve For Efficient And Easy Inflation And Deflation Of Cuff, 100.00, Thermosensitive Pvc Cuffed Et Tube No. 3.5, Number, 33/009/0334/00/0/0/0, 10.00, 5, 50, M1, Blue Radio Opaque Line, Low Pressure High Volume Cuff, Clear Tubing, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, One Way Valve For Efficient And Easy Inflation And Deflation Of Cuff, 100.00, Thermosensitive Pvc Cuffed Et Tube No. 5.5, Number, 33/009/0339/00/0/0/0, 20.00, 9, 50, M1, Blue Radio Opaque Line, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, Portex Material, 100.00, Thermosensitive Pvc Uncuffed Et Tube No.3, Number, 33/009/0343/00/0/0/0, 5.00, 13, 50, M1, Blue Radio Opaque Line, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, Portex Material, 100.00, Thermosensitive Pvc Uncuffed Et Tube No.5, Number, 33/009/0348/00/0/0/0, 5.00, 17, 50, M1, Blue Radio Opaque Line, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, Portex Material, 100.00, Flexomettalic Endotracheal Tube No 5/5.5/6/6.5/7/7.5/8/8.5/9/9.5/10, Number, 33/009/0353/00/0/0/0, 10.00, 21, 50, M1, Thermo Sensitive Clear Pvc Tube, Set Including Stylet, Connectors & Suction Catheters With Radio Opaque Line. Should Have Y Adaptor To Allow Selective Lung Ventilation, Differential Lung Ventilation And Cpap. Colour Coded,lablled Extension Tube And Pilot Balloons Differentiate Bronchial And Tracheal Airways.size : 26f ,28f ,32f, 35 F, 37 F, 39 F,41 F, 6300.00, Laryngeal Mask Airway No 1/1.5/2/2.5/3/4/5, Number, 33/009/0357/00/0/0/0, 70.00, 25, 50, M1, Epidural Touhy Needle 18gx 3.5 In. Pencil Spinal Needle 27gx 5.5 In. Epidural Catheter 20g.closed Tip. 10ml Glass Luer Lock Lor Tray (kit). Filter 0.22 Micron., 2000.00, Epidural Set With Epidural Needle, Number, 33/009/0361/00/0/0/0, 10.00, 29, 50, M1, Needle Shpuld Be Have Echogenicity To Visualise Needle Shaft And Needletip In Sonography. Excellent Puncture And Gliding Properties Through Smooth Surface Precise Stimulation Through The Non-insulated Needle Tip. Short Bevel (30?), Disposable, Needle Of Different Length, Fully Insulated From Shaft To Tip To Precisely Locate The Nerve With Low Current. Comfortable Needle Hub & Adequate Length Of Electric Cable With 2mm Pin & Injection Tube With L.l. Connector., 2300.00, Rae Tube With Cuff (south Pole) No 4.5/5/5.5/6/6.5/7/7.5/8/8.5/9, Number, 33/009/0365/00/0/0/0, 35.00, 33, 50, M1, An Innovative And Unique Bifucated Bronchus Blocker With Y - Shaped Distal End That Mirrors The Bifurcation Of Trachea Allowing Intuitive Placement Of The Cuffs In The Right Or Left Bronchus Without The Need For Navigation. The 75cm Long & 7fr Sized Central Lumen Of Ez Blocker Tm Allows Oxygen Administration (cpap) With The Help Of An Oxygen Adaptor By Attaching It To One Of The 2 Proximal Ends To The Isolated Lung During Procedure And The Other Not In Use Should Be Closed Using One Of The 2 Blue Dust Caps. It Also Allows Co2 Flow Check To Ensure Cuff Is Providing A Full Seal. Low - Volume Cuffs Made Of Polyurethane, Providing Optimal Seal. A Multiport Adaptor (4 Port) With Scope Lid Allow Introduction Of Fibre Optic Or Video Bronchoscopes And Suction Catheters. The Securement Cap Connecting The Multiport Adaptor Allows The Catheter To Be Tightenes Once Properly Positioned, Which Minimizes The Need To Manipulate By Securing Placement And Reduces The Potential For The Cuffs To Become Dislodged. Radiopaque Shaft Provides Visibility Under X - Ray And Depth Markers Indicating The Depth Of Insertion., 1200.00, Laryngeal Mask Airway Fastrach No 3/4/5, Number, 33/009/0369/00/0/0/0, 10.00, 37, 50, M1, The Aintree Intubation Catheter Is A Blunt - Tipped, 19 Fr Radio - Opaque Catheter With An Internal Diameter Of 4.7 Mm And An Outer Diameter Of 6.5 Mm. It Has Total Lenth Of 55 Centimeter With Markings From 5 To 35 Cm On The Outside To Help With Placement., 700.00, Long Spinal Needle No 23/24, Number, 33/009/0375/00/0/0/0, 105.00, 1, 50, M1, Blue Radio Opaque Line, Low Pressure High Volume Cuff, Clear Tubing, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, One Way Valve For Efficient And Easy Inflation And Deflation Of Cuff, 100.00, Thermosensitive Pvc Cuffed Et Tube No. 3.5, Number, 33/009/0334/00/0/0/0, 10.00, 5, 50, M1, Blue Radio Opaque Line, Low Pressure High Volume Cuff, Clear Tubing, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, One Way Valve For Efficient And Easy Inflation And Deflation Of Cuff, 100.00, Thermosensitive Pvc Cuffed Et Tube No. 5.5, Number, 33/009/0339/00/0/0/0, 20.00, 9, 50, M1, Blue Radio Opaque Line, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, Portex Material, 100.00, Thermosensitive Pvc Uncuffed Et Tube No.3, Number, 33/009/0343/00/0/0/0, 5.00, 13, 50, M1, Blue Radio Opaque Line, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, Portex Material, 100.00, Thermosensitive Pvc Uncuffed Et Tube No.5, Number, 33/009/0348/00/0/0/0, 5.00, 17, 50, M1, Blue Radio Opaque Line, Painted Pilot Balloon, Smooth Murphy Eye Thermostatic, Minimizes Risk Of Trauma, Portex Material, 100.00, Flexomettalic Endotracheal Tube No 5/5.5/6/6.5/7/7.5/8/8.5/9/9.5/10, Number, 33/009/0353/00/0/0/0, 10.00, 21, 50, M1, Thermo Sensitive Clear Pvc Tube, Set Including Stylet, Connectors & Suction Catheters With Radio Opaque Line. Should Have Y Adaptor To Allow Selective Lung Ventilation, Differential Lung Ventilation And Cpap. Colour Coded,lablled Extension Tube And Pilot Balloons Differentiate Bronchial And Tracheal Airways.size : 26f ,28f ,32f, 35 F, 37 F, 39 F,41 F, 6300.00, Laryngeal Mask Airway No 1/1.5/2/2.5/3/4/5, Number, 33/009/0357/00/0/0/0, 70.00, 25, 50, M1, Epidural Touhy Needle 18gx 3.5 In. Pencil Spinal Needle 27gx 5.5 In. Epidural Catheter 20g.closed Tip. 10ml Glass Luer Lock Lor Tray (kit). Filter 0.22 Micron., 2000.00, Epidural Set With Epidural Needle, Number, 33/009/0361/00/0/0/0, 10.00, 29, 50, M1, Needle Shpuld Be Have Echogenicity To Visualise Needle Shaft And Needletip In Sonography. Excellent Puncture And Gliding Properties Through Smooth Surface Precise Stimulation Through The Non-insulated Needle Tip. Short Bevel (30?), Disposable, Needle Of Different Length, Fully Insulated From Shaft To Tip To Precisely Locate The Nerve With Low Current. Comfortable Needle Hub & Adequate Length Of Electric Cable With 2mm Pin & Injection Tube With L.l. Connector., 2300.00, Rae Tube With Cuff (south Pole) No 4.5/5/5.5/6/6.5/7/7.5/8/8.5/9, Number, 33/009/0365/00/0/0/0, 35.00, 33, 50, M1, An Innovative And Unique Bifucated Bronchus Blocker With Y - Shaped Distal End That Mirrors The Bifurcation Of Trachea Allowing Intuitive Placement Of The Cuffs In The Right Or Left Bronchus Without The Need For Navigation. The 75cm Long & 7fr Sized Central Lumen Of Ez Blocker Tm Allows Oxygen Administration (cpap) With The Help Of An Oxygen Adaptor By Attaching It To One Of The 2 Proximal Ends To The Isolated Lung During Procedure And The Other Not In Use Should Be Closed Using One Of The 2 Blue Dust Caps. It Also Allows Co2 Flow Check To Ensure Cuff Is Providing A Full Seal. Low - Volume Cuffs Made Of Polyurethane, Providing Optimal Seal. A Multiport Adaptor (4 Port) With Scope Lid Allow Introduction Of Fibre Optic Or Video Bronchoscopes And Suction Catheters. The Securement Cap Connecting The Multiport Adaptor Allows The Catheter To Be Tightenes Once Properly Positioned, Which Minimizes The Need To Manipulate By Securing Placement And Reduces The Potential For The Cuffs To Become Dislodged. Radiopaque Shaft Provides Visibility Under X - Ray And Depth Markers Indicating The Depth Of Insertion., 1200.00, Laryngeal Mask Airway Fastrach No 3/4/5, Number, 33/009/0369/00/0/0/0, 10.00, 37, 50, M1, The Aintree Intubation Catheter Is A Blunt - Tipped, 19 Fr Radio - Opaque Catheter With An Internal Diameter Of 4.7 Mm And An Outer Diameter Of 6.5 Mm. It Has Total Lenth Of 55 Centimeter With Markings From 5 To 35 Cm On The Outside To Help With Placement., 700.00, Long Spinal Needle No 23/24, Number, 33/009/0375/00/0/0/0, 105.00
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
Refer Documents -
Document Cost
2832.00 -
Estimated Cost
6295625.00
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054