Facebook
Description

Supply Of Construction Of G Plus 3 Hexagonal Building In The Technology Campus Of The University Of Calcutta At Salt Lake Kolkata 98 Supply, Installation, Testing And Commissioning Of Fire Detection

Tendering Authority: Public Works Department

India, West Bengal, CALCUTTA

NTID

29323111

Last Date For Submission

29 Nov, 2022

Closing Date

29 Nov, 2022

BOQ Items Total Items : 13 | Total Qty : 2221
# Item Quantity Units
1 Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable multisensor detector IP 42 (VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator is to be provided extra as per NFPA without extra cost) the detectors should have built in LED response indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Honeywell / Ravel). 130 Nos
2 Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Cerberus Pro/ Johnson Controls/Edward/Secutron/ Securiton/ Apollo / Morley / Eaton/ GST / Honeywell / Ravel). 25 Nos
3 Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maximum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator part detector is to be provided extra as per NFPA without extra cost ) the detectors should have built in response LED indicator. (Approved Make: Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST / Honeywell/ Ravel). 20 Nos
4 Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST/System Sensor/Agni Suraksha / Honeywell/ Ravel). 20 Nos
5 Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab/Gloster/KEI) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. 2000 MTR
Tender InquiryInquiry