ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Supply Installa, Lucknow - Tender Details
Explore tender information for Corrigendum Supply Installa in Lucknow, including eligibility, deadlines, and bid specifics.
Food Corporation Of India
Lucknow, Uttar Pradesh, India
NTID 39051181
- Opening Date : Thu 6th February, 2025
- Closing Date : Wed 5th February, 2025
- ₹ 1625219.00
- NTID 39051181
Corrigendum : Supply, Installation, Testing And Commissioning Of 58.5 Kva Diesel Generator Set As Per Cpcb Iv Plus Norms With Amf Panel Including Providing Earthing, Foundation, And Providing Roofing With Profile Sheet Including Fully Comprehensive Guarantee For 02 Years At Fsd Hardoi Under Do Sitapur.
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
32505.00 -
Document Cost
Refer Documents -
Estimated Cost
1625219.00
BOQ Items Total Items : 32 | Total Qty : 124.25
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply, Installation, testing and commissioning of 58.5 kVA , 3 phase ,415 V AC Silent type Liquid cooled diesel driven generating set conforming to CPCB 4 / latest norms comprising of radiator, 4 stroke multi cylinder engine of having minimum 72 BHP at 1500RPM coupled to deliver rated kVA at prevailing site conditions equipped with flywheel, residential type silencer, fuel governor, fuel pump, built in fuel tank, electric starting equipment with required nos of suitable AH sealed maintenance free batteries etc., directly coupled to 58.5 kVA 0.8PF, alternator of same make as engine suitable for 3 phase, 4 wire 50Hz AC supply system with the entire system mounted on common base frame etc. on an existing foundation, exhaust piping with thermal insulation, acoustic enclosure, control wiring from Alternator to control panel,AMF panel of same make as engine having remote monitoring system availavle from the OEM as specified and consisting of the followings and as per specification given below etc. as required. | 1.00 | Each |
2 | Diesel Engine: One number Diesel Engine multi-cylinder, four stroke, liquid cooled, electric start, turbo charged type engine suitable for developing the required BHP at 1500 rpm, suitable for above output of alternator at 40 C, 50% RH and at 1000 Metre MSL and conforming to BS 5514, BS 649, IS:10000, ISO 8528 Part I with upto date amendments/ norms, capable of taking 10% over loading for one hour after 12 hours of continuous operation complete with common base frame, Anti vibration mountings, radiator, starting equipment, batteries, residential type silencer and other accessories etc. as required and as specified in the detailed specification enclosed. Governing Class (As per ISO 8528 part-V) ; Noise Level < 75 dBA/ CPCB NORMS ; Fuel Consumption-(in Litres/Hr) ; At 75% Load-maximum 12; Fuel Tank Capacity-minimum 140 L ; Weight of Gen Set with Canopy- minimum 1350 Kgs (or as per Manufacturer standards) ; Electrical Battery Starting Voltage-12 V DC Engine Specifications- Rated Output (Prime Rating as per ISO 8528)-46 kW/72 HP ; No of Cylinders-4; Rated Speed at 1500 RPM Aspiration - Turbo Aspiration after cooled; Lube Oil Sump Capacity Minimum 8.5 L; Coolant Capacity-Minimum 13 L, DEF Capacity - As per the manufacturer Alternator: Insulation-Class H ; Efficiency at (100% Load)-0.8 pf (As per Standards IS 4722, IEC 34-1)-minimum 90% or as per manufacturer ; Max time to build Rated Voltage at Rated RPM-Voltage Recovery TIme-2 sec | ||
3 | Engine mounted instrument panel fitted with and having digital display for the following: Start- stop switch with Key, Water/ liquid temperature indication, lubrication oil presuure indication, Lubrication oil temperature indication, Battery charging Indication, RPM indication, Over Speed indication, Low lubrication oil trip indication, engine Hours indication. | ||
4 | Alternator: One number synchronous alternator rated at 58.5 kVA, 415 volts at 1500 rpm, 3 phase, 50 Hz. AC supply with 0.8 lagging power factor at 40 C, 50% RH and at 1000 Metre MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited (AREP Based) and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class H insulation | ||
5 | Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channeld with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(Price of foundation needs to be quoted seperately at sr. no. 06) |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054