ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowSupply Installation Testing , Delhi - Tender Details
Explore tender information for Supply Installation Testing in Delhi, including eligibility, deadlines, and bid specifics.
INDIA TRADE PROMOTION ORGANISATION
Delhi, Delhi, India
NTID 38780613
- Opening Date : Thu 16th January, 2025
- Closing Date : Wed 15th January, 2025
- ₹ 38276743.00
- NTID 38780613
Supply, Installation, Testing And Commissioning Of Package Type Substation 11kv/ 433v With Suitable Rating Transformers, Switch Gear Complete At Bharat Mandapam,new Delhi
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
765535.00 -
Document Cost
1180.00 -
Estimated Cost
38276743.00
BOQ Items Total Items : 34 | Total Qty : 4299
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station ,2000 KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC A &B on HT Compartment including Civil foundation 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed / Authorized System Integrators of approved OEM are not allowed to supply . Vacuum Interrupter,RMU,LT Switchgear, Meters and CSS Enciosure shall be of same make to ensure life cycle optimization. Note :- LT Side have to provision of connection of Sandwich Bustrunking of 3200A. Package substation will have the following equipment :- | ||
2 | HT SWITCHGEAR 11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of 2 Nos fixed motorized Load Break switch & 1 no fixed motorized VCB module in SF6 insulated stainless steel enclosure and with Bus PT metering module . Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No. Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. SF6 Gas pressure indicator. Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO CT shall be minimum 60/1A ,2.5VA ,core 1 is 5P20 for protection- 3 nos. CT shall be minimum 60/1A ,2.5VA ,core 2 is calss 0.5 fot metering - 3 nos. All the Load Break switch will have Fault Passage indicator 2X12V, 26AH Battery with Dual Charger - 1 Set 11KV/1.732/110V/1.732 Cast resin Bus PT single phase- 03 set Multifunction meter with Modbus RS485 port & class 0.5 accuracy for each VCB module All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set | ||
3 | Transformer 2000 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date) Max Losses @ 50% Load 4790W and Max Losses @ 100% Load 14100 W and Impedance of 6.25% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. - One No. Winding Temperature Indicator with Alarm and trip Contact | ||
4 | LT Panel LVS PANEL 3200 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) . ; LT panel made up of 1.5/2 mm thick CRCA sheet | ||
5 | Outgoing 3200 Amps 433V 4P 50Hz 50KA Drawout Manual Type Air Circuit Breaker (ACB) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control) to be brought to one set of TBs and a space for FRTU to be given. All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturer's recomandation are included in scope of work. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054