ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry Now
Supply And Installation Of One, Kamrup - Tender Details
Explore tender information for Supply And Installation Of One in Kamrup, including eligibility, deadlines, and bid specifics.
Gujarat University
Kamrup, Assam, India
NTID 39259289
Opening Date : Mon 3rd March, 2025
Closing Date : Mon 3rd March, 2025
- ₹ 300000.00
- NTID 39259289
Supply And Installation Of One Electroporator For The Department Of Botany, Gauhati University
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
Refer Documents -
Document Cost
100.00 -
Estimated Cost
300000.00
BOQ Items Total Items : 2 | Total Qty : 1
# | Item | Quantity | Units |
---|---|---|---|
1 | Electroporator | ||
2 | Supply and installation of one Electroporator Specification of item: i.The system should have One-button pulse delivery, attached cuvette chamber, and rapid charge time for fast sample handling ii. The system should have Preset, optimized programs for commonly studied bacteria and fungi allow rapid program selection iii. The system should have Arc quenching (ARQ) system significantly reduces arcing, protecting against loss of valuable samples iv. The system should have a broad range of parameters for manual optimization. Manual programming allows voltage to be selected in a 200 3,000 V range with 10 V precision and allows pulse width to be selected in a 1.0 4.0 ms range with 0.1 ms precision v. The system should have High-voltage 3,000 V capability yields improved efficiency in larger-volume cuvettes vi. The system should have Compact, space-saving design vii. The system should have audible and visible pulse indicators. viii. The system should have time constant and actual volts displayed to monitor reproducibility ix. Outputs waveform should be decaying or truncated decaying exponential-decay with resistor capacitor time constant Voltage and current: 3,000 V peak into > 600 W load; limited at 100 A peak maximum x.Output voltage and pulse duration adjustment should be Voltage adjustable in 200 3,000 V range with 10 V precision; 5 ms default or 1 4 ms with 0.1 ms precision xi. Input voltage should be 100 120 V or 220 240 V | 1.000 | Nos |

Purchase Access To Download Selected Documents
₹ 200
Select this Plan

For a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054