KERALA WATER AUTHORITY
Kayamkulam, Kerala, India
NTID 38902229
- Opening Date : Thu 16th January, 2025
- Closing Date : Wed 15th January, 2025
- ₹ 1831803.00
- NTID 38902229
State Plan 2024-25 - Cwss To Kayamkulam And Arattupuzha-supply, Erection And Commissioning Of C/f Pump Set Having A Discharge Of 73.89 Lps Against A Head Of 40.00m For Wss To Kayamkulam Atclear Water Pump House At Wtp Pathiyoor.
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
45795.00 -
Document Cost
2760.00 -
Estimated Cost
1831803.00
BOQ Items Total Items : 2 | Total Qty : 1
# | Item | Quantity | Units |
---|---|---|---|
1 | APPENDIX A :- SUPPLY, ERECTION AND COMMISSIONING OF C/F PUMP SET | ||
2 | OD5073/2024-2025:Supply and erection of CF pump set with the following specification - (1) Pump - Supply, erection, testing and commissioning of KWA Prequalified reputed make Centrifugal pump set with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc.complete suitable for coupling the pump and motor above the base plate etc.complete including providing suitable concrete foundation including cost of cement sand and metal etc. complete.The duty condition it as follows :-Discharge - 73.89 LPS Total head - 40 mtrs,Suction head - 4.00 mtrs,Length of the suction pipe - 6.00 mtrs Alternatively the inlet & outlet levels,type,size & length of plumping main etc. can be given. Modification may done for monoblock pump sets. (2) Motor - Supply, erection, testing and commissioning of KWA Prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V.The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc.. Flexible coupling shall be used for coupling of pumps and motors. RPM:-1450 3. Starter Supply , erection, testing and commissioning of suitable rating soft starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, overload relay with motor protection relay with main contractor and bypass contractors And shall conform to the prevailing CEA regulations and other standards and code of practice etc. complete.. 4.Panel board (suitable for operating two pump sets but one pump set at a time) Supply , erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos. suitable capacity MCCB as out going (the two MCCBs are interlocking with each other ) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos. of indicator lamps, 1 No. voltmeter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and interconnect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation 5. Cabling work-Supply, laying ,testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. Considering energy conservation 6. Earthing - Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/ copper strip buried in ground and giving double earthing to motor, starter, panel board etc.as per IE standards. 7.Capacitor - Supply ,erection ,testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834 8. Valves - Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice valve should be in suction as well as delivery sides for easy repair works. 9.Suction and delivery pipe connections - Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8 mm for a total length of 10 M. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valve and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI pipes & specials shall be provided. | 1.000 | set |