ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Special Repair F, Shillong - Tender Details
Explore tender information for Corrigendum Special Repair F in Shillong, including eligibility, deadlines, and bid specifics.
Military Engineer Services
Shillong, Meghalaya, India
NTID 37818162
- Opening Date : Fri 8th November, 2024
- Closing Date : Thu 7th November, 2024
- ₹ 3930000.00
- NTID 37818162
Corrigendum : Special Repair For Replacement Of Ber E/m Equipments Under Ge Narangi - Disconnecting Existing Eletrical Connection To Old Dg Set, Sealing The Cables For Precautions And Safety, Lifting After Taking Down Old Dg Set From Foundation Using Mechanical Equipments / Crane Etc And Loading In Transport Vehicle And Shifting The Old Dg Set To Mes Store Yard Complete All As Specified And As Directed By Engineer-in-charge At Site. Note: The Rate Quoted For This Item Includes For All Necessary Labour And T&p Required For The Job To Be Completed To The Entire Satisfaction Of The Engineer-in-charge., Supply, Installation, Testing And Commissioning Of Silent (sound Proof Enclosure) Type Diesel Engine Driven Generating Set, Capable Of Delivering 75 Kva (60 Kwe)- Crdi At 0.8 Power Factor (lagging)), 103.4 Gross Engine Power (hp) Water And Coolant Cooled, (liquiod Cooled Eg Compleat 50:50) 415 Volts (ac Three Phase, 4 Wire System Of Supply) 50 Hz 1500 Rpm, Current 104 Amp Complete With Automatic On Mains Failure (amf) Control Panel, Governing Class (as Per Iso 8528: Part V)-g3, Conformance Standards, Engine -bs5514, Iso 3046, Alternator - Is 13364 (part-ii), Emission As Per Latest Cpcb Iv+ Norms, Noise Levels As Per Cpcb Norms-less Than 75 Db, Fuel Consumption At 100% Load Not More Than 16.20 Litres/hour, At 75% Load - 12 Litres/hour. The Dg Set Shall Consists Of Diesel Engine Coupled To A Matching Alternator, Through Flexible Coupling And Mounted On Common Base Frame And Complete With Control Panel Suitable For Climatic Conditions Prevalent At Guwahati With Suitable Derating Factors As Applicable And Meeting Specification As Elaborated Here-in After:- Make Of Complete Dg Set:- Cummins Or Equivalent Make In Kirloskar/ Greaves Cotton Compliant With Emission Norms As Per Gsr 804(e) Published In The Gazette Of India Dated 03 Nov 2022., (i) Engine (prime Mover): Diesel Engine 1500 Rpm , Direct Injection, Multi Cylinders, Four Stroke, Confirming To Iso 3046/bs 5514, (performance Class Of Gen Set Iso 8528-5-g2) No Of Cylinders 6, In Line, Water And Coolant Cooled, Naturally Turbo Charged, Capable Of Giving Adequate Power To Drive Alternator Capable Of Delivering 75 Kva/60 Kwe At Outdoor Atmospheric Conditions At Guwahati, (taking All Derating Factor Into Consideration), Starting 12 Volt Dc Battery ( 1 X88ah) Start Complete With Fly Wheel All Standard Fittings/fixtures As Per Oem And Including Suitable Digital Panel With Tachometer, Lub Oil Temperature, Pressure Gauge And Frequency Meters And Also Including Self Starter System, Dynamo, Fuel Electric Control Panel With Electronic Governor (ecpg) And Engine Protection System, (shut Down, High Water Temperature, Low Lub Oil, Oil Pressure, Over Speed Etc) Fuel Tank And First Fill Of Lub Oil And Other Consumables Etc And Self Starting System Incuding Batteries Etc Complete., (ii) Alternator: Brushless Ac Alternator, 3 Phase, 415 Volt, 4 Wire, Rated For Output Of 75 Kva (60 Kwe) At 0.8 Power Factor) 1500 Rpm, Ip 23 Protection Class Enclosure, Insulation Class "h", Salient Pole, Revolving Field, Single Bearing Automatic Voltage Regulator Coupled (voltage Regulation Max + 1%) Through Flexible Coupling With And To Match The Above Engine. Alternator Efficiency At 100% Load 0.8 Pf - Minimum 94.5% And At 75% Load 0.8 Pf - Minimum 94.8%. Permissible Voltage Dip At Full Load 0.8 Pf - Maxmimum 20%. Timer Permitted To Build Up Rated Voltage At Rated Rpm - Maximum 5 Sec Provided Engine Reach The Rated Speed. Short Circuit Withstand Time - 3 Times Rated Current For 10 Secs. Overload Withstand Capacity - 10% Over Load For One Hour Once In 12 Hours. Make Of Alternator: - Cummins/ Stamford/siemens/kirloskar Electric/leroy Semor, (iii) Base Plate: Made Out Of Structural Steel As Per Manufacturers Recommended Design/specifications. (iv) Amf Control Panel: Factory Made Cubicle Type Floor Mounted Amf Panel Board, Duly Powder Coated Manufactured With Crca Sheeet Suiable For Automatic On Mains Failure With Mccb Of Suitable Rating With Short Circuit Protection (mccb - 03 Nos Of Suitable Rating As Per Manufacturers Recommendation For Both Incoming And One Outgoing Connection), Contactor (power Contactor - 03 Nos Of Suitable Rating As Per Manufacturers Recommendation For Both Incoming And One Outgoing Connection), Controller With Displays Of Voltage, Current Kw , Frequency And Kwh Indicating Lamps For " Load-on" And "set Running" , Cts Of Suitable Rating, Aluminium Bus Bars Of Suitable Capacity With Incomimg And Outgoing Terminations And Control Fuses Duly Wired And Ferruled Complete On All Respect. (v) Acoustic Enclosure: Weather And Sound Resistant Enclosure With Insulation Conforming To Ul-94-hf1 Class For Flammabilty And Designed To Meet Latest Moef/cpcb Norms, Sheet Metal Fabricated Cope Type Silent Enclosure Manufactured On Cnc Machines As Per Cpcb Norms And Powder Coated The Enclosure Shall Be Designed For Reducing The Sound Level To 75 Db (a) At A Distance Of 1 M At 75 % Load Under Field Condition And Ox, 70db At 3 M From Gen Set When Dg Set Is Working At Full Load Along With Testing Conformance, Labeling Certification Etc As Laid Down In Gsm No 371 (e) Dt 17 May 2002 And Amendments Thereof.fluid Styling - No Projection. Fluid Drains For Lube Oil And Fuel. Fuel Filling Arrangement Inside The Enclosure., (vi) Foundation/plinth/base: Shall Be Provided As Per Manufacturers Recommendations, However Minimum 0.5 M Space Shall Be Available All Around The Set And Height Of Plinth Shall Not Be Less Than 0.3 M(viii) Diesel Storage Tank Of Capacity Adequate For Storage Of Diesel As Per Manufacturer Specification. (viii) Fully Automatic Ac Operated Additional Battery Charger Of Suitable Capacity Incuding Suitable Size Twin Core Copper Wires Fixed With Copper Lugs Shall Be Provided From Charger To Battery For Charging Of Batteries Without Any Extra Cost To The Government.(ix) Misc: Tool Kit, Operation And Maintenance Catalogue, Spare Part List, Overhauling Manuals, Guarantee Card Etc Shall Be Provided As Per Manufacturer Standard Practices. (x) Controller Shall Be Microprocessor Based Fully Configured With Graphical Lcd Display, Monitoring Features For All Electrical Parameters, Lub Oil Parameters, Battery Parameters And Self Diagnostic Features For All Important Parameters Complete All As Specified And Directed By Engineer-in-charge., Excavating In Trenches Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth For Laying Cables In Trenches And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed By The Engineer-in-charge., Supply, Laying, Jointing And Testing Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-sectional Area 95 Sqmm, 3.5 Core, Complete All As Specified And Directed By Engineer-in-charge At Site. (note: Excavation & Earthwork, Sand Cushioning And Cable Protection Shall Be Measured And Paid Seperately Under Relavent Items Of This Schedule), Material And Labour For Providing Clean Dry River Sand For Cushioning As Protection To Underground Cable, Laid To Required Thickness As Specified In Ssr Part I And Consolidated And Compacted After Punning Down To Required Thickness Complete All As Specified And Directed By Engineer-in-charge At Site., Material And Labour For Laying Well Burnt Old Size Sub Class B Bricks, Laid Flat And Perpendicular To The Direction Of The Cable In Trenches, For Cable Protection, Complete All As Specified And As Directed By The Engineer-in-charge At Site., Returning, Filling In Trenches, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm In Soft / Loose Soil Complete All As Specified And As Directed By The Engineer-in-charge At Site., Removing Excavated Material To A Distance Not Exceeding 50 Metre And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point Complete, All As Specified And As Directed By The Engineer-in-charge At Site., Dismantling And Taking Out Old Cables From Trenches And Supply, Laying, Jointing And Testing 3 (three) Runs Of Pvc Insulated And Pvc Round Sheathed Electric Copper Conductor Cable, 1100 Volts Grade, Cross-sectional Area 10 Sqmm, Single Core Alongwith And Including Earth Wire Of Size 6 Sqmm Drawn Through And Including Rigid Pvc Conduit, 40mm Dia, Laid In Trenches, Complete, All As Specified And As Directed By The Engineer-in-charge At Site. Note: (i) 3 Runs Of 10 Sqmm With 1 Run Of 6 Sqmm Cable And 40 Mm Dia Pvc Conduit Together Shall Be Measured As 1 Run. (ii) All Excavation & Earthwork & Thimbles Required For Above Item Is Included In The Rate Quoted For This Item), Disconnecting Cables Connected To Old Existing Monoblock Pumpset, Sealing The Cables For Safety And Precaution, Taking Out Old Existing Monoblock Pumpset From Foundation And Shifting To Mes Store Yard Complete All As Specified And As Directed By The Engineer-in-charge At Site. Note:- The Rate Quoted For This Item Includes For All Necessary Labour And T&p And Vehicle For Transportation Required For The Job To Be Completed To The Entire Satisfaction Of The Engineer-in-charge., Supplying, Erecting, Commissioning And Testing Of Centrifugal Mono Block Pump Set, With Ci Casing, Impeller And Stainless Steel Shaft Mounted On Heavy Duty Bearings, Suitable For 440 V, 3 Phase, 50 Hz With Discharge Capacity 27.5 Lps At 25 Mtr Head, Confirming To Is- 12469 :1988, 10 Hp Capacity, Water Pump Set Comprising Of The Following Specifications, Complete All As Specified And As Directed By The Engineer-in-charge At Site :- (a) Mono Block Type Pump - 1no(b) Hp Tefc Squirell Cage Induction Motor With Class F Insulation, 1500 Rpm With Synchronous Speed, Operating On 415+ 10% Volts, 3 Phase, 50 Hz A.c Supply - 1no.(c) 100 Mm Dia Dial Type Pressure Gauge - 1 No(d) Mounting Frame With Anti Vibration Pads - 1 Set.(e) Pcc Cement Concrete Foundation For The Pump Unit - 1 Job.(f) Pvc Copper Conductor Of Suitable Size Drawn Through And Inluding Pvc Conduit For Connecting Motor To Starter Panel., Taking Out Carefully Submersible Pumps, Any Type And Of Capacity 10 Hp To 41 Hp, Any Make And Model From The Borewell / Ug Sump / Sewage Well By Disconnecting Electric Connection / Cable Connections From Pumps, Sealing Cables, Opening Nuts & Bolts From Delivery Line And Other Connected Parts And Depositing The Dismantled Submersible Pumps With Mes Storeyard, Complete All As Specified And As Directed By The Engineer-in-charge At Site. Note:- The Rate Quoted For This Item Includes For All Necessary Labour And T&p And Vehicle For Transportation Required For The Job To Be Completed To The Entire Satisfaction Of The Engineer-in-charge., Supplying, Erecting, Testing And Commissioning Of Non Clog Centrifugal Mono Block Booster Pumps For 440 V, 3 Phase, 50 Hz Confirming To Is- 12469 :1988 With Ci Casing, Impeller And Stainless Steel Shaft Mounted On Heavy Duty Bearings Suitable For 440 Volts, 3 Phase, 50 Hz 75-27.5 Lps At Head 10-25 Mtr Water Pump Set Each Comprising Of The Following And As Per Specifications, Complete All As Specified And As Directed By The Engineer-in-charge At Site :- (a) Mono Block Type Pump - 1no(b) Hp Tefc Squirell Cage Induction Motor With Class F Insulation, 1500 Rpm With Synchronous Speed, Operating On 415+ 10% Volts, 3 Phase, 50 Hz A.c Supply - 1no.(c) 100 Mm Dia Dial Type Pressure Gauge - 1 No(d) Mounting Frame With Anti Vibration Pads - 1 Set.(e) Pcc Cement Concrete Foundation For The Pump Unit - 1 Job.(f) Pvc Copper Conductor Of Suitable Size Drawn Through And Inluding Pvc Conduit For Connecting Motor To Starter Panel., Supply, Erection, Testing And Commissioning Of Vertical Non Clog Open Well Type Submersible Pump, Electric Driven 415 V, Tp Suitable For 34 M3 Per Hrs At 50 Mtr Head Complete All As Specified And Directed Each Set Comprising Of The Following And As Per Specifications, Complete All As Specified And As Directed By The Engineer-in-charge At Site :-(a) Mono Block Type Pump - 1no(b) Hp Tefc Squirell Cage Induction Motor With Class F Insulation, 1500 Rpm With Synchronous Speed, Operating On 415+ 10% Volts, 3 Phase, 50 Hz A.c Supply - 1no.(c) 100 Mm Dia Dial Type Pressure Gauge - 1 No(d) Mounting Frame With Anti Vibration Pads - 1 Set.(e) Pcc Cement Concrete Foundation For The Pump Unit - 1 Job.(f) Pvc Copper Conductor Of Suitable Size Drawn Through And Inluding Pvc Conduit For Connecting Motor To Starter Panel., Supply, Erection, Testing And Commissioning Of Vertical Non Clog Open Well Type Submersible Pump, Electric Driven 415 V, Tp Suitable For 100 Lpm At 40 Mtr Head Complete Of Cap 11/15 Kw/hp All As Specified And Directed Each Set Comprising Of The Following Complete All As Specified And As Directed By The Engineer-in-charge At Site :-(a) Vertical Non Clog Open Well Submersible Type Pump - 1 No(b) Suitable Rating Submershible Motor With Class F Insulation 1500 Rpm Synchronous Speed, Operating On 415+ 10% Volts, 3 Phase, 50 Hz A.c. Supply - 1 No(c) 100 Mm Dia Dial Type Pressure Gauges - 1 No.(d) Mounting Frame With Fixing Arrangement - 1 Set(e) Pcc Cement Concrete Foundation For The Pump Unit - 1 Job(f) S & F Nesessary Special Ci Fittings And All Other Fixtures To Fix The Pump-motor In Existing Site., Supply, Installation, Commissioning And Testing Of Non-clog Sewage Pump Set Electric Driven, Three Phase Ac, 415 Volt (+ 5% & +10%), 50 Hz, Rating 9.3 Kw/12.5 Hp Alongwith The Accessories With Cutter Version To Pump Sewage From Collection Tank To Line / Nalah At Uniform Flow Rate , Having Ci Casing, Stainless Steel (cf8m) Impeller, High Carbon Steel Shaft (cs 40c8), Sealing: Double Mechanical Seal Arrangement. Discharge 41 To 14 Lps At 10 To 25 Mtr Head Head With 20 Mm Solid Particle Handling Capacity Suitable For Delivery Pipe 100 Mm Bore, Comprising Of The Following, Complete All As Specified And As Directed By The Engineer-in-charge At Site:- Make: Kirloskar Brothers Ltd (model: Shm) Or Equivalent In Grundfos/ Ksb.(a) S & F Nesessary Special Ci Fittings And All Other Fixtures To Fix The Pump-motor In Existing Site(b) S & F One Pressure Guage 1" Dia With Valve Tee And Fittings.(c) S & F Delivery Pipe 100mm Dia Heavy Duty Flexible Hdpe Pipe From Pump Set To Existing Delivery Pipe Flanged Type With Clamps Complete With All Fitting Suitable For Flanged Pipe And Necessary Nut, Bolts, Washers And Rubber Gasket Etc Including Fixing All As Required. (d) S&f Ms Chain Closed Type Of Size 12mm Including Round Ring Insert On Every Mtr Include Chain Lock, Nuts & Bolts Fixed On Non Clog Sewage Submersible Pump Complete All As Specified And Directed.], Taking Out Old Unsv Dosing Pump From Site And Deposited In Mes Storeyard And Supplying, Fixing, Commissioning And Testing Of Chlorine Dosing Pumping System, Of Cap 12 Lph At 2 Kg/cum And Having Reciprocating Chemical Feeder For Injecting Calcium Hypochloride, Using Motor Driven Reciprocating Chemical Pump, Having Output Of 40 Us Gpd And Adjustable High Pressure Of 100 Psi Complete With All Fittings And Accessories And Assembly, Including Tank And Agitator And Making Connection To Existing Electrial Panel Complete All As Specified And As Directed By The Engineer-in-charge At Site. Make : 96ngq51 Decrin Dosing Pumps Or Equivalent Make In Grundfoss / Milton Roy & Conote For Boq Item Nos 10 To 17:- The Rate Quoted By The Tenderer Is Deemed To Include That He Has Visited The Site Before Quoting Rate For Pumps Under Boq Item Nos 10 To 17 Irrespective Of The Fact Whether He Has Visited Or Not For The Entire Ompletion Of The Above Items To The Entire Satisfaction Of The Engineer - In - Charge. No Extra Payment Whatsoever Shall Be Claimed By The Contractor For Any Additional Parts / Spares / Civil & Electrical Works Which May Be Required For Complete Supply, Erection, Testing And Commissioning Of Pumps Of Any Type During Execution Of Work And The Quoted Rates Are Deemed To Be Inclusive Of The Same., S&f In Repairs, Submersible Flat Cable Of Size 6 Sqmm, 3 Core, 1100 Volts Grade, Copper Conductor Cable, Conforming To Is 694/1990, With Latest Amendments, Laid From Starter To Motor, Drawn Through And Including 40 Mm Dia Rigid Pvc Conduit, Complete All As Specified And As Directed By The Engineer-in-charge At Site. Make Of Cable :- Havells / L&t / Finolex / Plaza, S&f In Repairs, Submersible Flat Cable Of Size 10 Sqmm, 3 Core, 1100 Volts Grade, Copper Conductor Cable, Conforming To Is 694/1990, With Latest Amendments, Laid From Starter To Motor, Drawn Through And Including 40 Mm Dia Rigid Pvc Conduit, Complete All As Specified And As Directed By The Engineer-in-charge At Site. Make Of Cable :- Havells / L&t / Finolex / Plaza, Supply And Fix In Repairs, Star Delta Starter, Fully Automatic, Suitable For Submersible Motor, Fixed On Metal Sheet Of Capacity 50 Hp, 415 V Ac, Including Taking Down Old Unserviceable Starter And Complete All As Specified And As Directed By The Engineer-in-charge At Site., Supply And Fix In Repairs, Star Delta Starter, Fully Automatic, Suitable For Submersible Motor, Fixed On Metal Sheet Of Capacity 30 Hp, 415 V Ac, Including Taking Down Old Unserviceable Starter And Complete All As Specified And As Directed By The Engineer-in-charge At Site., Supply And Fix In Repairs, Star Delta Starter, Fully Automatic, Suitable For Submersible Motor, Fixed On Metal Sheet Of Capacity 20 Hp, 415 V Ac, Including Taking Down Old Unserviceable Starter And Complete All As Specified And As Directed By The Engineer-in-charge At Site., S & F In Repairs, 100 Mm Dia Flanged End Basket With Foot Valve (stainer For Suction) Conforming To Is 4038, Stainer Fabricated From 16 Gauge Brass Sheet With 3 Mm Slots, Made From Ms Body With Bottom And Top Removable Flanges, Nuts, Bolts, Washers Etc Complete Including Joints And Jointing Materials As Per Site Requirement, Including Taking Down Old Unserviceable Foot Valve, Complete All As Specified And As Directed By The Engineer-in-charge At Site., Supply And Fix In Repairs, Sluice Valve Class Pn -1.6, Conforming To Is 14846 - 2000, Long Body Type, Isi Marked With Iron Wheel Head And Stainless Steel Spindle And Fly Nut, Flanged Both Ends, Suitable For 100 Mm Bore Pipe, Including Taking Down Old Unserviceable Sluive Valve, Complete All As Specified And As Directed By The Engineer-in-charge At Site. Make : Kirloskar / Leader / Bir, Supply And Fix In Repairs, Cast Iron Non Return Valve (isi Marked) Confirming To Is 5312 (pt-i), Both Side Flanged Including Nuts, Bolts And Washers, Suitable For 100 Mm Bore Pipe, Including Taking Down Old Unserviceable Non Return Valve, Complete All As Specified And As Directed By The Engineer-in-charge At Site., Supplying, Fixing In Repairs, Including Commissioning And Testing, 100 Mm Bore, "cms" Pipe, 6mm Thick, Isi Marked, Conforming To Is : 1239, Heavy Duty, With All Necessary Fittings Such As Tees, Elbows, Flanges, Reducers, Gaskets, Nuts And Bolts Etc, Including Fabrication, Welding Or Screwed Joints As Required, Including Fixing Of Pipe With Necessary Standard Clamps, Structural Steel Supports As Required, Including Painting With Two Coats Of Synthetic Enamel Paint Of Black Colour Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed By The Engineer-in-charge At Site., Supplying, Fixing, Commissioning And Testing Of Fire Authority Approved Diesel Engine Driven Fire Pump At 41 Veh Pump House Location (standby Pump), Suitable For Automatic Operation, Consisting Of Following:-(a) Horizontally Mounted, Multi Stage, Split Casing Centrifugal Fire Pump With Operating Speed Not Exceeding 1800 Rpm As Per Is : 1520 Complete For Delivery Of 1620 Lpm Discharge Against 70 Mtr Head So As To Ensure A Minimum Pressure Of 35 Meter At The Highest And Farthest Outlet At The Specified Flow Complete With Necessary Strainers, 100mm Dia Dial Pressure Gauge Of Calibration 0-15 Kg/sq Cm. The Pump Shall Be Capable Of Giving 150% Of Rated Discharge At Head Not Less Than 65% Of Rated Head. The Pump Shall Be Provided With Mechanical Seals, The Impeller Shall Be Enclosed Type And Accurately Balanced Dynamically. The Pump Casing Shall Be Of Cast Iron, Impeller Shall Be Of Bronze And Shaft Shall Be Of Stainless Steel. Governing Class (as Per Iso 8528: Part V)-g3, Emission As Per Latest Cpcb Iv+ Norms, Noise Levels As Per Cpcb Norms-less Than 75 Db. The Diesel Fire Engine Set Shall Consists Of Diesel Engine Coupled To A Matching Pumpset, Through Flexible Coupling And Mounted On Common Base Frame And Complete With Fly Wheel All Standard Fittings/fixtures As Per Oem And Including Suitable Digital Panel With Tachometer, Lub Oil Temperature, Pressure Gauge And Also Including Self Starter System, Dynamo, Fuel Electric Control Panel With Electronic Governor (ecpg) And Engine Protection System Suitable For Climatic Conditions Prevalent At Guwahati With Suitable Derating Factors As Applicable And Meeting Specification As Elaborated Here-in After:- Make Of Complete Diesel Fire Engine Set:- Cummins / Kirloskar/ Greaves Cotton Or Equivalent Make As Per Zonal Approval Compliant With Emission Norms As Per Gsr 804(e) Published In The Gazette Of India Dated 03 Nov 2022., (b) Water Cooled Diesel Engine Developing Suitable Bhp For The Above Pump Set, 1500 Rpm Including Engine Control Panel With Manual And Automatic Starting Mechanism, Auto/mannual Selector Switch, 3 Attemt Starting Device, Timers, Relays, Push Buttons, Start/stop In Mannual Mode, 2 Nos Lead Acid Batteries Of 12v 180 Ah Capacity Or As Per Oem Design/ Recommendation, Battery Charger Unit With Boost & Tckle Charger , Selector Switch, 3mm Thick Welded Steel Fabricated Disel Tank For Two Hours Capacity Complete With Inloet And Outlet Connection, Fuel Tubing To The Engine Of Ms C Class, Fuel Filter, Fuel Lift Pump, Oil Level Indication Gauge, Residential Exhaust Silencer, Fly Wheel, Air Intake Manifold, Air Cleaner, Radiator, Radiator Fan, Lub Pressure Gauge, Filter, Cooling Water Temperature Gauge And All Other Accessories Required To Complete The System. The Diesel Engine Shall Be Rated For Continious Duty And Shall Have Bhp Rating Necessary To Drive The Pump At 150% Of Its Rated Discharge At 65% Of Rated Head., (c) Diesel Engine Exhaust System Of Upto 12mtr Length Of Class B Ms Pipe Of Suitable Diameter With Bends, Expansion Joints Including Providing Suitable Supproting Arrangements At Suitable Intervals, With Glass Wool Insulation 50mm Thick On All Sides Of Exhaust Pipe And Silencer, With Chicken Mesh Wrapping And 1mm Thick Aluminium Sheet Cladding Complete As Required.(d) Supply, Installation, Testing And Commissioning Of Amf Autostart Complete With Necessary Relays Like No Volt Relay, Over Voltage And Low Voltage Relays, Contactors, Timer, Pressure Switch Etc As Required For The Auto Start Of The Diesel Engine In Case Of Power Failure Complete With All Accessories Including Connection To Diesel Engine Complete As Required All In Conformity With The Local Fire Regulations. The Diesel Engine Driven Fire Pump Will Start Automatically In The Event Of Pressure Drop Beyond Preset Limit Or On Mains Failure Or Failure Of Electric Driven Pumps To Start.(e) Common Bed Plate Of Fabricated Mild Steel Channel Or Cast Iron Type, Coupling, Coupling Guard Etc As Required., (f) Foundation / Plinth / Base: Shall Be Provided As Per Manufacturers Recommendations, However Minimum 0.5 M Space Shall Be Available All Around The Set And Height Of Plinth Shall Not Be Less Than 0.3 M(g) Diesel Storage Tank Of Capacity Adequate For Storage Of Diesel As Per Manufacturer Specification. (viii) Fully Automatic Ac Operated Additional Battery Charger Of Suitable Capacity Incuding Suitable Size Twin Core Copper Wires Fixed With Copper Lugs Shall Be Provided From Charger To Battery For Charging Of Batteries Without Any Extra Cost To The Government.(h) Misc: Tool Kit, Operation And Maintenance Catalogue, Spare Part List, Overhauling Manuals, Guarantee Card Etc Shall Be Provided As Per Manufacturer Standard Practices., Supplying And Laying Synthetic Rubber Insulated Mats Of Size 2m X 1m X 2.0 Mm Thick, For Voltage Upto 3.3 Kv For Electrical Purpose As Per Is 15652-2006, (superseding Is 5424) Iec / Bs En 61111: 2009 Bis / Erda / Cpri Approved, Suitable For Electrical Shock Safety, Complete All As Specified And As Directed By The Engineer-in-charge At Site., S&f Pressure Switch, Fixed In Water Rising Line, Univeral Type, Including All Necessary Wiring Using Suitable Size Of Wire, Complete All As Specified And As Directed By The Engineer-in-charge At Site., Material And Labour For Ms Studs, Nuts And Bolts Of Any Size And Any Length With Suitable Mild Steel Washer Of Any Size For Jointing Of Flange Pipes / Valves / Glands Etc, Complete All As Specified And As Directed By The Engineer-in-charge At Site., Supply And Fixing In Repairs, Ci Fittings Such As Bends (any Type, Radius And Angle) Tapers Any Type, (straight, Bend, Increasing, Decreasing Or Double Socket Etc.) Tee, Branch Pieces Single Branch. "y" Junction, Double Branch, Cross (all Sockets Or Socket And Spigot) Collars, Caps And Plugs, Suitable For Spigot & Socketed Pipes / Flanged Pipes, Complete All As Specified And As Directed By The Engineer-in-charge At Site., Material & Labour In Repairs, For Earthing Complete With Copper Earth Plate Electrode Of Size 60cm X 60cm X 3.15 Mm, Buried Directly In Ground, Vertically, At A Depth Not Less Than 2.25 Mtr Below Normal Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Mtr Below Normal Ground Level, Surrounded From All Sides By 15cm Thick And Packed Layer Of Charcoal Dust And Common Salt Filling In Alternate Layers Etc And Connected To And Including Copper Strip Of Size 20x3 Mm As Earth Lead Upto 7.5 Mtr By Means Of Bolts, Nuts, Check Nuts And Washers Made Of Galvanised Iron And Protected By Light Grade 40 Mm Bore Gi Pipe Connected To Main Control Board And Gi Pipe Medium Grade 20mm Bore For Watering And Including Funnel, Wire Mesh, Charcoal Salt Etc Rcc Pit Cover Flush To Earth Pit 50mm Thick Reinforced With 8mm Tmt Bar 100mm C/c And Pcc Chamber Pit With Pcc (1:3:6) Type C1 (using 20mm Graded Stone Aggregate) Including Excavation And Earth Work Disposal Of Surplus Soil To Distance Not Exceeding 50 Metre) And Testing After Completion All As Specified And Shown On Plate No 3 Of Ssr Part I 2009. Notes:- The Rates Quoted For This Item Includes For Excavation And Earth Work In Any Type Of Strata Or Drilling Hole For Electrode, P.c.c. Pit And C.i. Cover, Funnel With Watering Pipe, Wire Mesh And Copper Lugs Etc. As Specified, G.i. Protection Pipe Of Size Specified For Protection Of Earthing Lead From Mechanical Injury Or Tempering, Test Point And Any Extra Length Of Main Earthing Lead Beyond 7.5 Metres, Connecting Lead From Test Point To Main Switch Or Switch Board Or Equipment To Be Earthed, Testing After Completion And If The Desired Earth Resistance Is Not Obtained The Earthing Will Be Redone At No Extra Cost.
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
79000.00 -
Document Cost
500.00 -
Estimated Cost
3930000.00
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054