Repairing And Renovation Works I.e. Flooring Works (part), Painting Of Truss With Shed (part) Of Existing G.c.i Vegetable Shed (20.70m X 9.35m) And Colour Wash, Painting Of Wooden Shutter 16 Nos. Existing Shop At Hatbele Hat
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
BOQ Items Total Items : 23 | Total Qty : 2433.005
# | Item | Quantity | Units |
---|---|---|---|
1 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.(a) In ground floor including roof. In ground floor | 5.580 | Cum |
2 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall beconsidered for payment] | 20.400 | Sqm |
3 | Ordinary Cement concrete [ Mix 3 : 1.5 : 1 ] with graded stone chips(20 mm.size) excluding shuttering and reinforcement, if any, in ground floor.as per Is Codes. a) Pakur Variety. | 7.749 | Cum |
4 | Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) . (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work. i) Ground Floor | 79.1200 | Sqm |
5 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (i) Tor steel/Mild steel. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. | 0.730 | MT |