Tender for PUBLIC HEALTH ENGINEERING DEPARTMENT - NTID 31324737
PUBLIC HEALTH ENGINEERING DEPARTMENT
Kalyani, West Bengal, India
NTID 31324737
- Opening Date : Mon 10th April, 2023
- Closing Date : Fri 7th April, 2023
- ₹ 2133930.00
- NTID 31324737
Repair Of 350 Cum Capacity Over Head Reservoir, Painting Of Boundary Wall Of Head Work Site, Pump House And Airp At Joypur Ws Scheme In Hanskhali Block Under Nadia Arsenic Division - I P. H.e. Dte
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
42679.00 -
Document Cost
250.00 -
Estimated Cost
2133930.00
BOQ Items Total Items : 34 | Total Qty : 15100.45
# | Item | Quantity | Units |
---|---|---|---|
1 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concerte by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris fron site complete as per direction of the Enginer-in-Charge. | 150.0000 | sqm. |
2 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush and applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two coats of polymer modified anti corrosive protective coating formulated to inhibit the corrossion of reinforcement as per manufacturer's specification. | 130.0000 | sqm. |
3 | Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in population (1 bonding agent : 4 water : 6 cement) as per manufacturers specification | 150.0000 | sqm. |
4 | Applying epoxy based reactive jointing the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 kg /m2 of concrete surface). | 150.0000 | sqm. |
5 | Controlled cement concrete with wel graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS:456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in-charge. Consumption of cement will not be less than 300 kg of cement with Super plasticiser per cubic meter controlled concrete but actual consumption will be determind on the basis of prellminary test & job mix formula. ( Using Concrete Mixer.) M 30 Grade Pakur Variety From Heel beem to top of reservoir. | 5.0000 | cum |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane