ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry Now
8534- Repair Maint And Atten, PORT BLAIR - Tender Details
Explore tender information for 8534- Repair Maint And Atten in PORT BLAIR, including eligibility, deadlines, and bid specifics.
Military Engineer Services
PORT BLAIR, Andaman and Nicobar Islands, India
NTID 39303645
Opening Date : Wed 5th March, 2025
Closing Date : Tue 4th March, 2025
- ₹ 4950000.00
- NTID 39303645
8534- Repair / Maint And Attending Water Supply Complaints For Leakages / Blockages Of Pipe Line And Raising Main Pipe Line, Valve Pit Chambers, Sluice Valves, Gate Valves And Ball Valves And Its Connected Works Maint Of Command Swimming Pool, Rain
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
99000.00 -
Document Cost
500.00 -
Estimated Cost
4950000.00
BOQ Items Total Items : 177 | Total Qty : 3983.5
# | Item | Quantity | Units |
---|---|---|---|
1 | M&L for attending break down, execavation and earthwork in mud/soil by using earthmoving machinery (Hitachi)/labour to a length of 10 m approx (from chouldhari to Minniebay Pump House) and depth upto 3 Mtr and forming bund with excavated Hard/soft soil to avoid sea/raw water entering into the working area including pumping/bailing out water by using portable diesel engine driven pumpset complete all as directed and including the following :- (i) Cutting of CI/DI pipe of size upto 400/350/300 mm dia after thorough inspection for the damage incl bailing out water using portable pumpset. (ii) Taking out CI/DI pipe after removing from tyton joints at both ends with the help of Hitachi and keeping aside for further disposal. (iii) Transporting CI/DI pipe of size upto 400/350/300 mm dia to the site from Chouldhari dam or any area as directed by Engr-in-Charge, cutting the pipe into two pieces as per requirement and laying into the trenches using machinery. (iv) Jointing by using rubber tyton rings upto 400/350/300mm dia pipe to the corresponding socket and spigot ends of the existing pipeline after aligning the pipe line as per site condition, inserting the CI collar of size 400/350/300 mm dia complete all as directed. (v) CI/DI special will be measure separately in respective item | 1.00 | Each Job |
2 | All as per Item No.1.00 above but depth above 3 Mtr all as directed by Engineer in Charge Note : (i) The rate is deemed to include cost towards tools and plants and transportation required for attending the repair work. (ii) The rate deemed to inclusives of soil additional required to refilling/ making bunds to prevent sea water entering into the work place complete. (iii) The cost of pipes, specials, Tyton/lead joints shall be measured and paid seperately under relevent item of this schedule. | 1.00 | Each Job |
3 | M&L for detecting and repairing leakage in CI/DI pipe lines of size 250/200 mm bore, taking up unserviceable /serviceable CI/DI water main with spigot and socket ends (including fittings) of any type/grade and joints from trenches and layingnew CI/DI pipe lines of size 300 mm bore in trenches or placing on existion pillers /supports as directed to perform the following activities :- | 2.00 | Each job |
4 | (a) Execution and earth work in soil / mud by using machinery/labour to suitable length (Appx 10 mtrs) and forming bund with excavated soil to avoid sea / row water entering into the working area including pumping/bailing out water by using portable desal engine driven pump set. (b) Cutting of CI / DI pipe of size 200 mm bore after through inspetion for the damaged pipe line including disconnecting / dismentling. (c ) Taking out CI/DI pipewith CI/DI specials after removing from joints/burning out joints and removing lead at both ends with the help of hydrolic crane other machinery and keeping aside fr further disposal. (d) Cutting of new pipe into pieces as per rquirement and laying using machinery. ( e) Alinging the pipe line as per sie condition, in setting the Collar suitable for 200 mm CI/DI pipe. (f) Attending repair work within the minimum time frame/period as specified by Engr - in - charge. Notes for the Items i) The unit rate is deemed to include cost of tools and plants and transprtation required for attending the repair work. ii)Supply only CI/DI pipe shall be measured & paid for seperately under relevant item of this schedule. iii) Extra soil required for refilling /making bunds to prevent water entering into the work place shall be deemed to include in the unit rate. iv) Specials / rubber or fiber/ lead joints shal be measured and paid for seperately under relevent items of this schedule. v) Old unsv CI/DI pipes, fittings, lead, nuts, bolts, washer, gaskets etc. shall become contractors property and necessary recovery as per schedule of credit shall be deducted from contractor. | ||
5 | All as per item No:3.00 here-in - before but for CI/DI pipe line of size 80/100/150mm | 3.00 | Each Job |