Tender for Jawaharlal Institute Of Postgraduate Medical Education And Research - NTID 25202929
Jawaharlal Institute Of Postgraduate Medical Education And Research
Puducherry, Tamil Nadu, India
NTID 25202929
- Opening Date : Wed 1st September, 2021
- Closing Date : Mon 30th August, 2021
- ₹ 0.00
- NTID 25202929
rate contract for supply of consumables and non consumables for the department of neonatology for 2021 22 - intravenous line, extension 10 cm double lumen, 26g peripheral i.v cannula, neonatal nasogastric tubes with number markings size 5f specifications;a. soft materialb. maximum length-, neonatal nasogastric tubes with number markings size 7fspecifications;a. soft materialb. maximum length-, neonatal nasogastric tubes with number markings size 8fspecifications;a. soft materialb. maximum length-, peripherally inserted central venous catheter with indroducer, 1f, 28g specifications:a) peelable cannulab)should not be more than 30 cm longc) polyurethane/silicone material, peripherally inserted central venous catheter with indroducer 2f / 24g specifications:a) peelable cannulab)should be not more than 30 cm longc) polyurethane/silicone material, peritoneal dialysis catheter (infant), peritoneal dialysis drainage set, urine mutli reagent (albumin /glucose / ketone/ nitrite) strips, c reactive protein bedside latex agglutination diagnostic kit, micro esr tube (capillary tube) heparinized specifications:1) should withstand centrifuge of 5000 rpm for 5 minutes2) inner diameter of atleast 1.2 mm3) length of atleast 75 mm, umbilical catheter single lumen 3.5 f, umbilical catheter single lumen 5 f, umbilical catheter double lumen 5f, disposable neonatal ventilator circuit compatible with bella vista ventilator specifications:1)should have heater wire in both limbs2) should be single-use neonatal size tubings3)build quality should be good, without leaks or loose connections, breathing circuits for fisher & paykel neonatal heated high flow, devicespecifications:1) auto-fill humidification chamber compatible with f&p mr850 humidifier2) the circuit tubings should be kink proof3)should include pressure-relief valve and pressure-monitoring port4) tube connecting the nasal cannula to the rest of the circuit should be flexible and allow free movements of the neonate's head5) should have heater wire, disposable breathing circuits for fisher & paykel neonatal heated humidified cpap devicespecifications:1) should be single-use tubings compatible with fisher & paykel neonatal heated humidified cpap device2)should include auto-fill humidification chamber compatible with f&p mr850 humidifier3) should include heater wire, endotracheal tube with secondary lumen (for surfactant administration)- size 2.5, endotracheal tube with secondary lumen (for surfactant administration)- size 3, cuffed endotracheal tube size 3mm, cuffed endotracheal tube size 3.5mm, intercostal drainage tube with/withour trocar 8 f, intercostal drainage tube with/without trocar 10 f, glucometer battery, 3v standard coin shaped lithium battery, cling wrapspecifications:1) food grade plastic wrap2) minimum breadth of 30cm, hydrocolloid sterile skin dressing specifications:1) water proof material2)15x15 cm, polyurethane based silicone adhesive tape specifications:1) waterproof2) non-allergeanc3)can be reapplied without loss of adhesiveness4) 2x1 inch size approximate., neonatal ecg skin electrodes, disposable bacterial expiratory filter for ventilator, arterial blood gas capillary tubesspecifications:1)made of heavy-walled glass, with fire polished ends2) sodium-heparinized3) compatible with siemens rapidlab 348 abg machine4) provided with end caps and mixing wire 5) transparent 6) volume-100-200 micro litre, phototherapy eye maskspecifications:1)single piece wrap around design with velcro for adjustment of tightness of fit2) three sizes-small, medium, large, reusable belt type neonatal spo2 probes compatible with nellcor covidien spo2 monitor, disposable belt type neonatal spo2 probes compatible with nellcor covidien spo2 monitors, reusable belt type neonatal spo2 probes compatible with nellcor oximax n600x spo2 monitor, disposable belt type neonatal spo2 probes compatible with nellcor oximax n600x spo2 monitors, reusable belt type neonatal spo2 probes compatible with masimo radical 7 spo2 moniotr, disposable belt type neonatal spo2 probes compatible with masimo radical 7 spo2 monitor, reusable belt type neonatal spo2 probes compatible with masimo rad 97 spo2 moniotr, disposable belt type neonatal spo2 probes compatible with masimo rad 97 spo2 monitor, reusable belt type neonatal spo2 probes compatible with masimo spo2 monitor inbiult in phoenix open care system cic 101, resuable neonatal t-piece resuscitor tubings with mouth piece compatible with nice neotech 5020 hornpuff infant resuscitator, resuable neonatal t-piece resuscitor tubings with mouth piece and pressure monitoring line compatible with nice neotech 5020 hornpuff infant resuscitator, single use flow generator (interface for connecting nasal cpap mask) to the circuit, invasive bp monitoring line transducer with cable compatible with schiller multipara monitor, non consumables, non invasive blood pressure cuff (new born) size 4-6 cm disposable compatible with schiller monitorsspecifications:1) should be reusable2) should be compatible with multiparameter monitor, non invasive blood pressure cuff (new born) size 6-11 cm dispoable compatible with schiller monitorsspecifications:1) should be reusable2) should be compatible with multiparameter monitor, non invasive blood pressure cuff (new born) size 1-4 cm compatible with schiller monitorsspecifications:1) should be reusable2) should be compatible with multiparameter monitor, non invasive blood pressure cuff (new born) size 4-6 cm resuable compatible with schiller monitorsspecifications:1) should be reusable2) should be compatible with multiparameter monitor, non invasive blood pressure cuff (new born) size 6-11 cm reusable compatible with schiller monitorsspecifications:1) should be reusable2) should be compatible with multiparameter monitor, neubauer’s cell counting chamber (for rbc & wbc counting), neonatal nasal cpap mask, small sizespecifications:1) compatible with phoenix radiant warmer cpap machine2) comes along with the connecting interface and bonnet 3) interface is made of flexible tubes which connects interchangeably with prongs allowing free head movements 4) soft and plaible material with optimum fit and sealing capability, neonatal nasal cpap mask medium size (one per pack)specifications:1) compatible with phoenix radiant warmer cpap machine2) comes along with the connecting interface and bonnet 3) interface is made of flexible tubes which connects interchangeably with prongs allowing free head movements 4) soft and pliable material with optimum fit and sealing capability, neonatal nasal cpap mask, large size (one per pack)specifications:1) compatible with phoenix radiant warmer cpap machine2) comes along with the connecting interface and bonnet 3) interface is made of flexible tubes which connects interchangeably with prongs allowing free head movements 4) soft and pliable material with optimum fit and sealing capability, neonatal nasal cpap prongs, small size specifications:1) compatible with phoenix radiant warmer cpap machine2) comes along with the connecting interface and bonnet 3) interface is made of flexible tubes which connects interchangeably with masks allowing free head movements 4) soft and plaible material with optimum fit and sealing capability, neonatal nasal cpap prongs, medium size specifications:1) compatible with phoenix radiant warmer cpap machine2) comes along with the connecting interface and bonnet 3) interface is made of flexible tubes which connects interchangeably with masks allowing free head movements 4) soft and pliable material with optimum fit and sealing capability, neonatal nasal cpap prongs, large size specifications:1) compatible with phoenix radiant warmer cpap machine2) comes along with the connecting interface and bonnet 3) interface is made of flexible tubes which connects interchangeably with masks allowing free head movements 4) soft and plaible material with optimum fit and sealing capability, nasal cannula for high flow nasal oxygen-preterm neonatal sizespecifications:1) kink-proof and crush-resistant tube 2)adhesive pads to secure cannulae on cheeks3)max. flow rate 8 l/min4)swivel connection5) should be compatible with breathing circuits for fisher & paykel neonatal heated humidified high flow nasal device6) quote should include the cost of 10 adhesive pads for each cannula, nasal cannula for high flow nasal oxygen-term neonatal size specifications:1) kink-proof and crush-resistant tube2) adhesive pads to secure cannulae on cheeks3) maximum flow rate 8l/min4) swivel connection5)should be compatible with breathing circuits for fisher & paykel neonatal heated humidified high flow nasal device6) quote should include the cost of 10 adhesive pads for each cannula, infant bonnet (size 17-22cm) compatible with fischer and paykel bubble cpap machine, infant bonnet (size 22-25 cm) compatible with fischer and paykel bubble cpap machine, infant bonnet (size 25-29) compatible with fischer and paykel bubble cpap machine, infant bonnet (size 29-36) compatible with fischer and paykel bubble cpap machine, heater wire adaptor and temperature sensor probe compatible with fischer & paykel mr 850 humidifier base and disposable fischer & paykel neonatal ventilator circuit specifications 1) both 2 and 3pin adaptor in the inspiratory limb, heater wire adaptor and temperature sensor probe compatible with ggm humidifier base and disposable fischer & paykel neonatal ventilator circuit, heater wire adaptor and temperature sensor probe compatible with f&p ventilator humidifier base and reusable sle neonatal ventilator circuit, heater wire adaptor and temperature sensor probe compatible with bella vista humidifier base and reusable bella vista neonatal ventilator circuit, heater wire adaptor and temperature sensor probe compatible with bella vista humidifier base and disposable bella vista neonatal ventilator circuit, heater wire adaptor and temperature sensor probe compatible with phoenix cpap(ncpap 300) machine, skin temperature probe compatible with phoenix cic 101 radiant warmer, laryngoscope set: fibreoptic (neonatal)specifications:, should be reusable and made of good quality metal2) each set should have miller (straight) blades of atleast 3 sizes, 00,0,1): one blade of each size per set3)each set should have a handle for neonatal use4) fibreoptic light source5) including battery, autoclavable silicon self inflating resuscitation bag with safety valve- neonate (250 ml) specifications:, should be reusable and autoclavable2) should have oxygen reservoir3) should have a robust safety pressure release valve (pop off valve) for pressure >40 cm h2o4) inlet outlet and expiratory valves should be durable without leaks5) equipment should be able to withstand a fall from a height of 5 feet6) should have a facility for attaching a peep valve (desirable), autoclavable silicon self inflating resuscitation bag with safety valve- pediatric (500 ml) specifications:, should be reusable and autoclavable2) should have oxygen reservoir3) should have a robust safety pressure release valve (pop off valve) for pressure >40 cm h2o4) inlet outlet and expiratory valves should be durable without leaks5) equipment should be able to withstand a fall from a height of 5 feet6) should have a facility for attaching a peep valve (desirable), double breast pump accessories set specifications:, compatible with medela lactina select electric breast pump2)should have one syringe, 2 breast shields, 2 connectors , 2 tubes and, bottles, membrane compatibel with medela symphony double breast pump, piston compatible with medela lactina electric plus breast pump, nasal prongs- infant sizespecifications:, length of the connecting tube from the prongs should not be more than 20 cm2) the distance between the two prongs should be suitable for use in newborns3) soft material, nasal prongs- pediatric size specifications:, length of the connecting tube from the prongs should not be more than 20 cm2) the distance between the two prongs should be suitable for use in newborns3) soft material, infantometerspecifications:, sleek broad acrylic base with one sliding side adjustable as per length of baby, dual scale for direct reading in cms / inches upto 90cm., folding sides for easy storage, baby can comfortably lay on the chest of the scale., stethoscopespecifications:, should be appropriate for pediatric use with pediatric size diaphragm and bell2) should have good quality tubing of at least 40 cm length3) the earpieces should be soft and provide a good seal, digital hand held luxmeter specifications- 1) portable 2) measure field with auto-change scale(, 1999 micro watt/cm2) 3) frequency field 400-500 nm 4) work temperature 0-50 degree c 5) humidity 0-95% 6) backed by 9 v battery 7) autonomy 300 hours 8) provision of signal of low battery, provision for data hold button 10) lcd contrast display 11) zero adjusting by push button switch 12) leather case to hold the equipment, observation lamp compatible with phoenix open care radiant warmer with cic 101specification:1) 12 v 50 w, observation lamp compatible with phoenix open care radiant warmer with noc 100specification:1) 12 v 50 w2) led type, ir lamp compatible with phoenix open care radiant warmer with, 101, end bushcompatible with phoenix open care radiant warmer with, 101, rectal temperature probe compatible with schiller multipara monitor, centrifugespecifications:1) should be able to spin a minimum of 16 capillary hematocrit tubes at the same time for measurement of hematocrit and for plasma separation for other investigations.2) should be supplied with rotor for microhematocrit (capillary tubes)3) maximum speed at least 10,000 rpm. increments should be at 1000rpm or smaller.4)led display of rpm5)smooth start and stop. 6)should be able to set spin time in the range of 1 to 15 minutes or longer in 1-minute increments. a “hold” or “continuous” mode is preferable.7)maximum noise level 60dba8)ambient operating temperature: 4 to 40 degrees c9)secure, safe lid to prevent accidental opening during centrifugation should be present.10)the equipment should be brought for demonstration at jipmer nicu on request. if not, the quotation, be rejected, cfl lamps compatible with 4000 cfl neotech phototherapy machine, o2 cell compatible with phoenix open care system cic 101, cpap chamber compatible with f&p cpap machine, set of belts (teslon & nylon belt compatible with sealing machine) model - frb7701, sound level meter: specifications- 1) portable 2) lcd display 3) measurement range, 130 db 4) resolution 0.1db 5) frequency 30-8000 hz 6)should have range selector e.g. 30-80db, 50-100db, 0-130db 7) electric condenser microphone type 8) should work both on power and rechargable battery 9) low battery indicator 10) should provide power adapter, charging 11) leather cse to hold the equipment, cold lightspecifications:1. should consist of a light source and a flexible fibreoptic cable.3. should output high intensity white light adequate to visualize upper limb arteries in term neonates when transilluminated at the wrist.4. fibreoptic cable should be longer than 60 cm.6. the system should be compact and light-weight and portable.7. should not heat patient skin or tissues or cause burns when used for 5 minutes for transillumination.8. should come with ac current adapter for 220-240v., non stretchable head circumference measuring tape, thermal reflector for temperature probe (neonatal size), ultrasonic nebulizer machinespecifications:1.should be light weight, portable, compact and easy to use.2 frequency of ultrasonic generator should be greater than 1.5 mhz3 should have 3 speed nebulization rate control ( minimum, medium, maximum)7 should uses water as ultrasonic conduction medium8 should provide silent operation.9 should have a built in timer and shuts off after 10 minutes use10.should be provided with a complete nebulisation kit and medication cup – 5 nos
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
Refer Documents -
Document Cost
590.00 -
Estimated Cost
Refer Documents
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane