Tender for Jawaharlal Institute Of Postgraduate Medical Education And Research - NTID 25108268
Jawaharlal Institute Of Postgraduate Medical Education And Research
Puducherry, Tamil Nadu, India
NTID 25108268
- Opening Date : Fri 20th August, 2021
- Closing Date : Wed 18th August, 2021
- ₹ 10000000.00
- NTID 25108268
Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Neurosurgery For 2021 22 - Aneurysm clip: Yasargil type, Titanium max. Opening 7mm force 180 grams, Blade length 9mm ,straight, permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 7mm force 180 grams, Blade length 9mm ,Curved, permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 7.8mm force 180 grams, Blade length 11mm,straight permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 7.8mm force 180 grams, Blade length 11mm,curved permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 5.7mm force 200 grams, Blade length 7mm, straight permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 5.7mm force 200 grams, Blade length 7mm,curved permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 3.3mm force 110 grams, Blade length 3mm, straight , permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 4mm force 110 grams, Blade length 5mm straight, permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 9.2mm force 280 grams, Blade length 15mm,straight permanent , Aneurysm clip: Yasargil type, Titanium max. Opening 9.2mm force 280 grams, Blade length 15mm,curved permanent , Aneurysm clip: Yasargil type, Titanium (steel component if titanium is not available with any manufacturer) Sundt graft type vessel wrapping clip 7 mm. This has a dacron type fabric built into the clip to cover a vessel tear. , Aneurysm clip: Yasargil type, Titanium, fenestrated permanent clip - Straight 7 mm , Aneurysm clip: Yasargil type, Titanium, fenestrated permanent clips straight, 9 mm, , Aneurysm clip: Yasargil type, Titanium, fenestrated permanent clips curved 7 mm, , Aneurysm clip:Yasargil type, Titanium, fenestrated permanent clips right angle 9 mm , Aneurysm clip:Yasargil type, Titanium, fenestrated permanent clips, straight, 11 mm , Aneurysm clip: Yasargil type, Titanium, fenestrated permanent clips, straight, 13 mm , Aneurysm clip: Yasargil type, Titanium,fenestrated permanent clips, straight, 17 mm , Aneurysm clip: Yasargil type, Titanium,permanent clips right angle 9 mm right to left , Aneurysm clip: Yasargil type, Titanium, permanent clips right angle 9 mm right to right , Aneurysm clip Yasargil type, Titanium, 3 mm size for use in arteriovenous aneurysm surgery (permanent, mini clips) , Ultrashort fenestrated (fenestration 5mm or 3 mm as will be mentioned in purchase order) "nub clip". (yasargil type , titanium) , Reinforcing booster clip, Yasargil , Aneurysm clip, Yasargil type, permanant. Quote a uniform rate for a single clip. The exact dimensions and configuration will be informed at the time of purchase order. To reduce complexity of selection, this will be the preferred method of selection. , Aneurysm clip, Yasargil type, temporary. Quote a uniform rate for a single clip. The exact dimensions and configuration will be informed at the time of purchase order. To reduce complexity of selection, this will be the preferred method of selection. , Sugita type aneurysm clip (titanium or permanent) (Low profile spring, Sugita bridge wire system, and channel in blade) Quote a uniform rate for a single NON-fenestrated clip. We will inform the clip size and shape at the time of purchase oder , Sugita type aneurysm clip (titanium or permanent) (Low profile spring, Sugita bridge wire system, and channel in blade) Quote a uniform rate for a single fenestrated clip. We will inform the clip size and shape at the time of purchase oder , Sugita clips with tapered design with atraumatic groove with laser etched lot number for identification. Clip should be made of non-ferromagnetic titanium alloyal verified by ASTM F136 '/ ISO 5832-3 for compatiblity with 3 Tesla MRI. Quote for a uniform rate for a single non-fenestrated clip. We will inform clips size and shape at the time of purchase order. , Sugita clips with tapered design with atraumatic groove with laser etched lot number for identification.Clip should be made of non-ferromagnetic titanium alloyal verified by ASTM F136 '/ ISO 5832-3 for compatiblity with 3 Tesla MRI Quote for a uniform rate for a single fenestrated clip. We will inform clips size and shape at the time of purchase order. , Perneczky type Aneurysm Clip. Quote a uniform rate for a single non fenestrated clip. We will inform the clip size and shape at the time of purchase oder , Perneczky type Aneurysm Clip. Quote a uniform rate for a single fenestrated clip. We will inform the clip size and shape at the time of purchase oder , Aneurysm clip - T type (Titanium,permanent) , Bulb for OT Lights (Halogen - compatible with Maquet'/Dr.Lite over head lights) , Acrylic cement Polymethylmethacrylate medical grade dental cement for cranioplasty in powder form which polymerizes and sets with addition of liquid polymerizing agent with adequate time for molding into shape during surgery. All components should be sterilizable by appropriate means in its own containers. Each pack should contain at least 50 gms. , Transparent cannula site dressing Transparent polyurathane, impervious to bacteria, but permeable to water vapor maintaining transparency. Self adhesive (10X12 cm) with a chlorhexidine gluconate gel layer (3X4 cm) and IV line securing adhesive strip and label. , Transparent cannula site dressing Transparent polyurathane, impervious to bacteria, but permeable to water vapor maintaining transparency. Self adhesive (10X12 cm) , Odourless hydrocolloid dressing with water resissnt film border and an outer barrier film 15 cm X 15 cm , Abosorbant clear acrylic dressing which should be three layered with a top layer of breathable (letting oxygen and vapour) film , middle layer of acrylic polymer and a perforated bottom layer and adhesive. Size 16 cm X 19 cm , Abosorbant clear acrylic dressing which should be three layered with a top layer of breathable (letting oxygen and vapour) film , middle layer of acrylic polymer and a perforated bottom layer and adhesive. Size 11 cm X 12.7 cm , Foam dressing for sacral and other pressure sores Four layer dressing with outermost breathable film, moisture control layer and a absorbant layer 10 X 10 cm , Compression dressing with acrylic adhesive which does not irritate skin . 10 cm X 4 meters (non-stretched dimension) , Thromoembolism stocking Lycra containing thromboembolism prevention stocking, thigh to ankle level, various sizes for patients in ICU, immobile patients. It should have graduated pressure fit. Snug fit. Exact number of each sizes will be mentioned at the time of purchase order , Silk like cloth tape with strong adhesive 1.25 cm x 9 meters , Silicone adhesive tape which is painless to remove from the skin . Size of 2.5 cm x 1.3 m , Silicone adhesive tape which is painless to remove from the skin . Size of 5 cm x 1.3 m , Artificial dural graft Non-biological '/ synthetic, biocompatible, implantable, artificial dural graft. Sewable to normal dura. Should be impervious to fluid. For permanent implant. Should lead to minimal adhesion formation and tissue reaction. Expanded polytetrafluoroethylene (ePTFE) preferred. , Artificial dural graft Non-biological '/ synthetic, biocompatible, implantable, artificial dural graft. Sewable to normal dura. Should be impervious to fluid. Material should be absorbable (like poly L lactic acid) and biomimetic microstructure for tissue regeneration. For permanent implant. Should lead to minimal adhesion formation and tissue reaction. , Reactive polymer based multilaminate adhesive film for protecting dural suture line from CSF leak, which is biocompatible and slowly resorbed. Should adhere to dural surface by electrostatic interaction. 60 X 60 mm size, sterile ready to use. , Reactive polymer based multilaminate adhesive film for protecting dural suture line from CSF leak, which is biocompatible and slowly resorbed. Should adhere to dural surface by electrostatic interaction. 60 X 80 mm size, sterile ready to use , Soft nasal pack with breathing hole after endoscopic nasal surgery (polyvinylalcohol material) , Soft nasal pack without breathing hole after endoscopic nasal surgery (polyvinylalcohol material) , Foley catheter with antibacterial coating of gold, palladium and silver which should act by virtue of a galvanic effect inhibiting biofilm formation. Silicone . [100% pure silicone, 2 way bulb] Exact sizes and quantities required will be mentioned at the time of purchase order and hence please quote a uniform price for all available sizes ranging from 6F to 18 F. The product should have randomized controlled data to show that it reduces urinary tract infection , Foley catheter with antibacterial coating of gold, palladium and silver which should act by virtue of a galvanic effect inhibiting biofilm formation. [Latex with 2 way bulb] Exact sizes and quantities required will be mentioned at the time of purchase order and hence please quote a uniform price for all available sizes ranging from 6F to 18 F. The product should have randomized controlled data to show that it reduces urinary tract infection , Silicone balloon catheter for Intracranial neuroendoscopy 3 or 4 F (Fogarty catheter) , Neurosurgical patties Sterile, ready to use cotton patties, in sterile packaging. Size 7x2 cm, each pack should contain at least 10 patties , Neurosurgical patties silicone transparent, threaded radio-opaque. , Neurosurgical cottonoids, sterile, ready to use cottonoids with visible [preferably black] tails of different sizes in ready to use sterile packs , Perforator with plunge guard (single use, disposable) Perforator with inherent mechanism to stop a plunge once dura is reached. Should be compatible with Hudson's brace available in JIPMER. If not, you must provide a compatible Hudson brace for every 100 units placed. , Perforator with plunge guard (Reusable, Sterilizable) Perforator with inherent mechanism to stop a plunge once dura is reached. Should be compatible with Hudson's brace available in jipmer, otherwise brace to be provided free of cost for every hundred units placed. , Ventriculoperitoneal shunt [Adult size, Pressure: High'/Medium'/Low] Burr hole design of chamber and valve with diaphragm type valve. Chamber should sit on the burr hole which allows aspiration of CSF if required. Biocompatible material. The part that is placed on the burr hole should have a low profile (very important). Valve seating interface of dissimilar polymers. Valve seating interface of dissimilar polymers (Will be rejected if it is not a burr hole design or if the chamber is not low profile) Exact quantities of High'/ medium or low pressure ones needed will be told at the time of purchase order , Ventriculoperitoneal shunt [medium pressure, pediatric size] Burr hole design of chamber and valve with diaphragm type valve. Chamber should sit on the burr hole which allows aspiration of CSF if required. Biocompatible material. Medium opening pressure. Pediatric size. . The part that is placed on burr hole should have a low profile(very important). Valve seating interface of dissimilar polymers , Ventriculo-atrial shunt [medium pressure, adult size] Burr hole design of chamber and valve with diaphragm type valve. Chamber should sit on the burr hole which allows aspiration of CSF if required. Biocompatible material. The part that is placed on the burr hole should have a low profile (very important). Valve seating interface of dissimilar polymers , Ventriculoperitoneal shunt antibacterial [medium pressure, Adult '/ Paediatric size] Antibacterial agents should be incorporated within substance of the shunt material [not coated] which elutes to the outside of the shunt as well as within lumen to reduce chances of shunt infection; Two different antibiotic agents should be impregnated. , Ventriculoperitoneal shunt with an antisiphon device built into it (two ball design) , Ventriculoperitoneal shunt with an antisiphon device built into it (three ball design) , Ventriculoperitoneal shunt with an antisiphon device built into it (four ball design) , Y connector for ventriculoperitoneal shunt which can be attached to a shunt to drain a loculation or a separate cyst , Adjustable pressure valve system with siphon control (that can be inserted into antibacterial tubing system). We should be able to adjust the valve pressure after implantation magnetically without the need for Xray confirmation. The device to adjust the pressure should be given on loan basis , Antibacterial external ventricular drainage catheter. Antibacterial agents should be incorporated within substance of the catheter which is placed in brain to drain CSF [not coated] which elutes to the outside of the catheter and within lumen to prevent infection; Two different antibiotic agents should be impregnated. Should be translucent with depth markings. , Programmable ventriculoperitoneal shunt with external programming device for use in normal pressure hydrocephalus, 10 mm pressure increment settings. Programming device should be made available in JIPMER as and when requested with 24 hour prior notice (email or phone call) , Programmable lumboperitoneal shunt with external programming device for use in normal pressure hydrocephalus, 10 mm pressure increment settings. Programming device should be made available in JIPMER as and when requested with 24 hour prior notice (email or phone call) , Microsensor transducer (single use, disposable) for monitoring intracranial pressure in the brain parenchyma (it should be compatible with available monitor in JIPMER or a monitor supplied free of cost with the reusable microsensor transducer cable) The cable should relay information electronically rather than through a hydrostatic column or fiberoptics. , Ventricular catheter and pressure transducer for ICP monitoring compatible with the above monitor (or with any available monitor in JIPMER or a monitor supplied free of cost with the ventricular catheter and pressure transducer) and microsensor cables , Single use transducer cable (parenchymal or subdural or ventricular) compatible with the ICP monitor that you have quoted in the non-consumable section. , Implantable Ommaya reservoir system Implantable ommaya reservoir system of two different sizes with ventricular catheter. Capable of tapping from reservoir percutaneously or for instilling drugs , Lumboperitoneal shunt system implantable lumbo peritoneal shunt system with Touhey needle and connectors , Lumbar drain set , External ventricular drainage system which should include ventricular catheter, connecting tubes, leak proof drainage bag with volume markings and built in csf pressure scale {in a sterile and ready to use pack.} , Gigli saw wire cutter for craniotomy Should not fray'/break on using. Sterilizable. Small round low profile loops at either end. [Identical sample should be provided before selection] , Polypropylene monofilament suture of size 8-0 with atraumatic swaged needle , double armed , Polypropylene monofilament suture of size 10-0 with atruamatic swaged needle for microvascular anastamosis , double armed , Gelatin foam for hemostasis which is hydrophilic (should be able to absorb five ml water in fifteen seconds ) appoximately 80 x 50 x 4 mm , Oxidised cellulose in fibrillar form, from natural source that has rapid bioresorption characteristics within 14 days by published clinical or animal studies), , Oxidised cellulose powder with calcium which can be applied using a applicator in a deep cavity , Gelatin in fibrillar form factor which can be placed in a cavity using forceps, ph neutral, which forms a gel and can be pulled to reposition as a gel. , Oxidized regenerated cellulose in densly knitted form with high tensile strength (should not be possible to manually tear it) for use in heavy bleeding. 7 x 10 cm , Fibrin Sealant'/Glue - Glue for use in neurosurgery to prevent CSF lead based on fibrin coagulum formed on mixing fibrinogen , thrombin and synthetic aprotinin components in easy to apply chamber and nozzle system. Dual tip syringe system and vials with sterile water for reconstitution should be part of the package. Total quantity should be at least 1 ml after generation of fibrin. Warming and stirring device should be made available in OT or on demand within 24 hours. Components, if derived from pooled or single donor human blood should be free from all known pathogens. (Any agitating'/warming device required to mix the glue should be provided during use and kept in Neurosurgery OT ) , Hemostatic activated regenerated, oxidised cellulose for intraoperative hemostasis in a powder form (3g) which can be put in an operative cavity using a sterile applicator in manually activated pump , Hemostatic, activated regenerated cellulose for intra-operative hemostasis in mesh form , Hemostatic activated regenerated cellulose for intraoperative hemostasis in fibrillar form in aluminium package to protect from heat, light and moisture. Should have US FDA or CE or equivalent Indian standards. There should be published animal or human studies for clinical efficacy. , Injectable hemostatic agent Prefilled syringe with haemostatic matrix agent for intraoperative use. , Injectable hemostatic agent Prefilled syringe with haemostatic matrix agent with human thrombin (2500 IU) and calcium chloride 5ml for intraoperative use. 10 ml syringe , Bone wax Easily squashable, bone wax for sealing bleeding bone edges, sterile and ready to use in tear open packages. Should not stick to glove. , Cervical (disc) spacer of various sizes, titanium , Artificial cervical disc implant: two-piece, articulating, metal-on-metal device, wrought type 316 stainless steel (ASTM F-138) component with ball on trough mechanism. The part which comes into contact with the vertibral end plate should be roughened. The device should have four screws with two locking screws to fix it to the vertibral bodies using an anterior cervical approach. a minimum of 10° motion off the neutral position in flexion'/extension and lateral bending, unconstrained axial rotation, and 2 mm of anterior'/posterior translation should be possible ex-vivo.The device should be approved by U.S. Food and Drug Administration (FDA). , Artificial cervical disc implant which consists of two metal (cobalt-chrome alloy ) endplates and a plastic (ultra-high molecular weight polyethylene) insert that fits between the endplates. The device should be approved by U.S. Food and Drug Administration (FDA). , Expandable cages for cervical, thoracic spine, spacers for cervical spine Titanium make Lumbar fusion cage for trans foraminal application. , Cage with integrated, angulated, locking screws for fixation after cervical discectomy. Titanium cage with big graft window. , Cervical PEEK cage with sharp teeth and large graft packing window. Should have an anatomical shape to promote maintanance of cervical lordosis. , C1 –C2 joint spacer of various sizes (Titanium) , Cannulated lag screws for odontoid fixaton , Cannulated titanium screws for C2 trans-articular fusion , Instrumentation for craniocervical junction fusion Cables for insterspiral or symmetric spinous wiring for atlas and axis and accessories for applying it [entire set] , Bone Substitutes This should be an rhBMP-2 (recombinant human bone morphogenetic protein-2) formulation combined with a bovine-derived absorbable collagen sponge (ACS) carrier. Should be FDA & DGCI APPROVED , Synthetic Bone Paste consists of pure Nanocrystalline hydroxyapatite that are less than 20 nanometers in size embedded in a matrix of sterile water, with osteoconductive properties, delivered in syringe (5cc) , Hydroxyapatitile isothermic bone substitute which can set in a wet field (10 cc) , Medical-Grade Polyporous Resorbable ceramic Granules with 15% hydroxypatite+85% beta-tricalcium phosphate. (10cc) FDA & DGCI APPROVED , Anterior Cervical Plate and screws Anterior Cervical Plate system with attached locking mechanism and choice of fixed angle screws for standard cases or variable angle screws for ease of implantation in complex cases. System should allow the surgeon the versatility of creating fixed, Variable or hybrid construct intraoperatively. Plate should be 2.5mm thick. Plate should have medial'/lateral radius of curvature and Lordotic radius of curvature. Should be Approved by US FDA & DGCI. Instrumentation should be provided for the surgeries with various screws options. Quote for the set of single level plate , four screws and two locking screws , Anterior Cervical Plate and screws Anterior Cervical Plate system with attached locking mechanism and choice of fixed angle screws for standard cases or variable angle screws for ease of implantation in complex cases. System should allow the surgeon the versatility of creating fixed, Variable or hybrid construct intraoperatively. Plate should be 2.5mm thick. Plate should have medial'/lateral radius of curvature and Lordotic radius of curvature. Should be Approved by US FDA & DGCI. Instrumentation should be provided for the surgeries with various screws options. Quote for the set of two level plate , four screws and two locking screws , Anterior Cervical Plate and screws Anterior Cervical Plate system with attached locking mechanism and choice of fixed angle screws for standard cases or variable angle screws for ease of implantation in complex cases. System should allow the surgeon the versatility of creating fixed, Variable or hybrid construct intraoperatively. Plate should be 2.5mm thick. Plate should have medial'/lateral radius of curvature and Lordotic radius of curvature. Should be Approved by US FDA & DGCI. Instrumentation should be provided for the surgeries with various screws options. Quote for the set of three level plate , fivescrews and three locking screws , MultiAxial Pedicle Screw Multi Axial Titanium Pedicle Screws with diameter range of 4.5 mm, 5.5 mm, 6.5mm and the lengths ranging from 30mm to 50 mm with buttress threaded break off set screws to secure the rod in to the head of the implant. Should be compatible with the 5.5mm rod system. US FDA & DGCI APPROVED. Instrumentation should be provided along with the Rods and various sizes of screws for the surgeries. Quote a uniform rate for a construct set of four screws and two rods. (do not quote for a single screw or rod) At the time of purchase order we will specify the scew diameter and length required. , Fenestrated Screws for Compromised Bones Cannulated Screws, with four fenestrations near the tip, Top loading for fixation in Poor'/compromised bone quality to treat trauma, tumor and degenerative pathologies. System should be compatible with 5.5mm rod and should have Break off plug mechanism to ensure better fixation. US FDA & DGCI APPROVED , Implants for Posterior Cervical Fixation Multi axial lateral mass screws compatible with 3.2mm and 3.5mm rods, up to 45 degree angulations with Index markers on saddles to easily identify the 45 degree relief notches, along with 2.5mm hex internal buttress threaded set screws. US FDA & DGCI APPROVED. Quote for a construct set of two screws and a single rod. At the time of purchase order we will specify the scew diameter and length required. , Occipitocervical Bone screws, cortical threaded with 4.5mm and 5.0mm in diameters. US FDA & DGCI APPROVED , Adjustable occipital plate for occipito cervical junction with 4mm diameter, multiple screw holes, accept 4.5mm, 5.0mm occipital bone screws and pre-contoured occipital rod and occipital adjustable rod. US FDA & DGCI APPROVED , Occipitocervical adjustable rods with 360 Degree of rotation at hinge portion of rod, with 3.5 mm diameter at superior and 3.2mm diameter at inferior. Should allow to adjust intraoperatively. US FDA & DGCI APPROVED , Occipitocervical screw connectos. Allow for six points of occipital midline fixation. Flexibility in placement on the occiput in the cephalad'/caudal directions. Accept 4.5mm and 5.0mm occipital bone screws, pre-contoured occipital rod and occipital adjustable rod, low-profile occipital fixation option. US FDA & DGCI APPROVED , Straight Rod for the posterior cervical fixation titanium with the diameter and length of 3.2x240 US FDA & DGCI APPROVED , Two connectors clip compatible with a bar and buttress threaded set screw US FDA & DGCI APPROVED , MAST Multi-Level Percutaneous multi axial cannulated screws with Diameter 5.5 mm, 6.5mm and the lengths range from 30mm to 50 mm with break off set screws to secure the rod in to the head of the implant. Should compatible with the 5.5mm rod system and MAST Technology. US FDA & DGCI APPROVED. Instrumentation should be provided along with the Rods and Various sizes of screws for the surgeries , PAK Needle - Assists surgeons with guide wire insertion, while maintaining a minimal access approach utilizing a cannulated needle (2 Needles Bevel Tips) , Lumbar Interbody: Interbody Implant for use in Posterior Lumbar interbody fusion (PLIF) or Transforaminal lumbar interbody fusion (TLIF) procedures and it should be compatible with Open, Mini or MAST technique approaches. Implants should be made of Polyetheretherketone (PEEK), convex shaped, should have tantalum markers, tooth like surface and Bullet tip. Implants should have sterile pack. Length 22mm and height 10mm with internal graft volume of 0.5cc. Should have USFDA & DGCI Approval. Posterior instrumentation should be provided at the time of surgery , Lumbar Interlaminar device for use in spinal stenosis after decompression to be deployed between lumbar spinous processes. The device should be made of titianium or similar biocompatible material and it should be FDA approved for the indication (spinal stenosis). All device specific instruments necessary for implantation should be provided on loan basis. , Halo vest Halo ring, titanium pins and vest for extended immobilization of upper cervical spine. Custom fit to be ensured as and when necessary. System should be MRI compatible with minimal imaging artifacts. Tool kit for applying and removing. Demonstration and technical assistance required. , Miniplate and screw system for fixing bone flap during craniofacial surgery. Quote for a set of a 16 hole plate (profile height 0.8 mm) with 10 self drilling screws (2.0 X 5 mm) and one emergency screw (2.3 mm X 6 mm)(self drilling nature and the ease of application to be demonstrated). Each colour coded) , Self tapping 1.5 mm screws with a conical core design. The screw should have a reinforced neck allowing improved troque transmission and easy removal. The screw head profile should not be more than 0.6 mm. , Dynamic malleable titanium mesh which can be contoured using a mesh bender. Thickness should be 0.3 mm profile height. 120 x120 mm surface area , Dynamic malleable mesh which can be contoured using a mesh bender. Thickness should be 0.6 mm profile height. 200x 200 mm surface area , Absobable polylactide-glycolide absorbable plate mesh 55X55 mm of 0.75 mm thickness and ten resorbable screws 1.7 x 4 mm in sterile packs. Kit for insertion has to be provided on loan basis , Low profile (0.5 mm) two hole 16 mm bar plate with two self drilling screws (1.5 x 5 mm), grade II titanium. One driver should be provided on loan based for the purpose of fixing the screws , Low profile (0.6 mm) two hole 12 mm bar plate with two self drilling screws (1.5 x 5 mm), grade II titanium.One driver should be provided on loan based for the purpose of fixing the screws , Low Profile Medical Grade Titanium Four hole Square plate (0.6mm Thick) with Four self drilling longer pitch Screws I1.6x4mm)'/(1.6x5mm). DCGI Approved with FDA , Low Profile Medical Grade Titanium Five hole Burr Hole plate (15mm -22 mm dia. Quote uniform rate. Exact size mix will be informed at the time of purchase order) (0.6mm Thick) with FIve self drilling longer pitch Screws I1.6x4mm)'/(1.6x5mm) and one emergecy screw (1.9x4mm) DCGI Approved with FDA , Low Profile Medical Grade Titanium Five hole Burr Hole plate with Shunt hole (15mm dia) (0.6mm Thick) with Five self drilling longer pitch Screws I1.6x4mm)'/(1.6x5mm) and one emergency screw (1.9x4mm) DCGI Approved with FDA , Low Profile Medical Grade Titanium Six hole GAP plate (0.6mm Thick) with six self drilling longer pitch Screws I1.6x4mm)'/(1.6x5mm). DCGI Approved with FDA. Quote uniform price for short, medium and long. Exact numbers of each type required will be informed after purchase order , Titanium Mesh for 120 X 120 (bendable in all directions, 0.3 mm thickness) for cranioplasty with self drilling screws (6 Nos.) Self drilling nature of the screws and the ease with which the screw can be placed should be demonstrated as this is critical. , Bone flap fixation system for fixing bone flap using titanium or similar biocompatible material with thin profile, preferably with compressing plates on both sides of burr hole. Quote for one clamp 11-16 mm. All instruments on loan basis. , Burr hole button for cosmetic occlusion of burr holes with 3 Nos. of screws , Philadelphia type neck collars with hole for ventillation through tracheostomy tube, size: large'/medium'/small (exact quantity of each size will be mentioned at the time of purchase order , Philadelphia type neck collars with hole for ventillation through tracheostomy tube, with adjustable (height) size using a mechanism built within the collar , DRAPE, ENDOSCOPY GENERAL Tiburon surgical drape fabric Absorbent impervious reinforcement, 16" x 38 1'/2" Two clear poly troughs with hook & loop closure, 11 1'/8" x 30" hook & loop cord-holding tabs Fenestration, 10" x 11" Armboard covers , Incise drape self adhesive, flexible, transparent, 1.2X1.2 m, adhesive area greater than 20X20 cm. (Transparent nature of the central part is absolutely required, or else it will be rejected) samples to be provided. , Craniotomy drape Central round integrated self adhesive transparent (not just transcluscent) area of diameter greater than 20 cm, with surrounding flange, tubing for drainge of blood and wash fluid, rest of the non-woven material of the drape should be fluid impermeable of dimensions 2X1.6 m. Capable of covering the patients’ torso. , Ventriculoperitoneal shunt drape For ventricular shunt surgery covering head to abdomen with transparent sticking operation site plastic incise drape , Laminectomy Drape Water resistant drape with central iodine impregnated transcluscent adhesive patch which can cover from head to toe for laminectomy , Iodine impregnated adhesive incise drape with paper background , Microscope drape Transparent thin sterile microscope drape for use with OH5 m720 operating microscope . The drape should fit properly[sample to be provided to assess suitability] , Microscope drape Transparent thin sterile microscope drape for use with Moller Wedel HIR700 neurosurgical operating microscope. The drape should fit properly[sample to be provided to assess suitability] , Microscope drape Transparent thin sterile microscope drape for use with F40 Leica microscope. The drape should fit properly[sample to be provided to assess suitability] , C' Arm (image intensifier) transparent sterile Drape , Universal Camera Drape 18x250 cms Telescopic Folding, Separate Tape Strip , Povidone iodine spray in canisters for preparing surgical site , Raney clips [plastic] , Liga Clips, small & medium , catheter mount for ventilator (maquet ventilator compatible) , NIBP cuff compatible with L&T starplus and galaxy multiparameter monitor (adult size) , NIBP cuff compatible with L&T starplus and galaxy multiparameter monitor (pediatric size) , NIBP cuff compatible with wipro GE B450 multiparameter monitors (double tubing) - adult size , NIBP cuff compatible with wipro GE B450 multiparameter monitors (double tubing) - pediatric size , SpO2 sensor and cable compatible with L&T starplus and galaxy multiparameter monitors , SpO2 sensor and cable compatible with wipro GE B450 multiparameter monitors , 3 lead ECG cable button ends detachable compatible with starplus, galaxy, and wipro GE B450 monitors , NIBP hose assembly compatible with wipro GE B450 monitors , Oxygen mask with connection adaptor , O2 'T' Piece , Tracheal Mask with connector , Non Invasive Oxygen mask , Bacterial Filter (compatible with Maquet Servo Ventilators in Neurosurgery I.C.U.) , Disposable channelled laryngoscope blade which is compatible with any of the video laryngoscope available in Neurosurgery department. , Burette set for pediatric IV fluid infusion , Sequential pneumatic compression stockings for use in DVT prophylaxis. The sleeve should be upto thigh starting from calf with straps to suit lower limb and various girths should be washable and reusable for a single patient. Should be compatible with the kendall pump device already available with us. , Sequential pneumatic compression stockings for use in DVT prophylaxis. The sleeve should be upto knee starting from calf with straps to suit lower limb and various girths should be washable and reusable for a single patient. Should be compatible with the kendall pump device already available with us. , Sequential pneumatic compression stockings for use in DVT prophylaxis. The sleeve, tubings and any other consumable should be compatible with the sequential compression machine that you have quoted in the non-consumable section below. , Patient warming blanket, thermally insulated silver coloured for use with warming air system adult size , Patient warming blanket, thermally insulated silver coloured for use with warming air system pediatric size , Pediatric and adult underbody warming blankets compatible with currently available warming devices or the one that is selected in the nonconsumable section. Please quote same value for both types. The number that is needed of each kind will be informed at the time of purchase. , 4-contact, strip, EEG electrode. Contacts numbered, platinum, 4mm dia with 10mm spacing between contacts, with connection systems, lead wires, safety sockets and connector blocks , 6-contact, 1x6 IOM strip EEG electrode, 6mm contacts. Platinum, 4mm dia with 10 spacing between contacts, with connection systems, lead wires, safety sockets and connector blocks , 8-contact, 1x8 IOM strip EEG electrode, 6mm contacts. Platinum, 4mm dia with 10mm spacing between contacts, with connection systems, lead wires, safety sockets and connector blocks. Should be thin and flexible, sterile, 8-10mm width , 6-contact depth EEG electrode, 4mm dia with 5mm spacing between contacts, with connection systems, lead wires, safety sockets and connector blocks , 16-contact, 2x8, single-tail grid EEG electrode , 20-contact, 2x10, double-tail grid EEG electrode , Sphenoidal EEG Electrodes: provide a less invasive method of recording brain activity in the epilepsy patient. Like all Epilepsy electrodes, spheniodal electrodes are fabricated from implant-grade platinum materials , 48 contact (6*8) grid implantable EEG electrode , 64 Contact (8*8) grid implantable EEG electrode , 40 Contact Multi-strip ltm subdural implantable EEG electrode series , 32 Contact Multi-strip ltm subdural implantable EEG electrode series , 24 Contact Multi-strip ltm subdural implantable EEG electrode series , Depth implantable stereotactic EEG (Stereo-EEG) electrode 4 contact(1*4)depth implantable EEG electrode (platinum / iridium contact) with anchor bolt cap. Ring contact size of 2 mm. Outer diameter should be 0.8 mm or less , Depth implantable stereotactic EEG (Stereo-EEG) electrode 5 contact depth implantable EEG electrode (platinum / iridium contact) with anchor bolt cap. Ring contact size of 2 mm. Outer diameter should be 0.8 mm or less , Depth implantable stereotactic EEG (Stereo-EEG) electrode 8 contact depth implantable EEG electrode (platinum / iridium contact) with anchor bolt cap. Ring contact size of 2 mm. Outer, distal diameter should be 0.8 mm or less , Depth implantable stereotactic EEG (Stereo-EEG) electrode 10 contact depth implantable EEG electrode (platinum / iridium contact) with anchor bolt cap. Ring contact size of 2 mm. Outer, distal diameter should be 0.8 mm or less , Depth implantable stereotactic EEG (Stereo-EEG) electrode 12 contact depth implantable EEG electrode (platinum / iridium contact) with anchor bolt cap. Ring contact size of 2 mm. Outer, distal diameter should be 0.8 mm or less , Depth implantable stereotactic EEG (Stereo-EEG) electrode 15 contact depth implantable EEG electrode (platinum / iridium contact) with anchor bolt cap. Ring contact size of 2 mm. Outer, distal diameter should be 0.8 mm or less , Depth implantable stereotactic EEG (Stereo-EEG) electrode 18 contact depth implantable EEG electrode (platinum / iridium contact) with anchor bolt cap. Ring contact size of 2 mm. Outer, distal diameter should be 0.8 mm or less , Guidance screw, 20 mm for stereo-EEG electrode, compatible with the electrodes mentioned above , Guidance screw, 25 mm for stereo-EEG electrode, compatible with the electrodes mentioned above , Guidance screw, 30 mm for stereo-EEG electrode, compatible with the electrodes mentioned above , Extension cable for 4 contact stereo-EEG electrode , Extension cable for 5 contact stereo-EEG electrode , Extension cable for 8 contact stereo-EEG electrode , Extension cable for 10 contact stereo-EEG electrode , Extension cable for 18 contact stereo-EEG electrode , Cleaning and lubricant solution for electric drill, based on food grade mineral oil and propellant base ("Pana spray" or equivalent). 500 ml can , Instrument lubricant concentrate, with antimicobial activity, 50ml capacity , Endotracheal tube with low pressure low volume cuff and a subglottic aspiration catheter port which should be above the cuff. The cuff should be shaped and tapered in such a way that secretions accumulate in the zone between tube and the tapered cuff to prevent microapiration. Quote for a single size. We will place the sizes and quantity of each size according to need. (sizes 6.0 to 8.5) , Tracheostomy tube with low profile low pressure cuff with an aspiration catheter port which help aspirate subglottic secretions above the level of the cuff. The cuff should be shaped in such a way that secretions accumulate in the zone between tube and cuff. The number of units of each size ( 7.0,7.5, 8.0 mainly) will be mentioned at the time of purchase order. , Percutaneous, sterile, ready to use tracheostomy set. , Balloon kyphoplasty set with kyphoplasy cement in sterile ready to use package. Should have a pressure indicating syringe with digital display. , Chlorhexidine slow release disc which can be placed at the site of indwelling vascular catheters. Should release the agent over seven days. , polytetrafluoroethylene patch 0.3 mm thickness suitable for carotid endarterectomy (7X5 cm) , Absorbable Cranial Fixation System thin profile (Craniotomy bone flap fixation) FDA approval is desirable, All necessary tools for implantation should be provided on loan basis , Cyanoacrylate microbial sealants for skin preparation prior to surgery in a disposable, sterile, single- use applicant that can cover an area of 20 X 20 cm , Bronchial Hygiene vibratory PEP therapy system : Should benefit both PEP therapy and airway vibration to mobilize pulmonary secretions and also in virtually spatial orientaion. Should allows inhalation and exhalation without removing from mouth, to be used with mask or mouth piece nebulizer. Should have pressure port with pressure indicator, tubing, mouthpiece, mask of different sizes. It should have provision for frequency adjustment. , Endotracheal and Tracheostomy cuff pressure controller to continously monitor cuff pressure within the ideal range of 20-30 cm of water. It should have a pressure feedback mechanism to increase pressure during peak inspiration. Single use, disposable, sterile , Bougie for endotracheal tube exchange (Tracheal tube introducer) , outer diameter 5.0mm length 700mm Straight tip, Reusable , Bougie for endotracheal tube introduction for difficulty airway (Tracheal tube introducer) , outer diameter 5.0mm 600mm length Coude tip, resuable , Bougie for endotracheal tube exchange (Tracheal tube introducer) , single use, outer diameter 5.0mm length 700mm Straight tip, single use, sterile , Bougie for endotracheal tube introduction for difficulty airway (Tracheal tube introducer) , single use, outer diameter 5.0mm length 700mm ,Coude tip , sterile single use, disposable , Indocyanine Green dye for microscope integrated video angiography during aneurysm clipping (example: Aurogreen® , Aurolab, Madurai, Tamil Nadu) 25 mg vials , Delta amino levulinic acid for flourescence guided microsurgical resection of gliomas , Forehead SpO2 sensor (disposable) for detecting oxygen saturation reliably in patients with low perfusion and low saturation with accuracy down to 60 %. Head band should be provided. If cables are required that should be provided free of cost on loan basis. It should have a four layers adhesive. , Monopolar hand pieces controllable by both hand piece and foot switch which is disposable (compatible with Excel, Mallis and L&T bipolar machines) , Monopolar microdissection needle with 5 micron tungsten tip for precision electrosurgery , Flexible Patient contact plate (compatible with Excel, Mallis and L&T bipolar machines), reusable. , Flexible Patient contact plate (compatible with Excel, Mallis and L&T bipolar machines), disposable. It should have a central split to prevent it coming off. Should have a foam topping for heat exchange. , Irrigating bipolar channel cleaning stylet compatible with Malis type irrigating bipolar along with cable , Monopolar diathermy reusable pencil hand piece which is compatible with Excel, Mallis, martin, and L&T diathermy machines , Skin temperature probe that has an adhesive layer, insulating isothermic channels to measure temperature accurately. This single use item should interface with a control unit that is compatible with the specifications mentioned in the non consumable section. , 2-octyl cyanoacrylate with self adhesive mesh for skin closure , Tubular elastic dressing made of cotton and elastane for tight dressing of scalp. , Expanded poly tetraflouroethylene ePTFE (teflon patch) 0.4 mm for use in microvascular decompression. 1 x 1 cm size , Container for sending pathological biopsy (100 ml capacity) , Triple lumen set for use in the inline warmer which you have to quote below in the non consumable , Carboxymethyl cellullose and polyethylene oxide in injectable prefilled syringe (3 ml) for use in spine surgery for adhesion prevention and for reduced postoperative pain. Suitable randomised controlled human studies showing effectiveness should be available. , Non woven cohesive bandage which is breathable and stretcheable 10 cm breadth x 4 meters. It should stick to itself so that bandaging can be done without typing , clipping or taping. , Scalp (head) decontamination cap impregnated with polyhexamethylene biguanid in gel form. , Medical grade silicone rubber (addition cure type silicone rubber adding 50:50 of part A and B). Either colourless or skin colour. Should cure in 24 hours or faster in oven. 1 Kg. Equivalent of Aditya Silicone material seen at this link https:'/'/www.adityasilicone.com'/product'/aditya-silicone-rubber-rtv-m-10-body-parts-1-kg'/ , Sub-cortical suction stimulator for stimulating subcortical white matter while resecting gliomas to elicit a motor evoked potential response. , Intra-arterial drug infusion catheters Non thrombogenic coated long catheters of 160-170 cms length with 0.015, 0.0165 inches internal diameter to be used as indwelling intra-arterial catheter for drug delivery in internal carotid artery over a prolonged period of time (up to 100 hours). , Conformable balloon catheter with soft balloon with total length 150 cms. Balloon length should be 7 mm and balloon diameter should be 4 mm. Catheter should be compatible for use in the common carotid artery for occlusion. Compatible guide wires should be supplied with each catheter. , Conformable balloon catheter with soft balloon with total length 150 cms. Balloon length should be 7 mm and balloon diameter should be 7 mm. Catheter should be compatible for use in the common carotid artery for occlusion. Compatible guide wires should be supplied with each catheter. , Surgeon gown (medium size) which is a fully wrap around variety and can be tied in front, with water, alcohol resistance. Outer layer spun bound repellant layer with inner two layers with antibacterial property (melt blown), and innermost layer for fabric strength (spun bound) Soft elastic wrist cuff. Adjustable neck line needed. Low linting. Sample absolutely required. Must meet or exceed EN13795 standards or else will not be considered.Quote separately for Tape covered double-stitched seam type gown as well as the one with ultrasound bonded seam , Surgical Gloves : Polyurethane inner coating with textured external surface and dark coloured to prevent reflective glare. Internal surface should have powder free, polymer coated and siliconated,protein less than 30micro gram and preferrable thickness at finge is 0.18mm. Size :6.5, 7 & 7.5 , Surgical Gloves : Water-based polyurethane inner coating, wet hand donning, thinner latex at the palm and fingers with high tear resistance, resistant to alcohol-based hand disinfectants and viral penetration, band at glove cuff should have secure hold on the surgical gown, with low allergenicity. Size : 6.5, 7 & 7.5 , Latex free surgical glove in sizes 6.5, 7 and 7.5 presterile for use in patients who can potentially develop latex allergy as in patients who undergo multiple surgeries for spinal cord dysraphism , Surgical Under Glove: Internal surface - Polyurethane coated & moisturized hydrasoft coated, preferable finger thickness 0.19mm, teal green coloured and gamma sterilized. Size: 7.0 & 7.5 , HEPA and Carbon filter for regular air purifier in the non consumable section (lowest quote will be based on the combined value of machine and filter) , HEPA and Carbon filter for high-end air purifier in the non consumable section (lowest quote will be based on the combined value of machine and filter) , Urinary drainage bag (Urometer) for collection of urine from Foley catheter with volume measurement compartment separate from bag lines for as little as 50 ml so that hourly urine output can be monitored, non-return valve and transparent. , Self contained double lumen suction catheter which may be used for endotracheal suctioning on ventilated patients with plastic envelope containing threadable and retractable soft blunt nosed catheter. A thumb depressable switch to initiate and stop suctioning when connected to wall suction. Rotating access valve to isolate the airway during closed position. Simultaneous irrigation and suctioning should be possible (mandatory requirement). Must have a port to attach an MDI adaptor along with an MDI adaptor Labels for days of use or to indicate when to replace. For multiple use over a period of 3 days or more. Demo absolutely mandatory before selection and if there is any leak or suboptimal performance on testing it will be rejected. (Size: 12 French : 25cms & 45cms, 14 French : : 25cms & 45cms) , Cranioplasty material using heat mouldable high density porous polyethylene material with pore size of 100 microns or less for tissue integration. Size 12 x 17 cm of 6 mm thickness. , Customized craniomaxillary repair system using PEEK material which can be implanted. The material should be fabricated according the CT scan reconstruction data of a particular patient. , Customized craniomaxillary repair system using titaniium material which can be implanted. The material should be fabricated according the CT scan reconstruction data of a particular patient. , Customized 3 D printed rigid model based on CT or MRI data of particular patient for planning operative approach. Should include soft tissue structures and fine structures like vessels, and internal architecture of temporal bone. Price should be mentioned per ml (cm3) of final product. , Customized 3 D printed rigid and flexible model based on CT or MRI data of particular patient for planning operative approach. Should be include soft tissue structures and fine structures like vessels, and internal architecture of temporal bone. Price should be mentioned per ml (cm3) of final product. , Medical grade Polylactic acid filaments (PLA) 1.75 mm diameter for 3 dimensional printing using a 3 D printer such as Wanhao Duplicator i3 V2 , Operation trolley drape made of fluid (water and alcohol) impermeable drape of size 1.5 x 1.5 m size (EN13795 standard) , Silicone tracheostomy tube, cuffless with obturator, speaking hole, sizes of 4, 6 and 8 , Silicone tracheostomy tube, cuffled with obturator, speaking hole, size of 4, 6 and 8 , Incentive spirometer which shows exact volumes per minute. Should have a marker which indicates the desirable rate of inspiration. It should ensure that patient inhales rather than exhales. Should have a port for connecting oxygen while in use. Should have a bed rail holding loop built into the device. Flow setting 500 ml to 4000 ml'/sec , Incentive spirometer which shows exact volumes per minute. Should have a marker which indicates the desirable rate of inspiration. It should ensure that patient inhales rather than exhales. Should have a port for connecting oxygen while in use. Should have a bed rail holding loop built into the device.; Low flow setting 100 ml to 600 ml'/sec, suitable for pediatric patients or patients with poor reserve. , Distilled water in cans'/ appropriate containers with dispensing knob , Face mask with shield : Surgeon face mask with clear plastic visor shield built in, with malleable nose clip, latex free. Should prevent aerosol or droplet splash on eyes. (transparent distortion free optical characteristics, crease free nature of visor is absolutely important) , 3d contoured full face optically clear face protection mask with foam insert at forhead and convection venting ports which allow hot air to ascend. The shield should fit on top of an N95 mask , Endotracheal tube with an antibacterial coating which acts by virtue of galvanic effect of a thin coating of gold, palladium and silver. It should have a low pressure low volume cuff and a subglottic aspiration catheter port which should be above the cuff. Quote for a single size. We will place the sizes and quantity of each size according to need. (sizes 6.0 to 8.5) , Non-glutaradehyde based floor cleaning agent for the Intensive care unit using a quarternary ammonium compound and non intonic surfactants. Surfactants should be biodegradable according to EU detergent guideline. A 0.5% solution should have EN 1276 bactericidal activity even with high soiling. Quote for one liter of pure solution which will give a 0.5% solution with EN1276 activity. , Non glutaraldehyde based enzymatic cleaner with disinfiectant cleaning solution. Quote for 500ml pack , Non ionic amphoteric surfactant based cleaning agent for insturments and neuroendoscopes. It should be compaticle for use in ultrasonic baths. 1% solution in 500 ml bottles , Disinfectant wipes for surface cleaning to be used in Neurosurgery OT & ICU. Disinfectant should contain ethanol, 2- propranalol and 1 propranalol with 90 pull outs (12 X12 inches) which are lint free . Should be aldehyde free. , Disinfectant wipes for surface cleaning ato be used in Neurosurgery OT & ICU nd for cleaning ultrasound probes. Disinfectant should contain didecyldimethyl ammoniium choride and quarternary ammonium compounds which are active against MRSA , yeasts and Papova '/polyoma viruses. 80 or more pull outs 29x22 cm size approximately , Water less, brush less surgical hand antiseptic containing Chlorhexidine gluconate (1%) and Ethylalcohol (61 % w'/w). The product must be FDA-NDA approved for use as water less surgical scrub. 500 ml bottles. , "Antimicrobial Hand rub in 500 ml bottles Should contain 80% volume'/volume (v'/v) ethyl alcohol or 70% v'/v isopropyl alcohol. Other antimicrobial agents such as chlorhexidine need not be added. Hydrogen peroxide may be used as described in WHO guide. It must contain emollients and moisturizers (humectants such as glycerol). No added fragrances or colours should be added. The dispenser should have a mechanism to squirt out 3 ml of the product on the hand when the user presses on the dispensing mechanism once. The dispenser bottle should have 500 ml volume. A bottle holder should be provided with every five bottles or the price of the bottle holder can be quoted separately." , "Antimicrobial Hand rub in 500 ml bottles with a foaming agent and'/or foaming mechanism in dispenser to avoid splashing on patient records and linen Should contain 80% volume'/volume (v'/v) ethyl alcohol or 70% v'/v isopropyl alcohol. Other antimicrobial agents such as chlorhexidine need not be added. Hydrogen peroxide may be used as described in WHO guide. It must contain emollients and moisturizers (humectants such as glycerol). No added fragrances or colours should be added. The dispenser should have a mechanism to squirt out 3 ml of the product on the hand when the user presses on the dispensing mechanism once. The dispenser bottle should have 500 ml volume. A bottle holder should be provided with every five bottles or the price of the bottle holder can be quoted separately." , Alcohol free barrier film that can be sprayed on the skin which acts by forming an impermeable polymer film. It should remain on skin for 72 hours. In 28 ml spray bottle . , "1)Non Rechargeable implantable neuro stimulator(MRI compatible ) : 1)Dual-channel implantable neurostimulator for use with deep brain stimulation (DBS) leads, and patient programmer. Advanced programming features for patients and clinicians. a)MRI Campatible *, b)Number of defined groups 1 to 4 c)Number of programs per group 1 to 4 d)Electrode configurationb 1 to 4 electrodes per lead as anode, cathode, or OFF e)Case defined as anode or OFF f)Amplitude (voltage mode) 0 to 10.5 V with 0.05 V or 0.1-V resolution g)Amplitude (current mode) 0 to 25.5 mA with 0.1-mA resolution h)Amplitude – upper patient limit By hemisphere: i)Tracking limit: +0 to +2 (0.2 resolution); +2 to +4.5 (0.5resolution) j)Amplitude – lower patient limit By hemisphere: k)Tracking limit: -0 to -2 (0.2 resolution); -2 to -4.0 (0.5resolution); full rangec l)Pulse width 60 to 450 μs (10 μs resolution) m)Pulse width – upper patient limit Tracking limit: +0 to +100 μs (10-μs resolution) n)Pulse width – lower patient limit Tracking limit: -0 to -100 μs (10-μs resolution) o)Rate (voltage mode) 2 to 250 Hz (resolution: 1 Hz from 2 Hz to 10 Hz, 5 Hzfrom 10 Hz to 250 Hz)d p)Rate (current mode) 30 to 250 Hz (5-Hz resolution)dRate – upper patient limit Tracking limit: +0 to +50 Hz (10-Hz resolution)Rate – lower patient limit Tracking limit: -0 to -50 Hz (10-Hz resolution) q)SoftStart'/Stop OFF, ON: 1, 2, 4, or 8 second ramp duration r)Cycling OFF, ON: 0.1 s to 24 hr (resolution: 0.1 s from 0.1 s to1 s, 1 s from 1 s to 59 s, 1 min from 1 min to 59 min, 1 hrfrom 1 hr to 24 hr), NON RECHARGEABLE" , "2)Rechargeable implantable neuro stimulator (MRI compatible ) : Dual-channel rechargeable implantable neurostimulator for use with deep brain stimulation (DBS) leads, and DBS patient programmer and patient recharger system. Advanced programming features for patients and clinicians. a)MRI Campatible , b)Number of defined groups 1 to 4b No more than 16 programs may be defined within the 4 groups. c)Number of programs per group 1 to 4b d)Electrode configuration Up to 4 electrodes as anode, cathode, or OFF e)Case defined as anode or OFF f)Amplitude (voltage mode) 0 to 10.5 V with 0.05 V or 0.1-V resolution g)Amplitude (current mode) 0 to 25.5 mA with 0.1-mA resolution h)Amplitude – upper patient limit By hemisphere: i)Tracking limit: +0 to +2 (0.2 resolution); +2 to +4.5 (0.5resolution) j)Amplitude – lower patient limit By hemisphere: k)Tracking limit: -0 to -2 (0.2 resolution); -2 to -4.0 (0.5resolution); full rangec l)c Full range = -10.5 V (voltage mode); -25.5 mA (current mode) m)Pulse width 60 to 450 μs (10-μs resolution) n)Pulse width – upper patient limit Tracking limit: +0 to +100 μs (10-μs resolution) o)Pulse width – lower patient limit Tracking limit: -0 to -100 μs (10-μs resolution) p)Rate (voltage mode) 2 to 250 Hz (resolution: 1 Hz from 2 Hz to 10 Hz, 5 Hzfrom 10 Hz to 250 Hz)d q)d Rate limited to 125 Hz when two programs are active on a single lead. r)Rate (current mode) 30 to 250 Hz (5-Hz resolution)d s)Rate – upper patient limit Tracking limit: +0 to +50 Hz (10-Hz resolution) t)Rate – lower patient limit Tracking limit: -0 to -50 Hz (10-Hz resolution) u)SoftStart'/Stop OFF, ON: 1-, 2-, 4-, or 8-second ramp duration v)Cycling OFF, ON: 0.1 s to 24 hr (resolution: 0.1 s from 0.1 s to1 s, 1 s from 1 s to 59 s, 1 min from 1 min to 59 min, 1 hrfrom 1 hr to 24 hr), RECHARGEABLE" , "3)Patient Programmer A)Allows patients with neurostimulators to check therapy and neurostimulator battery status, and adjust settings or change programming group according to clinician-determined parameters. 1. Patient programmer technical specifications: a)Power source 2 AAA alkaline batteries (non-rechargeable, LR03) b)Operating temperature +9 °C to +43 °C (+49 °F to+110 °F) c)Temperature limitation -34 °C to +57 °C (-30 °F to+135 °F) d)Size Approximately 9.4 cm x 5.6cm x 2.8 cm (3.7 in x 2.2 inx 1.1 in)Weight, including e)batteries Approximately 111 g (3.9oz.) f)Battery life 2 months (average) for alkaline batteries g)Mode of operation Continuous" , "4)Deep Brain stimulation leads : Quadripolar leads for delivery of electrical impulses to the target region of the brain.One 4-electrode lead, for use with extension with in-line connector. Lead electrodes 1.5 mm, spaces 0.5 mm. should be Available in 28-cm length and 40-cm length. a) Linear connector b) Lead resistance: <100 ohms c) Available in 28 cm and 40 cm d) Diameter: 1.27 mm e) Distance from tip of lead to first electrode: 1.5 mm f) Shape: Cylindrical g) Length of surface electrode: 1.5 mm h) Spacing between electrodes 1.5 mm i) Spacing between electrodes 0.5 mm" , "5)stretcheable coil DBS (Deep Brain Stimulation) extension DBS Stretch-CoilTM lead extension and accessories to connect neurostimulator to DBS lead. a) The extension has four connectors on the distal end and eight connectors on the proximal end. The in-line distal end connects to a lead. The proximal end connects to a neurostimulator. (should be compatible to earlier mentioned DBS parts) b) Low profile connector" , Lock to prevent migration of deep brain stimulation leads when the stylet is taken off (stimulator lock) , "Programmable Intrathecal drug delivery pump : 1)Implantable intrathecal system with flexible dosing programmable pumps allowing independent dosing intervals with a fixed Basal Rate that will be delivered between specified times. pump and catheter information should be stored in pump memory. a)Radiopaque identifier •20 mL—NGP b)Pump Case Thickness •20 mL—19.5 mm, Weight (empty) •20 mL—165 g Displacement volume •20 mL—91 mL, Diameter 87.5 mm(Largest diameter Material Titanium and silicone, Suture loops Yes Mesh pouch Optional c)Pump Reservoir Volume •20 mL d)Reservoir Fill Port Septum puncture life 500 punctures e)Catheter Access Port Septum puncture life 500 punctures Flow Rate Programmable rate1 24 mL'/day max •40 mL—NGV •40 mL—26.0 mm •40 mL—175 g •40 mL—121 mL including CAP) •40 mL 0.048 mL'/day min Leakage rate (stopped pump) 0.030 mL'/day max Bacterial Retentive Filter, Pore size 0.22 μm (micron) Power Source; Battery Lithium hybrid cathode Longevity Rate dependent; Must provide supply of compatible baclofen drug to last atleast 1 year for each implant as and when we implant in a patient" , Implantable phrenic nerve stimulator system (quote price for battery if it comes with the system) , Implantable programmable, rechargeable battery compatible with the phrenic nerve stimulator , Implantable programmable, non-rechargeable battery compatible with the phrenic nerve stimulator , Implantable phernic nerve stimulator with radiofrequency receiver (without implantable battery) , Implantable diaphragm pacing system (FDA approved) , Vagal nerve stimulator for intractable epilepsy. All material for implantation and required training or certification, if any should be provided for 2 surgeons. , CUSA (Ultrasonic Dissector) Tips : Quote for cusa tips of various sizes. It should be compatible with existing CUSA (25 Khz Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) available in Neurosurgery OT. If not compatible with this machine, you must provide the machine on loan basis. Quote a uniform rate for a tip if possible. We will inform the size of the tip at the time of placing order. , CUSA (Ultrasonic Dissector) Tips : Quote for cusa tips of various sizes. It should be compatible with existing CUSA (34 Khz Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) available in Neurosurgery OT. If not compatible with this machine, you must provide the machine on loan basis.Quote a uniform rate for a tip if possible. We will inform the size of the tip at the time of placing order. , CUSA (Ultrasonic Dissector) bone removing Tips : Quote for cusa tips of various sizes. It should be compatible with existing CUSA (Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) available in Neurosurgery OT. If not compatible with this machine, you must provide the machine on loan basisQuote a uniform rate for a tip if possible. We will inform the size of the tip at the time of placing order. , Ultrasonic Dissector tubings : Quote for disposable cusa tubing of various sizes. It should be compatible with existing CUSA (Ultrasonic Bone Removal Device, Model: Sonopet, Make : Stryker) available in Neurosurgery OT. If not compatible with this machine, you must provide the machine on loan basis Quote a uniform rate for a the tubings for one set. , Drill Bits : Quote for round fluted burs of various sizes, round diamond burs of various sizes. Should be caompatible with long and short hand pieces of Stryker Neuro Drill available in Neurosurgery OT. If not compatible with this machine, you must provide the machine on loan basis. Quote a uniform rate for a single drill bit. We will inform the size of the tip at the time of placing order. , Drill Bits : Quote for round fluted burs of various sizes, round diamond burs of various sizes. Should be caompatible with long and short hand pieces of Karl Storz Endoscopic Drill available in Neurosurgery OT. Quote a uniform rate for a single drill bit. If not compatible with this machine, you must provide the machine on loan basis We will inform the size of the tip at the time of placing order. , Toner (original manufacturer's ) for canon laser printer (Canon imageCLASS MF-4820D Monochrome Multifunction Laser ) which is compatible with the laser printers in Dept of Neurosurgery. (please confirm with dept before quoting) , Toner (original manufacturer's ) for Lexmark laser printer (Lexmark Multifunction Laser ) which is compatible with the laser printers in Dept of Neurosurgery. (please confirm with dept before quoting) , Toner (original manufacturer's ) for Brother laser printer ( MODEL HL - 22 ) which is compatible with the laser printers in Dept of Neurosurgery. (please confirm with dept before quoting) , "Toner for the Multifunction WIFI all in one colour laser printer that you have quoted in the non-consumable section " , Titanium clip that fixes onto the diploe of the bone flap using a driver. The clip should be able to take a 1.5 mm self tapping screw to attach to the rest of the skull to allow rigid fixation using three such clips. , Microdoppler probe (single use, disposable) 8 MHz 2 mm tip for intraoperative, endonasal use compatible with Mizhuo machine available in our theater. , Microdoppler probe (single use, disposable) 20 MHz 2 mm tip for intraoperative use compatible with Mizhuo machine available in our theater. , "Uniportal endoscopic carpal tunnel release set (disposable single use). Should have blades (Standard and Slimline) assembly. Disposable Blade assembly should feature a retractable blade that rises straight up without curving outward. Blade assembly should click- lock on to the front of the pistol-grip hand piece”. Should have blade (standard and slim) assembly, three sizes hamate finders, synovial elevators. Must provide endoscope on loan basis on a 48 hour notice period before scheduled day of surgery if endoscope is not available'/functioning at JIPMER" , Body decontamination wipes impregnated with polyhexanide. One pack should have 10 wipes. , Reflective sphere suitable for Neuronavigation (stealth S7, Medtronic, "glions") , Flexometallic electromyography (EMG) endotracheal tube for intraoperative nerve monitoring (7 MM & 7.5 MM) , Non Consumables ( Items costing upto Rs.1,00,000/- only) , Twist Hand Drill : hand held twist drill set with chuck, drill bits of various sizes [10 Nos.] , Brain cannula [ventriculostomy cannula] : opening in the tip, with obturator [stylet] , Leyla retractor arms : Flexible arms compatible with any of the current Leyla base unit in Jipmer operation theatre. , Micro Suction regulator : Should be attached with suction tube and to be controlled by the Surgeon , Silicone pediatric head holder : Pediatric silic
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
Refer Documents -
Document Cost
590.00 -
Estimated Cost
10000000.00
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane