BOQ Items
# Item Quantity Units
1 SCHEDULE "A" Part - I (Building works) Details of prepriced schedule is given in tender documents. 1.00 Lump sum
2 SCHEDULE "A" PART-II ( Site Clearance, Area Development, Excavation & Earth work ) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
3 SCHEDULE "A" PART-III (Internal Electrification other than PEB hangar ) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
4 SCHEDULE "A" PART-IV (Internal Water Supply other than PEB hangar ) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
5 SCHEDULE "A" PART-V (Roads, Path & Culverts ) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
6 SCHEDULE "A" PART-VI (Fire Fighting) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
7 SCHEDULE "A" PART-VII (External Electrification) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
8 SCHEDULE "A" PART-VIII (External water supply) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
9 SCHEDULE "A" PART-IX (Lightening Protection) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
10 SCHEDULE "A" PART-X (DG Sets) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
11 SCHEDULE "A" PART-XI (Aviation obstruction Light/ Conduit for TV & Telephone) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
12 SCHEDULE "A" PART-XII(Refrigeration and Air Conditioning) Details of prepriced Schedule is given in tender documents. 1.00 Lump sum
13 SCHEDULE "A" PART-XIII (Provisional sum) This item covers the cost of (i) Demolition of existing floor ( At location of H-2 hangar and its Annexe), demolition of existing foundation at the location of H-2 Hangar and its Annexe (If required). (ii) Designining the foundation, getting it vetted from IIT/NIT/Govt Engg College and Material and lobour including execution of complete foundation of Hangar -2 and its Annexe. (iii) Design of foundation and its vetting from IIT/NIT/Govt Engg College is deemed to be included in the over all cost of provisional lumpsum, nothing extra shall be paid. (iv) While designing the new foundation, existing foundation can be made use of in hybrid mode with new foundation, post adequate testing of its strength and approval from Accepting Officer. Decision of feasibility of utilizing existing foundation in hybrid mode with new foundation will rest solely with Accepting Officer. (v) Items which are not available on SSR shall be priced as per Condition 62 of IAFW 2249. 1.00 Provisional Lump sum
14 SCHEDULE "A" PART -XIV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
15 (a) Design, manufacture and erection of PEB Hangar in steel structure for construction of Hangar No-1 of size as shown in drawing, with PCC block masonry wall upto 3.0mt height on both side of hangar, horizontally sliding type steel automated door as shown in drawing on front side, galvalume sheet in roofing and cladding, all primary steel surfaces painted with epoxy based paint, 200mm thick PQC of flexural strength of 45mpa in floor Including 200mm thick GSB - V of grading,150mm thick (Compacted thickness) WMM in two layers 75mm each, 125mm thick (Compacted thickness) DLC, 10mm thick sand filling, HDPE sheet 400micron, non circular synthetic fibre, Expansion joints, Construction Joints, Dummy joints, 5.3mm ESD- Epoxy antiskid floor coating, including excavation in any type of soil/soft disintegrated rock and foundation all as specified in Schedule A notes, Particular specification, drawings and Tender documents. (b) Design & construction of Annex Bldgs for Hangar No 1 (G+3 configuration) in permanent specifications, RCC framed structure including foundation, RCC water storage tank (20000 Ltr Capacity on roof slab of Annexe Building for fire fighting) all as specified in Schedule A notes, Particular specification & drawings (Note: Internal Electrification and Internal water supply for Annexe of Hangar No 1 building shall be measured and paid under relevant item of Sch 'A' Part-III & Part-IV) 1.00 Each Job
16 (c) Design, supply and installation of complete internal electrification scheme including artificial lighting to Hangar No -1 as per IS 732 2019 / IEC 60335 /NBC 2016. Internal artificial ligthing of hangar shall be with energy efficient suitable LED fittings in compliance of ICAO norms to ensure uniform distribution of light with minimum lux level 300- 500 -750 as per NBC-2016 or as mandated by GRIHA 2019 and minimum glare level index should be less than 2 to enhance visual comfort . LED light fittings has to be suitably fitted on walls/ceiling considering safety of aircraft and ease of maintenance. Selection of LED light fittings shall be as per NEC / relavent IS / ECBC norms. Internal electrification scheme including artificial lighting shall be vetted by NIT/IIT and got approved by accepting officer before commencement of work. (d) The following electric points and fixtures shall be provided inside the hangar: 1. 3 Phase industrial socket 32 A - 10 Nos 2. 1 Phase industrial socket 20 A - 10 Nos 3. Power Point 16A/5A - 20 Nos 4. Air Circulators 450mm Sweep 24 Nos. 5. Supply and fix of industrial plug and socket 10 Nos of 63 Amps with 4P MCB, 3 Phase +neutral and earth connection ,IP 67 protection, with necessary internal wiring and other accesories for charging purpose. (e) S& F wind driven turbo ventilators fixed each per 100 sqm (min diagonal 14.5 mtrs) of roof plan area of hanger.The turbo ventilators shall be of average capacity of 1500 to 2000 CFM with neck diameter 600-750 mm and 42 nos fins. Top plate and bottom rings shall be made of high grade stainless steel (SS-304) and fins of high grade aluminium H-140 of minimum thickness 0.71mm. The base of hopper shall be constructed with UV stabilsed FRP of minimum thickness 3 mm matching with roof sheet profile The rate shall be deemed to include fixing of FRP base alongwith ventilator and providing special leak proof tape from all sides making it totaly water tight etc. complete all as specified and driected. NOTE: (I) All item mentioned at Sl. No 15.00 & 15.01 are part of lumpsum, irrespective of availibility of such items in any other part of Schedule 'A' (Provisional) (II) Lumpsum cost of Sl. No 15.00 & 15.01 shall be entered against Item No 15.00
17 (a) Design, manufacture and erection of PEB Hangar in steel structure for construction of Hangar No-2 of size as shown in drawing, with PCC block masonry wall upto 3.0 mt height on both side of hangar, horizontally sliding type steel automated door as shown in drawing on front side, galvalume sheet in roofing and cladding, all primary steel surfaces painted with epoxy based paint, 200mm thick PQC of flexural strength of 45MPa in floor Including 200mm thick GSB - V of grading,150mm thick (Compacted thickness) WMM in two layers 75mm each, 125mm thick (Compacted thickness) DLC, 10mm thick sand filling, HDPE sheet 400micron, non circular synthetic fibre, Expansion joints, Construction Joints, Dummy joints, 5.3mm ESD- Epoxy antiskid floor coating all as specified in Schedule A notes, Particular specification, drawings and Tender documents. (b) Design & construction of Annex for Hangar No 2 (G+3 configuration) in permanent specifications, RCC framed structure, RCC water storage tank (20000 Ltr Capacity on roof slab of Annexe Building for fire fighting) all as specified in Schedule A notes, Particular specification & drawings (Note: (i) Internal Electrification and Internal water supply for Annexe of Hangar No 2 building shall be measured and paid under relevant item of Sch 'A' Part-III & Part-IV) (ii) The quoted amount for this item shall not include cost of foundation design including M&L and execution of foundation. The same shall be as per rate quoted against item No 13 ie, Sch 'A' Part XIII for provisional lumpsum. (iii) The quoted amount for this item includes cost of all items and structures of Hangar -2 and its annexe, above the top of pile cap/grade beam in case of pile foundations and top of plinth beam in case of raft/open foundation. Dowels of columns to be anchored in pile cap shall also be part of lump sum. 1.00 Each Job
18 (c) Design, supply and installation of complete internal electrification scheme including artificial lighting to Hangar No 2 as per IS 732 2019 / IEC 60335 /NBC 2016. Internal artificial ligthing of hangar shall be with energy efficient suitable LED fittings in compliance of ICAO norms to ensure uniform distribution of light with minimum lux level 300- 500 -750 as per NBC-2016 or as mandated by GRIHA 2019 and minimum glare level index should be less than 2 to enhance visual comfort . LED light fittings has to be suitably fitted on walls/ceiling considering safety of aircraft and ease of maintenance. Selection of LED light fittings shall be as per NEC / relavent IS / ECBC norms. Internal electrification scheme including artificial lighting shall be vetted by NIT/IIT and got approved by accepting officer before commencement of work. (d) The following electric points and fixtures shall be provided inside the hangar: 1. 3 Phase industrial socket 32 A - 10 Nos 2. 1 Phase industrial socket 20 A - 10 Nos 3. Power Point 16A/5A - 20 Nos 4. Air Circulators 450mm Sweep 24 Nos. 5. Supply and fix of industrial plug and socket 10 Nos of 63 Amps with 4P MCB, 3 Phase +neutral and earth connection ,IP 67 protection, with necessary internal wiring and other accesories for charging purpose. (e) S& F wind driven turbo ventilators fixed each per 100 sqm (min diagonal 14.5 mtrs) of roof plan area of hanger.The turbo ventilators shall be of average capacity of 1500 to 2000 CFM with neck diameter 600-750 mm and 42 nos fins. Top plate and bottom rings shall be made of high grade stainless steel (SS-304) and fins of high grade aluminium H-140 of minimum thickness 0.71mm. The base of hopper shall be constructed with UV stabilsed FRP of minimum thickness 3 mm matching with roof sheet profile The rate shall be deemed to include fixing of FRP base alongwith ventilator and providing special leak proof tape from all sides making it totaly water tight etc. complete all as specified and driected. NOTE: (I) All item mentioned at Sl. No 16.00 & 16.01 are part of lumpsum, irrespective of availibility of such items in any other part of Schedule 'A' (Provisional) (II) Lumpsum cost of Sl. No 16.00 & 16.01 shall be entered against Item No 16.00
19 Design and Construction of POL Storage Accommodation including foundation, RCC framed structure etc all as specified in Schedule A notes, Particular specification & drawings. Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively 1.00 Each Job
20 Design and Construction of Battery Charging shop including foundation RCC framed structure etc all as specified in Schedule A notes, Particular specification & drawings. Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively 1.00 Each Job
21 Design and Construction of Under ground sump of 150000 ltrs capacity including foundation RCC structure etc all as specified in Schedule A notes, Particular specification & drawings. Note: (i) Underground sump shall be designed cosidering load of pump house (ie, Item No 01 of Sch 'A" Part-I) which is to be costructed over the sump all as shown in drawing No CE(CG)GOA/AR-PH-1036/2022 sheet 1R1/1. (ii) Inter connecting of UG sump and pump house (to be constructed under Item No 01 Sch 'A' Part-I) also to be designed and quoted rate is deemd to be included in the rate quoted against this item. 1.00 Each Job
22 S&F HDPE bird proofing net 1mm thick, aperture size 25mmx25mm supported on aluminium section frame work, (Aluminium work to be measured separately) 2200.00 Sqm
23 S&F supporting anodised aluminium frame work shall be of panel size 4.0m x 2.0m with main aluminium Tee size 101mm x 45mm x 3.1mm thick & cross aluminium Tee size 40mm x 40mm x 5mm thick complete all as specified and directed or as specified by GE. 6500.00 Kgs
24 FIRE FIGHTING: Supply and fix Foot Valve conforming to IS 4038, 100 mm dia. 1.00 EACH
25 Supply and fix Foot Valve conforming to IS 4038, 150 mm dia. 2.00 EACH
26 Supply and fix Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports complete 10.00 RM
27 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia. 1.00 EACH
28 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1100 Volts grade.
29 3 Core, 1.5 Sq mm, 300.00 RM
30 6 Core, 1.5 Sq mm, 300.00 RM
31 Supply install LT motor control panel floor mounting type fabricated from 2.00 mm thick CRCA sheet, dust and vermin proof complete with aluminium bus bar 100 Amp and with following accessories:- (a) MCCB TPN 63 Amps 25 KA as incomming -01 (b) MCB TPN 40 Amps 16 KA -01 (c) MCB SPN 16 Amps 16 KA -01 (d) Combo Digital Volt meter & Ammeter 0-500 Volts and selector switch-01 No, CT ratio 100/5A (e) Star delta starter of capacity 10 HP -01 No (f) Led Phase indicating lamps R Y B-01 Set 2.00 EACH
32 S& F wall mounted LED emergency Exit signage luminaireLight up using regular mains supply comes with a unique rechargeable NI-Cd battery capable of emergency back up upto 02 hours ( cat No BESL 03 LED WBB Make - Bajaj or equivalent to Havells/ Philips 16.00 EACH
33 S & F Monitors SS-304 geared swivel nominal water way of size 63 mm flow capacity 1750 lpm/ min at 7 Kg / Sqcm inlet pressure stailnelss steel type (SS304) with geared swivel joints with handwheels have suitable inlet flange and nozzle of specified type and capacity. Monitor shall good hydraulic performance and range. 4.00 EACH
34 Supply and fixing S.S Foam Tank Made out of 3mm thick SS 304 plate with required nozzles, stand, level gauge, coupling, jointing materials, etc, with all required accessories of capacity 200 Ltrs and all as specified and directed. 2.00 EACH
35 S & F foam generator of capacity of 7 Kg/Sqcm total water flow 230 LPM complete all as specified and as directed 2.00 EACH
36 AFFF 3% Foam Concentrate, as per IS:4989, Part-II and all as specified and directed. 400.00 Litre
37 Supply, install,test and commisioning ABC dry powder ceiling mounted atomatic fire suppression system of capacity 5 Kg all as specified and as directed. 6.00 EACH
38 Supply and installation at approved location approved make fire sand bucket of 24 gauge galvanised steel sheet ,each set shall have 4 buckets with stand & Showel etc, complete. 4.00 EACH SET
39 Supply, Installation,Testing & commissioning of MECHANICAL FOAM type fire extinguisher of 9 Ltrs confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 18.00 EACH
40 Supply, Installation,Testing & commissioning of DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 18.00 EACH
41 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 18.00 EACH
42 EXTERNAL ELECTRIFICATION: Supply, Installing, commissioning and testing 11KV outdoor type Compact Sub Station consisting of 01 No transformer 500 KVA, 11/0.433 KV CRT dry type energy effiency level-II confirming to IS 1180 (part-1) of 2014 with latest amendments, 01No, SF-6 Vaccum circuit Breaker 11KV, 630A, fault level not less than 18kA, draw out type as transformer feeder. VCB shall have series self-powered microprocessor based numerical O/C & E/F relay, Aluminium bus bars, digital voltmeters, ammeter with suitable CT/ PT mechanical indications for breaker ON/ OFF/ TRIP/ SPRING CHARGED etc. and LT PANEL (main) fabrications using 2mm thick CRCA sheet steel, comprising of 01no 433V LT ACB 800 amps 4 Pole draw out type, digital voltmeter, ammeter with suitable CT with aluminium bus bars of current rating 1000 Amps from LT side of transformer to ACB. OUTDOOR ENCLOSURE: Outdoor type enclosure made of minimum 2.0mm thick GI/ CRCA MS sheet. The enclosure shall have IP 54 degree of protection for HT & LT switch gear for transformer compartment. The enclosure exterior shall be polyurethene metallic painted. Each compartment will be provided with the door and pad locking arrangement. The compartment illumination lamp with door operated switch shall be provided for each compartment, interconnection between HT switchgear & transformer using XLPE single core cable & interconnection between transformer & LT switchgear using busbars internal earthing connection. All metallic components shall be earthed to a common eathing point. NOTE: (i) The CSS shall be fully factory assembled. NO ASSEMBLY AT SITE SHALL BE PERMITTED. (ii) Foundation shall be as per recommendation of OEM and deemed to be included in the above quoted rate. 1.00 EACH
43 Supply install, and commissioning LT feeder pillar Outdoor, type made out of 3.15mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounted plate, frame and canopy, confims to IEC61439-2 with following assesccories suitable for incoming/outgoing arrangements:- a) Incoming- ACB 630A 4 pole, 65/70KA, mechanical draw out type-01 No. b) Out goings :- i) MCCB 250A ,4 pole, 50 KA-03 Nos ii) MCCB 120A ,4 pole, 35 KA-02 Nos iii) MCCB 32,4 pole, 35 KA-03 Nos iv) Digital panel meter for Volt/Amp/KWH & PF, necessary CT-01 No 1.00 EACH
44 Supply install, and commissioning LT feeder pillar Outdoor, type made out of 3.15mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounted plate, frame and canopy, confims to IEC61439-2 with following assesccories suitable for incoming/outgoing arrangements:- Incoming:- a) ACB 800A 4 pole, 50 KA-01 Nos Out going ;- b) ACB 800A 4 pole, 65/70KA, mechanical draw out type -01 No. c) MCCB 160A 4 pole, 50 KA-01 Nos d) MCCB 200A 4 pole, 50 KA-03 Nos e) LED indicating lamp set-01 Set of three (f) Digital panel meter for volt Amp/Volt/KWH & PF, necessary CT-01 No 2.00 EACH
45 Supply and fix LED flood light 120 watt 230 V AC IP 65 protection out door type with thermal manangement in multiple optics and equipped with IP 66 protection,with impact and corrosion resistant complete with driver and lamp including fixing arrangement complete all as directed. 20.00 EACH
46 Supply and fixing cable tray 200mm wide X 25mm deep hot dip galvanized with standard slot pattern manufactured from CRCA sheet 2.00mm thick, perforated type including provision of fixing arrangement, nuts & bolt etc for proper securing to walls/beams for suspended from ceiling, complete all as specified and directed. 60.00 RM
47 Supply and fixing cable tray 150mm wide x 50mm deep hot dip galvanized with standard slot pattern manufactured from CRCA sheet 2.00mm perforated type including provision of fixing arrangement, nuts & bolts etc for proper securing to walls beams or suspended from ceiling, complete all as specified and directed 50.00 RM
48 Supply and fix FRP looping box of size 250x200x105mm with connector and comprising of MCB SP 10 Amps, ISI marked, 240V complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/Steel Pole/ wall etc complete all as specified and directed. 10.00 EACH
49 EXTERNAL WATER SUPPLY:- Supply and fix foot valve confirming to IS 4038,50 mm dia 2.00 EACH
50 Supply and install Monoblock pump set suitable for 415 v, 3 phase system having capacity 7.5 HP including GI pipe of suitable size for inlet and outlet connection including necessary PCC platform/ foundation for pump complete all as directed 2.00 EACH
51 Supply and fix DOL starter suitable for and up to 7.5 HP in & including sheetmetal enclosure and fixing arrangement complete all as directed. 2.00 EACH
52 Construction of valve chamber with inner dimension 600x600x900 mm suitable for 80 mm sluice valves with PCC (1:4:8) 150 mm thick type D2 for foundation, Brick masonary 230 mm wall in CM (1:4), PCC (1:2:4) 75 mm type B-1 for coping, rendering in CM (1:4) 15 mm thick including provision of 3 mm thick MS sheet cover and 25 x25x 3 mm angle frame embeded in coping with two coats of synthetic enamel paint over a coat of red oxide primer with locking arrangements including necessary earth work complete all as specified and directed by Engr-in-charge. 1.00 EACH
53 DG SET: Supply, installation, testing and commissioning of silent Diesel Engine driven generating set 415 Volts, three phase 4 wire, engine as per IS: 10001/ 10002 and alternator as per IS: 4722/ IS:13364 complete with anti vibration mounting etc, AMF control panel with necessary meters and sound proof canopy of capacity of 400 KVA comprising of the following :-. (A) DIESEL ENGINE: Liquid cooled, for 400 KVA developing suitable BHP @ 1500 RPM.,rail mounted, engine driven radiator of adequate capacity, with blower fan, fan guard, fan belts etc. The diesel engine shall be vertical to run continuously at 1500 RPM confirming to IS 10001/10002, ISO-3046, BS-5514, standards with an overload capacity of 10% for one hour in every 12 hours of operation. Diesel engine will comply with latest CPCB norms (B) ALTERNATOR : Alternator suitable to deliver output at 1500 RPM, 415V, 0.8 PF (LAG), 50HZ, 3PH, in SPDP enclosure, self-excited & regulated, brushes. The alternator conforms to IS-4722/BS EN 60034/1 IS: 13364 and will be suitable for tropical condition. Full load efficiency of the alternator offered should be above 90% class of insulation shall be H and temperature rise also limited to class H. Enclosure shall confirm to IP-23 and noise level should not be more than 75 dB at 1.0meter distance as per guidelines of Central Pollution Control Board. (C) STANDARD CONTROL PANEL : Following indication/ display and control shall be available in the DG set controller and monitoring system 1.00 EACH JOB
54 (i) 01 No main on/off switch MCB (ii) 01 No set of indicating lamps (iii) 01 No set of instrument fuses. (iv) Digital display/ Indication (a) Lube oil pressure (b) Battery voltage (c) Engine RPM (d) Fuel level (e) Engine running hours indication (f) AC current and voltage (g) AC frequency (h) AC power metering (j) Suitable CTS for displaying the electrical parameters (v) Safety alarms required in the digital genset controller (a) High engine temperature (b) Low lube oil pressure (c) Low radiator water level (d) Low fuel level (f) under/over speed (vi) Safety trips required in the digital genset controller (a) High engine temperature (b) Low lube oil (D) BASE FRAME : Suitable to couple above engine & alternator made from steet sheel metal (E) FUEL TANK : 8 Hrs capacity with inlet & outlet arrangement, air vent & drain plug arrangement. (F) BATTERY:- One No battery of suitable capcity with battery leads. Note :- DG SET Engine & Alternator should carry warranty for period of 18 months
55 AVAITION OBSTRUCTION LIGHT: Supply and fix aviation obstruction LED type of Bajaj cat No 110731 BGAV 302 LED, 240 V, with timer switch and contactor inside the enclosure 4.00 EACH
56 supply and lay new high density polyethylene DWC pipes of 40mm dia, 6 kgf/sqcm ( For Avaition Obstruction & Dispersal area ligting) including all fittings (bends, Tees, Elbows, sockets, etc) as required on site, complete all as specified and directed. (For cable protection .) Note :- (i) Excavation, return filling and removal of any type of soil/ strata shall be measured and paid separately as items in the CA. 140.00 RM
57 REFRIGERATION & AIR CONDITIONING: Supply only voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of 2.5% and of capacity 4 KVA. 23.00 EACH
58 Supply only voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of 2.5% and of capacity 1 KVA. 10.00 EACH
59 CONDUIT FOR TELEPHONE & TV: S&F TV socket with metal box and top plate complete all as specified and directed. 15.00 EACH
60 S & F Telephone socket with metal box and top plate complete all as specified and directed. 15.00 EACH
61 INTERNAL ELECTRIC SUPPLY: (Other than Hangar) Supply and fixing LED Exit signage light fitting 3 Watt 230 V AC with 2 hr Battery Back up Make: Bajaj Cat Part No: BESL 03 LED SSD WBB Red/Havells/Wipro/Phillips 12.00 EACH
62 Supply and fixing LED Staircase signage light fitting 3 Watt 230 V AC with 2 hr Battery Back up Make: Bajaj Cat Part No: Staircase signage DSDWBB/ Havells/ Wipro/ Phillips 24.00 EACH
63 S & F BEE 3 star rated energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. 58.00 EACH
64 S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. 17.00 EACH
65 S & F energy efficient metallic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. 6.00 EACH
66 Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT Panel for Annex I of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides open able with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge.The Panel shall comprise of the following: 2.00 EACH
67 [A] BUSBAR CHAMBER [I] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection (B) Incomer - MCCB FP 200 A, 50 KA breaking capacity at 415 V,50Hz conforming to IEC-60942-2, having microprocessor based trip unit, adjustable over load setting (0.7-1 Xia), adjustable short circuit setting (5 - 10 Xire). adjustable neutral protection (N, N/2, OFF), front indication LED,s (ready, overload and pre-alarm)- 01No (C) Outgoing (i) MCCB FP 40A, 30 KA breaking capacity at 415 V, 50 Hz-03 Nos MCCB FP 63 A, 30 KA breaking capacity at 415 V, 50 Hz - 03 Nos (iii) MCB SP 25 Amp, C curve_01 Nos (D) LED Phase indicating lamp RYB - 01 set (E) Digital multifunction meter with KWH & karsh, voltage current, PF functions" (as per shown in drg CE(CG) Goa / Em- Han02- 1036/2022)
68 S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icon = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconvex IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed by engineer-in-charge.Make: Schneider, Legrand, Havells 6 A, SP MCB, C- curve 96.00 EACH
69 All as as per Item No 29.07 but 16 A, SP MCB, C- curve 50.00 EACH
70 All as as per Item No 29.07 but 20 A, SP MCB, C- curve 40.00 EACH
71 All as as per Item No 29.07 but 32 A, DP MCB, C- curve 100.00 EACH
72 Supply and fix PVC FRLS cable duct fixed on wall with un slotted type non slip cover including with all accessories including fixing plug, cable tie attachment, wire retainer mounting clamp angle/corner duct, channel ports etc with following size. (FOR COMMUNICATION CABLE) 100mmX50mm 600.00 RM
73 All as per item No 29.11 but 32mm x 20mm 800.00 RM
74 All as per item No 29.11 but 32mm x 16mm 600.00 RM
75 INTERNAL WATER SUPPLY: Supply & fixing 15mm dia Two way bib taps (Fancy type), cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron/CPVC pipes complete all as specified. 1.00 EACH
76 Supply & fixing of Health faucet with wall hook Make Hindware Model No F160027 or equivalent 15mm dia. 18.00 EACH
77 Sewage Treatment Plant: Design, supply, install and commissioning of package type 3KLD STP (Sewage Treatment Plant) including interconnecting pipes, valves, treated water pump, civil works, two nos raw sewage collection tanks with lifting pump of suitable capacity, Bar screen chamber, RCC/ PCC pedestals, Treated water tank of 1 KLD capacity with suitable capacity of pumping facility all as specified and directed. Note: (i) The entire scheme including under ground sewage line and manholes connecting Hangar No 1 & 2 shall be designed and vetted by any NIT/ IIT and approved by Accepting Officer before commencement of work. (ii) Treated water to confirm NGT norms before disposal to the area drainage system 1.00 EACH JOB