Tender for Military Engineer Services - NTID 31343831
Military Engineer Services
Visakhapatnam, Andhra Pradesh, India
NTID 31343831
- Opening Date : Thu 20th April, 2023
- Closing Date : Tue 18th April, 2023
- ₹ 5000000.00
- NTID 31343831
Provision Of 02 Additional Lifts (01 Lift Each) For Type Ii And Type Iii Quarters At Icgs Karaikal
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
100000.00 -
Document Cost
500.00 -
Estimated Cost
5000000.00
BOQ Items Total Items : 21 | Total Qty : 347
# | Item | Quantity | Units |
---|---|---|---|
1 | SCHEDULE 'A' PART - I (LIFT WORK) | ||
2 | Design supply, install, testing & commissioning passengers lifts, with capacity of 8 Nos passengers (544 Kg) , speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to ISI4665, suitable to serve G+06 upper floors with AC variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive(elecric motor driven mechanism) sliding stainless steel dooors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door and built-in Floor announcing system complete set complete all as complete all as specified and directed. The lift shall be provided with and including the following : (i) Battery operated emergency light (LED ceiling type) alarm (speaker for emergency alarm system) and stop button in car with rechargeable arrangement of battery.Call Register Signal and Vf Door Operator.(ii) Two sleek circular light fitting false ceiling d) One sleek circular PVC heavy duty fan in false ceiling (iii) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one more and top covering with PVC flooring complete. | 2.00 | Each |
3 | (iv) Non stop button/independent operation, Two way intecom with press & speak in COP (v) Overloading warning indicator visual type (vi) Front landing door of stainless steel moon rock finish operation with minimum time of 10 seconds and up to a maximum time of 30 seconds (vii) Car size shall be in confimity with IS-3534-1976 and body to be stainless steel of 16 gauge moonrock finish with stainles steel hand rail 38 mm hairline finish, provision for physically Handicaped and SS Braille Button with SS cover (viii) Set of there in number limit switches at bootom and top most position of lift hosit way as specified in lift IS and provide Pit ladder (ix) Specification plate with complete details and Lift Out of Order box (English and Hindi Language) (x) Continous earthing for machine and equipments (xi) Wire rope of adequate size as per relevent IS and as per manufacturer specification (xii) Other standard features and fittings like guide rails,sheaves, counter weights with guards, buffers gear unit breakes, control panel, locks governer, car operational panel, power control and trailing cables complete including demolition of existing brick work for door opening, plaster and painting match with existing surfaces at every floor as specified and directed by Engr-in-Charge. | ||
4 | Note for above item : The following items are deemed to be included in the quoted rate.(a) Car design:-Three side car walls finish in stainless steel hairline, car door finish in stainless steel hairline, car door in stainless steel finish, granite flooring finish in black sea, deco ceiling finish stainless steel hairline and full height mirror on rear car panel.(b) Car Operating Panel:-Stylish, touch sensitive glass panel, door open/ close and alarm buttons, visual call information, car position indicator, Pre- announcing arrows for controls and 16 segment display.(c ) Landing Doors:-Fully automatic landing doors in stainless steel hairline finish, door opening direction- centre.(d) Landing Operating Panel Stylish, resistance glass panel with touch sensitive glass. Call acceptance (visual), visual indication (fireman operation , reservation mode, overload and out of service)(e ) Standard Feature:-Close loop control system, self diagnostic system, 2hour fire rated landing doors, overload dection, automatic evacuation to nearest floor(ARD), light curtain on car entrance, alarm horn, handrail in stainless steel finish on rear wall, auto fan off and auto light off.(f) Other Selected Features:-CC TV cable preparation, intercom- 3 way, voices synthesizer on car, fireman control and FIGS120. | ||
5 | (g) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load.(h) Battery operated emergency light (LED ceiling fitting) alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery.(j) Decorative ceiling panel light (LED)(k) One sleek circular PVC heavy duty fan in false ceiling make for manufacturer.(l) continuous earting for machine and equipment.(m) Steel wire rope of adequate size as per relevant IS and as per manufacturer specification.(n) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes control panel, locks governor, car operational panel power control and trailing cables complete.(o) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. |