Tender for Haryana Government - NTID 30732912
Haryana Government
Faridabad, Haryana, India
NTID 30732912
- Opening Date : Thu 23rd February, 2023
- Closing Date : Wed 22nd February, 2023
- ₹ 6028500.00
- NTID 30732912
Providing Lifts, F.a.system, Servo Stabilizer, Cctv , Music System For Lifts, Spl. Repair To E.i., Automatic Power Factor Control Panel For Substation,ups For Meeting Hall And Security Light At Mini Sectt. Sec -12 Fbd. (repl Of Fire Alarm And P.a. System)
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
120570.00 -
Document Cost
5000.00 -
Estimated Cost
6028500.00
BOQ Items Total Items : 16 | Total Qty : 28023
# | Item | Quantity | Units |
---|---|---|---|
1 | FIRE ALARM SYSTEM SITC of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7 TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in charge of work Makes : Bosch FPA 5000 Series, Notifier NFS 3030 and Cerberus PRO by Siemens / Edward EST-3. | 1 | Each |
2 | SITC of Public Address System in Rack: consisting of the following 480W Amplifier to suitable size Make : BOSCH / HONEYWELL / EDWARD /Heinrich - 01 No. Selector & all facility for announcement of different floor - 01 Set Interface unit for integration of main fire alarm panel with public address system = 01 No. | 1 | Each |
3 | Supply, Installation, Testing & commissioning of Celling Mount Speaker with Plastic Mount or without mount as per site requirement for operation 6 Watts Make Honeywell/ BOSCH/Henrich | 32 | Each |
4 | SITC ofaddressable Heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required. Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Makes: Bosch / Siemens Cerberus / Notifier/ Edwards | 50 | Each |
5 | SITC of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Makes: Bosch / Siemens Cerberus / Notifier/ Edwards | 800 | Each |