Tender for Irrigation And Public Health Department - NTID 30656913
Irrigation And Public Health Department
Sundernagar, Himachal Pradesh, India
NTID 30656913
- Opening Date : Wed 8th February, 2023
- Closing Date : Wed 8th February, 2023
- ₹ 11372921.00
- NTID 30656913
Providing Laying Jointing And Testing Of Rising Mains Pumping Machinery With Allied Accessories For Zone No 1 Seri Kothi
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
146300.00 -
Document Cost
1500.00 -
Estimated Cost
11372921.00
BOQ Items Total Items : 9 | Total Qty : 7428.47
# | Item | Quantity | Units |
---|---|---|---|
1 | Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of each deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge. | 2076.47 | Cum |
2 | Providing , laying,jointing ( by way of circumfrential butt welded joints in three layers by electrical arc welding ) and testing of MS pipe of following dia meters confirming to ISO 3183-2012, steel grade of following class ERW (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe shall include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per IS:4736-1986 (with upto date ammendments) with mass of zink coating not less than 400 Kg/m2. The welding electrodes shall be as per IS 814:2004 of Advani Oerlikon/ L&T or ISI marked make. Negative tolerance in thickness and mass/weight of pipes will not be accepted. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer-in-charge with in all leads and lifts. (Earth work in trenches shall be measured and paid for separately).(i) 100mm dia API 3183-42L-290 5.20 mm wall thickness | 1000.00 | Rmt |
3 | (ii) 100mm dia API 3183-42L-290 4.80 wall thickness | 800.00 | Rmt |
4 | (iii) 80mm dia API 3183-42L-290 4.80 wall thickness | 900.00 | Rmt |
5 | Laying, jointing (by way of circumfrential butt welding joints by electrical arc welding) and testing of GMS pipe of following dia meters confirming to BIS 1239 (Part-I) grade specificed below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7meters including manufacturing reducers/tapers, all short pieces, bends etc. as per site requirement made from parent tubes. The laying of pipe will incluse all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer-in-charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS: 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of the Engineer-in-charge within all leads and lifts. (Earth work in trenches will be measured and paid for separately) (i) 100mm dia GI pipe (HG) 5.40 wall thickness | 800.00 | Rmt |