ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowProviding Installation Testing, Tekanpur - Tender Details
Explore tender information for Providing Installation Testing in Tekanpur, including eligibility, deadlines, and bid specifics.
BORDER SECURITY FORCE
Tekanpur, Madhya Pradesh, India
NTID 38917680
- Opening Date : Mon 20th January, 2025
- Closing Date : Sat 18th January, 2025
- ₹ 2014516.00
- NTID 38917680
Providing Installation Testing Commissioning Of Cubical Lt Panel And Ug Cable For Smp Shop At Tsu Bsf Tekanpur.
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
40290.00 -
Document Cost
Refer Documents -
Estimated Cost
2014516.00
BOQ Items Total Items : 17 | Total Qty : 1002
# | Item | Quantity | Units |
---|---|---|---|
1 | Supplying, installation, testing and commissioning of cubical type compartmentalized outdoor double door LT feeder pillar suitable for 415V, 3Phase, 4 wire 50Hz AC supply system. Panel should be factory fabricated in an approved factory having modern fabrication and testing process . It shall have seven tank pretreatment process comprising of degreasing, rinsing ,de-rusting ,rinsing, phosphatizing ,rinsing and passivation followed by powder coat painting(shade: Siemens Grey RAL 7032) having a paint thickness of 60 microns . panel should be provided with suitable gasket to make it dust/vermin proof. Panel should be IP 54 protected .The Size of panel not less than 0.96 Cum, front surface area not less than 2.4 sq. mtr made with 2 mm CRCA sheet and having detachable 3 mm thick CRCA gland plate, with 400 Amp capacity TPN aluminum bus bar base of insulated brackets or studs as per norms. The panel should be suitable to accommodate 05 nos MCCB of various rating, 08 Nos 4P MCB, LED indicators, Multifunction meter etc. as reqd, Suitable backlite sheet arrangement for insulation of MCCB and other switch gears and locking arrangement, hinges of the doors should be as required. The panel should be openable from two sides back & front sides should be fixed with hinges and lock as reqd, and having 300 mm height with 2 mm sheet on the base frame in all sides fixed on outer existing base frame with nut bolts. Inter link arrangement with suitable size bus bar should also be arranged accordingly to MCCB and other switch gears in all respect. (panel shall be made from CPRI approved manufacturers) The drawings will be final as per direction of Engineer-in-charge. the panel should be mounted on 50 mm x 50 mm x 6 mm GI Angle frame having length 0f 1200 mm (600 mm above ground level and 600 mm for foundation). Providing and laying in position cement concrete 1:3:6 (1 cement: 2 coarse sand: 6 graded stone aggregate 20 mm nominal size) in foundation of feeder pillar including form work etc. as required. The following panel mounting Switchgears etc complete as required. 1) Panel dimensions :- 1600 mm x 1500 mm x 400 mm = 2.4 Sqm 2)For Incoming:- a) 250Amp MCCB, , thermal & magnetic setting , Breaking Capacity Ics=100%Icu at 415 Volt AC, 50 Hz- 50 KA, 4 pole, including Spreaer Terminals Make L&T ( D sine) /Hevells/Legrand cat No. 4202 79 Qty - 01 No. 3) For Outgoing:- a) 160 Amp Amp MCCB, , adjustable thermal & fixed magnetic setting , Breaking Capacity Icu at 415 Volt AC, 50 Hz- 36 KA, 4 pole, including Spreder Terminals Make L&T ( D sine) /Hevells/Legrand cat No. 4200 97 Qty - 01 No. b)100 Amp MCCB, , adjustable thermal & fixed magnetic setting , Breaking Capacity Icu at 415 Volt AC, 50 Hz- 36 KA, 4 pole, including Spreder Terminals Make L&T ( D sine) /Hevells/Legrand cat No. 4200 95 Qty - 03No. (c) 63 Amp 4P C Curve MCB sort circuit Breaking capacity -10 kA (10 kA ISI marked as per IS/IEC 60898-1 2002) Make L&T /Hevells/Legrand cat no. 4087 02 Qty - 08 No 4) For Metering:- a) Three phase multifunction meter having following features, Accuracy Class 0.5, Input voltage measurement range 50-520 VAC, Aux supply 80-300 VAC/DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, CT/PT site programmable, V, A, F, PF, kW, kVA, Old energy, On and Run hours, site selectable kWh/ kVAh, True PF or Displacement PF site selectable etc. as required. Make ABB/Siemens/Snieder/L&T cat No. WL440531OOOO b) Metering Current Transformers Busbar Type 400/5A rating secondary current 5A, Primary current 400A, class 0.5, 15VA, Make: L&T/Rishabh/Hager/Matrix/Fuji electric c) LED indicators having colour Red, Yellow &Blue and operated on 240 Volt AC,Cat No-TTO, L&T Make - 01 | 1 | Job |
2 | Supplying, installation, testing & commissioning of outdoor canopy type CPRI approved Both side openable double door MV Cable Joint Box with pad-locking arrangement, hinge type door of size 600mm (L) X 500mm( H)X 400mm (D) fabricated out of 2 mm thick CRCA steel sheet with siemens grey colour shed, mounted on GI angle frame with nut & bolt , door cover provide with synthetic gaskets, Earthing studs at both side of box, cable entry & gland plate provide in bottom - suitable for 3 X 240 sq.mm PVC UG cable , including providing and suitabley fitted 4 Nos 400A capacity aluminum bars on DMC insulator & pvc coloured cover sleeves on bus bar, including 4 nos 50mm X 50mm X 6mm, 1000 mm (3.37 ft) GI angle hight each of four Leg, out of 1.5 ft will be under the ground , connections, earthings i/c installation by cement concrete and masonery bricks build leg angle foundation etc as reruired. | 1 | Job |
3 | Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 160 mm dia (OD-160 mm & ID-135 mm nominal) | 390 | Mtr |
4 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 kV grade of size 4CX 240 Sq mm in the existing RCC/ HUME/ METAL/HDPE pipe as required. Make of Cable havells /Polycab. | 440 | Mtr |
5 | Providing and laying of one number PVC insulated and PVC sheathed / XLPE aluminium conductor armoured power cable of 1.1 KV grade of 4C X 240 sq mm size in the existing masonry open duct as required. | 10 | Mtr |