Tender for BORDER SECURITY FORCE - NTID 29975024
BORDER SECURITY FORCE
Ganganagar, Rajasthan, India
NTID 29975024
- Opening Date : Tue 6th December, 2022
- Closing Date : Mon 5th December, 2022
- ₹ 525883.00
- NTID 29975024
Providing And Fixing Of Air Cooling System At Adm Block And Jawan Barrack At New Location Of 125 Bn Bsf Under Shq Bsf Sgnr
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
10518.00 -
Document Cost
Refer Documents -
Estimated Cost
525883.00
BOQ Items Total Items : 7 | Total Qty : 2668
# | Item | Quantity | Units |
---|---|---|---|
1 | Supplying and fabrication of cooler body size 32'' x 40 '' x 60 '' made of 18 guage GI sheet including fixing of 0.5 HP exhaust fan of 600 mm (24'') sweep size having 900 RPM suitable for 230 Volt, 50 Hz, AC supply make Crompton/Bajaj/Usha including cooler submersible pump of 40 watt make Premium/crompton or equivalent. Cooler will be mount on the stand size of 32x 40x 6'' height, stand will be fabricated by angle iron of 50x50x5 mm, 04 No. ducting grill of Size (12x 18 Inch). Remote humidity control for submersible pump and cooler motor for fixing in the cooler body complete set etc. as required as per direction of Engg- In - Charge. | 7 | Each |
2 | Suppling and making of ducting through 22 Gauge GI sheet with duct face size 18"x 12", ducting will be insulated through high quality thermal insulating material etc as required as per direction of Engineer- in- Charge. | 995 | Sqft |
3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 52 | Mtr |
4 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole and neutral | 7 | Each |
5 | Cutting of RCC wall manually or by mechnical means I/C taking of steel bars and disposal of unserviceable material and repairing of damaged wall after dismanteling/cutting including plastering etc as complete as per the direction of Engineer-in-charge | 7 | job |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane