ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry Now
2 Nos Of New Cold-room Works F, Kochi - Tender Details
Explore tender information for 2 Nos Of New Cold-room Works F in Kochi, including eligibility, deadlines, and bid specifics.
COCHIN INTERNATIONAL AIRPORT LTD.
Kochi, Kerala, India
NTID 39377760
Opening Date : Wed 12th March, 2025
Closing Date : Tue 11th March, 2025
- ₹ 4432000.00
- NTID 39377760
2 Nos Of New Cold-room Works For The Export Cargo And Modification Of Temperature Controlled Rooms In Duty-free Warehouse Cial
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
88640.00 -
Document Cost
Refer Documents -
Estimated Cost
4432000.00
BOQ Items Total Items : 18 | Total Qty : 720
# | Item | Quantity | Units |
---|---|---|---|
1 | New Coldroom 1 and 2 - Export Cargo | ||
2 | SITC of 6 kW DX Split unit for the cold room 1 at the Export cargo. The room temperature to be maintained is 2-8 C. The ambient temperature to be considered is 40 C. Each indoor unit (COIL: Al fin and Cu tube) shall contain min 2 fans of min 300mm. Refrigerant shall be R404a/R407c. The outdoor unit shall contain Hermitically sealed Scroll compressors. It should contain a suitably rated starter panel, and power wiring from DB/isolator with all accessories.The compressor on/off based on the load shall be controlled by a microprocessor-based control panel with an automatic digital display of temperature and humidity and shall be provided near the sliding door in each compartment. It sjhall also includes up to 20ft of interconnecting pipe and wire between each Indoor and Outdoor unit. Insulation for pipelines should be 25mm thick closed cell elastomeric class 0 insulation with 7 mils woven fibreglass cloth covering adhered between two coats of fungicidal protective coating. CPVC drain pipe of suitable size connecting drain lines from indoor to drain sump outside the building with suitable insulation. Platforms for Indoor and Outdoor units shall be with vibration isolator pads. Both the Indoor and Outdoor unit cabin should be made of PCGI casing and the Outdoor unit should be IP54 rated. Charging of gas, and safety devices like thermal protectors, pressure relief valves, overload relays, single phase preventers, high-low pressure cut off, earth connections, DB, and Power sockets as per Kerala State Electricals Inspectorate guidelines suitable for 3-phase 440v incomer supply. Room size: 4m*2.5m*3.5m Note: The proposed quantity is 1W and 1S | 2.000 | Nos |
3 | SITC of 8kW DX Split unit for the cold room 2 at the Export cargo. The room temperature to be maintained is 2-15 C. The ambient temperature to be considered is 40 C. Each indoor unit (COIL: Al fin and Cu tube) shall contain min 2 fans of min 300mm dia. Use refrigerant R404a/R407c. The outdoor unit shall contain Hermitically sealed scroll-type compressors. It shall contain a suitably rated starter panel, and power wiring from DB/isolator with all accessories. The compressor on/off based on the load shall be controlled by a microprocessor-based control panel with an automatic digital display of temperature and humidity and shall be provided near the sliding door in each compartment. It also includes up to 20ft of interconnecting pipe and wire between each Indoor and Outdoor unit. Insulation for pipelines should be 25mm thick thick closed cell elastomeric class 0 insulation with 7 mils woven fibreglass cloth covering adhered between two coats of fungicidal protective coating. CPVC drain pipe of suitable size connecting drain lines from indoor to floor sump with appropriate insulation. Platforms for Indoor and Outdoor units shall be built with vibration isolator pads. Both the Indoor and Outdoor unit cabin should be made of PCGI casing and the Outdoor unit should be IP54 rated. Charging of gas, and safety devices like thermal protectors, pressure relief valves, overload relays, single phase preventers, high-low pressure cut off, earth connections, DB, and Power sockets, as per Kerala State Electricals Inspectorate guidelines suitable for 3-phase 440v supply. Room size: 4m*5m*3.5m Note: The proposed quantity is 2W and 1S | 3.000 | Nos |
4 | SITC of Wall and Ceiling Insulation panels for Cold Rooms 1 and 2 at the Export cargo. Pre-fabricated panels with RPUF of a minimum density of 40kg/m3 should be used. It should have heat conductivity less than 0.023 W/m C at 10 C. The panel should be of a thickness of 80mm. The material used to sandwich RPUF should be PPGI sheets of 0.5mm thickness. Panel-to-panel locks shall be cam-lock with tongue and groove assembly. 90 Corner panels should be used for corners. The wall-to-ceiling joinery shall be held using flashing from inside and outside. All joints should be silicon-sealed. The panel should have grooves for increased strength. RPUF material should strictly adhere to the IS standard 661. The panels shall have Fire self-extinguishing/Fire-resistance/ Fire retardant properties. Room size of C1 is: 4m*2.5m*3.5m (L*W*H) Room size of C2 is: 4m*5m*3.5m (L*W*H) | 154.000 | m2 |
5 | SITC of Floor Insulation panels for Cold Rooms 1 and 2 at the Export cargo. The flooring shall be a 60 mm PUF slab with a Tar felt sheet of minimum 2mm thickness (concrete flooring, customer scope). | 35.000 | m2 |

Purchase Access To Download Selected Documents
₹ 200
Select this Plan

For a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054