Miscellaneous Repair Of Guniting Work Incl Ceiling Repair, Joinery Work Of Steel And Aluminum, Hardstanding Sanitary And Plumbing Work Incl Roof And Sunken Treatment In The Aor Of Age Br Kashmir House Under Ge New Delhi
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
186000.00 -
Document Cost
1000.00 -
Estimated Cost
11100000.00
BOQ Items Total Items : 92 | Total Qty : 19867.25
# | Item | Quantity | Units |
---|---|---|---|
1 | Demolition of old damaged existing water proofing compound on RCC roof of any description in any position and specification and cleaning the surface thoroughly and removing materials from site of work and providing the following works :- (a) Over 15 mm thick screed bed in cement mortar 1:4 on roof surface or concrete surfaces, finished even and smooth (without using extra cement) mixed with WPC (200ml per 50kg of bag cement) all as specified and directed. (b) Applying evenly a coat of bitumen primer @ 0.50 Kg/Sqm. (c) Applying APP modified polymeric membrane over the bitumen coat surface ,weight not less than 3.0 Kg/Sqm and over lap 100mm and sealed by torch application as per manufacture instructions. (d) Sealing edges well into grooves & protect with CM 1:2 complete all as specified and directed. (e) Applying aluminium paint @ 200 gm/sqm in two coats over polymeric membrane at non approachable roof all as specified and directed | 570.000 | Sqm |
2 | M&L for surface Preparation: The surface to receive the treatment shall be thoroughly free of laitance, scales, oil or any other loose material. It should be made free of any sharp objects. Cleaning of PCC/plaster surface shall be done with wire brushing to attain smooth levelled surface. Cracks shall be rectified, filled using dual shrinkage compensated Repair Mortar and dried for 72 hours before laying the liquid applied membrane. Grout: Providing Chemical injection treatment in the form of pressure grouting to the construction joint and cracked portion at 1m c/c by injecting cement slurry mixed with dual shrinkage compensated cementitious grout Injection grout additive, in the required consistency through the pre fixed PVC nozzles in the 18 mm dia holes, fixing of PVC nozzles with instant setting cement. Angle fillets/Coving: Providing and making of fillet, 50mm x 50mm on sharp corner of terrace with cement sand polymer mortar (add multipurpose mortar , 10% by weightofcement). First apply the bonding coat of Multi-Purpose Polymer 5-10% diluted in water and add to cement slurry. Apply the bonding slurry and apply the polymer mortar over the sharp edges complete all as specified and directed. Note: Grouting will be done when and where ever required. Treatment of pipe entry points: Preparing the inside surface of core and PVC /MS Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Packing the gap using free flowable non shrink cement polymer based grout up to the surface of the bore while the bonding agent is in tacky state. the periphery of PVC pipe should be sealed with Hybrid PU Sealant or dual shrinkage compensated Micro concreteNote: Will be done when and where ever required Application of Asian Paints two component Epoxy Primer (Resin & Hardener) on the cleaned surface for bonding of Polyurethane with the existing concrete surface. 33 % water dilution is recommended with the pure mixed primer. The primer mixing ratio will be 1:3(Resin:Hardner) Supplying, providing and applying waterproofing treatment to Podium area with single component highly elastomeric seamless cold applied modified PU coating complete as per manufacturer s specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1mm. The coating shall have a dual combination of 280% elongation. Material coverage 1.2kg /sq.mt. | 100.000 | Sqm |
3 | M & L for Cement concrete 1:3:6 type C1 using 20mm graded stone aggregate in plinth protection, 75mm thick, finished fair and even without using extra cement, complete. | 50.000 | Sqm |
4 | Taking down cement or cement lime plaster any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed including removal of debris out side MoD land. The work shall be carried out upto sixth storey height of buildings. | 1500.000 | Sqm |
5 | M&L for 15mm thick ready mix plaster READIPLAST RP of (Make Ultra tech) on any surfaces of brick/concrete includidng aapplication of bonding coat as Ultratech seal and Dry 5 Plus as per manufacturers instruction including finished even and smooth complete all as specified and directed.The work shall be carried out upto sixth storey height of buildings including all safety factor. | 1300.000 | Sqm |