Tender for Kerala State Housing Board - NTID 30773624
Kerala State Housing Board
Trivandrum, Kerala, India
NTID 30773624
- Opening Date : Mon 20th February, 2023
- Closing Date : Sat 18th February, 2023
- ₹ 11761924.00
- NTID 30773624
Kshb - Kiifb - Hvac Works For The Development Of Government Taluk Hospital Thuravur, Alappzuha District
Documents
Unlock the opportunities
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
50000.00 -
Document Cost
5900.00 -
Estimated Cost
11761924.00
BOQ Items Total Items : 70 | Total Qty : 4485
# | Item | Quantity | Units |
---|---|---|---|
1 | AIR CONDITIONING WORKS | ||
2 | od335499/2022_2023 : DX System: Supply installation testing and commissioning of DX(direct expansion) outdoor units with scroll compressors. Air-cooled DX outdoor unit @ 43 Deg C ambient condition with one or two scroll compressors of equal capacity, air-cooled condenser coils, condenser fans with weatherproof motors, safety controls, the microprocessor-controlled starter for evaporator fans, etc. An electrical point will be provided nearest to the unit. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, and low noise condenser fan. The Refrigerant shall be R - 410 A. The unit shall be supplied with all accessories as required suitable for AHU connectivity. For 2TR units, rotary or reciprocating compressors can be considered if scroll compressors are not available. for 11TR out door units (CT scan-1W+1S) | 2.0000 | no |
3 | od335500/2022_2023 : DX System: Supply installation testing and commissioning of DX(direct expansion) outdoor units with scroll compressors. Air-cooled DX outdoor unit @ 43 Deg C ambient condition with one or two scroll compressors of equal capacity, air-cooled condenser coils, condenser fans with weatherproof motors, safety controls, the microprocessor-controlled starter for evaporator fans, etc. An electrical point will be provided nearest to the unit. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, and low noise condenser fan. The Refrigerant shall be R - 410 A. The unit shall be supplied with all accessories as required suitable for AHU connectivity. For 2TR units, rotary or reciprocating compressors can be considered if scroll compressors are not available. for 5.5TR out door units(Minor OT) | 1.0000 | no |
4 | od335501/2022_2023 : DX System: Supply installation testing and commissioning of DX(direct expansion) outdoor units with scroll compressors. Air-cooled DX outdoor unit @ 43 Deg C ambient condition with one or two scroll compressors of equal capacity, air-cooled condenser coils, condenser fans with weatherproof motors, safety controls, the microprocessor-controlled starter for evaporator fans, etc. An electrical point will be provided nearest to the unit. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, and low noise condenser fan. The Refrigerant shall be R - 410 A. The unit shall be supplied with all accessories as required suitable for AHU connectivity. For 2TR units, rotary or reciprocating compressors can be considered if scroll compressors are not available. for 3TR out door units(ICU) | 2.0000 | no |
5 | od335502/2022_2023 : DX System: Supply installation testing and commissioning of DX(direct expansion) outdoor units with scroll compressors. Air-cooled DX outdoor unit @ 43 Deg C ambient condition with one or two scroll compressors of equal capacity, air-cooled condenser coils, condenser fans with weatherproof motors, safety controls, the microprocessor-controlled starter for evaporator fans, etc. An electrical point will be provided nearest to the unit. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, special acryl precoated heat exchanger, and low noise condenser fan. The Refrigerant shall be R - 410 A. The unit shall be supplied with all accessories as required suitable for AHU connectivity. For 2TR units, rotary or reciprocating compressors can be considered if scroll compressors are not available. for 11TR out door units (OT-1-2-3) | 3.0000 | no |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane