Electrical Wiring With Other Associated Work Iro Haringhata 33 Kv Substation At Haringhata Under Kalyani Division
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
10290.00 -
Document Cost
Refer Documents -
Estimated Cost
514482.00
BOQ Items Total Items : 34 | Total Qty : 3367
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply,delivery,fittings,fixing & electrical connection of 433 volt AC Distribution Board (Including freight,insurances,incidental charges , Taxes,Duties , Cess etc as applicable) as per technical specification of WBSEDCL and Indiian Standard. 1.Size: 1000mm(H) X 750(W) mm X 300(D) mm. 2.Panel shall made of 2 mm thick Steel Sheet. 3.Colour of the Panel shall be of "Siemens" Light Grey in Power Coated. 4.Bus bar shall be tinned electrolytic Copper with Continous current rating of 200A with minimum size 30mm X 5mm & without Joint as per IS standard and shall be supported by flat Insulator. 5.Panel Shall be properly Gasketed for dust and vermin proof (IP-54 Type) 6.Control wiring shall be done by 6/4/2.5 Sq.mm. flexible copper cable "FR" 650/1100 KV Grade .(Havell's Make) 7.Havell's make 200A TPN SFU with 200A HRC fuse link Cat Code:IHFSTF4200-1 NO (Incomer) 8.Havell's make TPN MCB 32 AMP - 4 Nos. (For Water Supply,Outdoor Light,Yard Light , & Spare - 1 no's.) 9.Havell's make TPN MCB 16 AMP - 4 Nos. (For OLTC - 2 no's , & Spare - 2 no's.) 10.Havell's Make DP MCB 32 AMP - 4 NO'S (For Indoor Light & Indicating Lamp - 1 no , Battery Charger 1- 1 no , Battery Charger 2 - 1 no & Spare- 1no) 11.Havell's make DP MCB 16 AMP - 8 NO'S (For AC Supply - 2 nos (33kV & 11kv Panel - 1 each) , RTU & UPS - 1 each , RTCC - 2 no's , Spare- 1 no's) 12.AE make AC Ammeter of 0-200A range,flush mounting ,Size-96x96mm,analog type ,5/1A operating current from CT Secondary with KAYCEE make selector Switch - 01 no. 13.AE make AC Voltmeter of 0-600V range,flush mounting ,Size-96x96mm,analog type ,5/1A operating current from CT Secondary with KAYCEE make selector Switch - 01 no. 14.KAPPA make 200/5A Tape Insulated Current Transformer - 4 no's 15.VISHNO make 230V AC Indicating Lamp (R , Y & B - 1 each) 16.100X100 mm Size Danger Board with details as per standard Size. | 1.00 | NO |
2 | Supply,delivery,fittings,fixing & electrical connection of 433 volt DC Distribution Board (Including freight,insurances,incidental charges , Taxes,Duties , Cess etc as applicable) as per technical specification of WBSEDCL and Indiian Standard. 1.Size: 1000mm(H) X 750(W) mm X 300(D) mm. 2.Panel shall made of 2 mm thick Steel Sheet. 3.Colour of the Panel shall be of "Siemens" Light Grey in Power Coated. 4.Double bus arrangement with change over switch with provision for one set of +ve and ve connected to Charger-1 and another set of +ve and ve connected to Charger-2.Bus bar shall be tinned electrolytic Copper with Continous current rating of 200A without Joint as per IS standard and shall be supported by flat Insulator. 5.Emergency lighting circuit shall be provided such that the lights normally burn on AC 240 Volts, 50 Hz but in case of failure of AC supply, these come up on DC supply with the help of automatic change over contactors and again change over to AC supply with the restoration of AC supply. There shall be two number double pole ON/OFF switches with HRC fuses one each for AC and DC supply. 6.Panel Shall be properly Gasketed for dust and vermin proof (IP-54 Type) 7.Internal wiring of DCDB shall be done as per technical specification and Indian Standard. 8.Havell's make 100A DP DC MCCB with Thermal Over Load Trip - 1 no incomer. 9.Havell's make DP DC MCCB 16 AMP - 16 Nos. (11kV - 4 no's , 33kV - 7 no's , Scada Equipments - 1 no , Emergency Illumination of Control Room - 1 no , Spare- 3 no's.) 10..AE make DC Ammeter of 0-30A range,flush mounting ,Size-96x96mm,analog type - 1 no 11.AE make DC Voltmeter of 0-40V range,flush mounting ,Size-96x96mm,analog type - 1 no 12.Siemens Make 30V DC Earth Fault Alarm Relay - 1no 13.Siemens Make Mains Fail Alarm Relay - 1 no 14.30V DC Buzzer of reputed Make - 2 no's 15.Vishno Make 30 V DC RED Indicating Lamp - 2 no's 16.VISHNO Make Push button - (Yellow & Blue) - 2 nos 17.GE Make 2A HRC fuse link with base - 2 Nos 18.GE Make 16A HRC fuse link with base - 32 Nos 19.GE Make 30V DC Axiliary Contactor with 2NO+2NC - 4 no's 20.100X100 mm Size Danger Board with details as per standard Size. | 1.00 | SET |
3 | Earthing with copper plate (610 x610 x3mm size) having waight of 9.84 kg and 1 no 25 x5 mm copper strip (3.20 mtr long ) & 1 no 6 sq mm PVC Insulated stranderd copper wire ( 4 mtr long) incel S& F 15 mm dia GI Pipe ( ISI MEDIUME) Protation( 4 mtr long to filled wich bitumen partly under the ground level & restrorin the surface duly rammed and providing 3.0 mtr long 25 mm dia GI Pipe (5 mediume) for perliodic treatment incl. providing masonery enclusare on the trip other earth electrod of over all size 8636 x8636 x 46 mm deep ( bellow ground leavel completed with concreted with brick work (1.6 of 25 cm with duly plastered with cement moster ( inside) CI INSPECTION COVER OF SIZE 36.56 X36.56 CM WITH Locking arrangement GI reducer and treatment of soil by using solt & charcoal or etc for plate electrod. | 2.00 | NO |
4 | Suppling & fixing earth busber of galvonaized (hot dip) ms flat 40 mm x 6 mm on all having clerance of 6 mm from wall including providing drilled holles on the busber completed with GI Bolt nuts washer spacing including etc as per required. | 2.00 | Mtr |
5 | Connecting the equipments body to earth bushber incl. S&F 25 mm x 6 mm Galvanised (hot dip) ms flat on ground floor with gi saddel as required and connection to equipments incl. Driling holes , with bolts , nuts , etc. | 70.00 | Mtr |