Corrigendum Vrv-centralized , Imphal - Tender Details
- Opening Date : Fri 28th March, 2025
- Closing Date : Thu 27th March, 2025
- ₹ 7267675.00
- NTID 39699255
Tender Description
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
145354.00 -
Document Cost
1000.00 -
Estimated Cost
7267675.00
BOQ Items Total Items : 64 | Total Qty : 3931
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply , installation, tetsing and commissioning of modular typeVariable refrigerant flow/ voloum aue cool outdoor unit suitable for coolong and heatiing having all hermitically sealed inverter type scroll compresssor ,minimum two compressors for above 14 HP modules , microproccessor base controller ,top discharge type condensing units , with R 410 A Refregerent, vivration isolator s, with suitable foundation etc. complete as reqd.the unit shall deliver the rated capacity at AHRI conditions and work even at 50 degree ambient temp. without tripping . THe unit shall be suitable to work on 440 V +/- 10 % , 3 phase, 50 HZ AC power supply . THe unit shall be filled with first charge of the refregerent and ready for use as reqd. THe COP at AHRI condition shall not be less then 3.1 and IEER not less then 6.5 as reqd. | ||
2 | 22 HP (Inclusive of ODU Refnet) | 22.00 | per HP |
3 | 12X2 HP (Inclusive of ODU Refnet) | 24.00 | per HP |
4 | 16X 2 HP (Inclusive of ODU Refnet) | 32.00 | per HP |
5 | VRV INDOOR UNITS - FLOOR MOUNTED AIR HANDLING UNIT Supply, Installation, Testing & Commissioning of sheet metal sectionalised construction double skin air handling units with 50 mm thick injected PUF of density not less than 40 Kg/CuM with thermal break profile. The air handling units shall be complete with pre-filter section with synthetic fibre filters and MERV-13 & MERV 8 filter, coil section with multi rows deep DX cooling coil of copper tube & aluminium fin construction, fan section complete with EC fan suitable for total static pressure as detailed below, IE-02 motor, insulated stainless steel drain pan and vibration isolation arrangement all complete as per specifications. AHUs shall be selected for a maximum face velocity of 400 FPM. The units shall be compatible with VRF outdoor units. |
Purchase Access To Download Selected Documents
₹ 200
Select this PlanFor a one-time fee, you get unrestricted access to all documents and for a minimum of one year.
UNLIMITED
DOWNLOAD
Select this Plan
₹ 7000
Plan
Standard Plane
Day/Month
Standard Plane
Sales: +91 7383 93 4054