ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry Now
Corrigendum Hvac Works Of Cr, Ernakulam - Tender Details
Explore tender information for Corrigendum Hvac Works Of Cr in Ernakulam, including eligibility, deadlines, and bid specifics.
KITCO Limited
Ernakulam, Kerala, India
NTID 39291429
Opening Date : Fri 28th February, 2025
Closing Date : Wed 26th February, 2025
- ₹ 7740000.00
- NTID 39291429
Corrigendum : Hvac Works Of Critical Care Block At Govt Medical College Manjeri
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
50000.00 -
Document Cost
2950.00 -
Estimated Cost
7740000.00
BOQ Items Total Items : 52 | Total Qty : 2606
# | Item | Quantity | Units |
---|---|---|---|
1 | HVAC WORKS | ||
2 | od248323/2022_2023 : Supply, Installation ,testing and commissioning of 30 HP minimum capacity Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between IDUs, ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units). | 1.0000 | no |
3 | od248324/2022_2023 : Supply, Installation ,testing and commissioning 18 HP minimum capacity Air-cooled VRF (Variable Refrigerant Flow) Outdoor unit with variable speed inverter driven multiple compressors complete with suitable capacity drive motors conforming to IE3 as per IS 12615, air cooled condenser, R410A/R407C refrigerant, oil separator, with all accessories, and safety devices like thermal protector, pressure relief valve, high-low pressure cut off etc . Necessary structural supports, ODU vibration isolators shall be considered . Equipment shall be suitable for 3 phase, 415 V, 50Hz supply along with suitably rated starter panel & associated accessories, suitable interconnecting control cabling between IDUs, ODUs ,power cabling between isolator and single/multiple outdoor units along with associated electrical accessories. Required supports including structural supports /RCC/ cement concrete foundation shall be included as part of equipment . COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. The efficiency of the equipment shall meet ECBC/ASHRAE latest standards etc. complete in all respects as per the technical specifications.(single feeder power source will be provided for outdoor units). | 1.0000 | no |
4 | od248333/2022_2023 : Supply, Installation , testing and commissioning of the following capacity VRF compatible Air handling units with AHU Kit with all standard fittings, outlet volume control dampers, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/Sq.ft. of coil surface area for equal distribution, filter section shall comprise of prefilter The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) and bag filter of 99% efficiency down to 3 micron (MERV 13) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement flexible connectors, IDU SS drain pan, as per specifications complete with power wiring, suitable capacity drive motor conforming to IE3 as per IS 12615, electrical controller, temperature controller with digital display, thermostat, control wiring, complete with necessary vibration isolators, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, PVC drain pipe connections(upto 5 m) with 9mm thick round nitrile rubber insulation finished with 7 mils woven fibre glass cloth covering adhered between two coats of fungicidal protective coating, including U-trap along with necessary elbows, fittings etc ,power/control cabling from power supply, etc. complete in all respects as per technical specifications.<br>20TR (8000 CFM) - 50 mm of WG ESP | 1.0000 | no |
5 | od248336/2022_2023 : Supply, Installation ,testing and commissioning of following minimum capacity Double skin, sheet metal VRF compactable Ceiling Suspended Unit including AHU kit, all accessories as required as per technical specifications complete with outlet volume control dampers, canvas connections, UV Emitters with reflectors to be fixed on the coil surface with removable extruded aluminium frames. UV emitters shall be minimum 12watt/Sq.ft. of coil surface area for equal distribution, The efficiency of the filters shall be 90% down to particle size of 10 microns (MERV-8) and bag filter of 99% efficiency down to 3 micron (MERV 13) filters complying to ASHRAE 52.2 , cooling coil of copper tube and aluminium fin construction, drier, first charge refrigerant gas of R410A/407C, IDU SS drain pan, squirrel cage, TEFC, 3-Ph induction motor, DIDW centrifugal fan, drive package and cushy-foot mounting, all housed inside housing of a double skin construction AHU with vibration isolation arrangement, power wiring and power/control cabling(indoor to outdoor),digital thermostat with required control wiring, required starter and starter panel , structural supports for fixing IDU, safety devices etc. the following minimum capacity and the cooling coil (min 4 rows), suitable for three phase 440V supply, complete in all respects as per technical specifications.(Minimum External Static Pressure 25 mm of WG )8 TR-3200 CFM - 25 mm of WG ESP | 1.0000 | no |