ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowCorrigendum Design Supply , Pune - Tender Details
Explore tender information for Corrigendum Design Supply in Pune, including eligibility, deadlines, and bid specifics.
Indian Institute of Science Education and Research
Pune, Maharashtra, India
NTID 38796089
- Opening Date : Mon 20th January, 2025
- Closing Date : Sat 18th January, 2025
- ₹ 5600000.00
- NTID 38796089
Corrigendum : Design , Supply And Erection Of Weather Covering To Courtyard At Faculty Housing Building A And B At Iiser Pune.
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
112000.00 -
Document Cost
1180.00 -
Estimated Cost
5600000.00
BOQ Items Total Items : 8 | Total Qty : 21151
# | Item | Quantity | Units |
---|---|---|---|
1 | BOQ Part-A: Designing and Proof Checking : The L1 bidder shall submit the structural design and drawings, along with proof-checking documents and quantification of steel quantity, within 15 days from the issuance of the acceptance letter. After receiving clearance from the Engineer-in-Charge , IISER Pune, the proof-checking of the design and drawings must be completed within 15 days. The work order will be issued upon successful submission and approval of the proof checked design and drawings by the Engineer-in-Charge. Failing to meet the specified timelines will result in the cancellation of the issued acceptance letter. | ||
2 | DESIGNING AND PROOF CHECKING : Design and proof checking of structural steel designing of Skylight roofing for supporting multiwall polycarbonate sheet work based on the existing RCC structural design. Structure shall be designed as per latest IS codes and shall sustain all types of weather conditions without any leakages / damages. Shape of the Skylight roofing shall be as shown in the drawing/as per instructions from Engineer In-charge. Proof checking of structural steel design along with load analysis by considering self weight of structure , weight of roofing , wind and seismic loads shall be considered during the the design of structure. Proof Checking shall be carried out from any one of IIT's / NIT's/COEP / VJTI. Bidder to refer structural layout provided by IISER Pune for skylight roofing design purpose. Bidder shall submit MS memberwise tonnage quantity along with the proof checked drawing and design. Bidder will have to submit structural design along with drawing and input file of structural design software before proceeding for proof checking.Structural Design and drawing is required for Faculty Housing-A and Faculty Housing B two identical building , two and two indentical structural designs to be made based on actual sizes at site at different buildings. | 1.00 | each design |
3 | PART-B : STRUCTURE FABRICATION AND ERECTION WORKS | ||
4 | Supply, erection and fabrication of structural steel work of minimum grade FY250 riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing, bending, curve shaping as per design in position and applying a priming coat of approved steel primer all complete. Quoted rate shall be including providing and fixing the anchoring/holding down bolts of HILTI make as per structural design requirements on exiting RCC column/beams/ Brackets / Clamps including fastening straps, nuts, bolts, rivets, washers etc. as per proof checked design requirements and as per approved shop drawing. Brackets / Clamps shall be of hot dip galvanized steel and Fastening materials shall be Non - magnetic Stainless steel 300 series - 316 grade of Hilti make or approved make. Galvanizing thickness shall be in accordance with IS 2629 and 4759. Providing and fixing Serrated plates or Serrated washer wherever required as per the system requirement and as shown in the approved shop drawing complete as per direction of Engineer in charge. Structural steel design as approved by IIT or COEP shall be referred for the erection purpose. Quoted rate shall include the cost of all materials, labour, cost of holding down bolts, fasteners, nuts & bolts, all operations and process specified above, all wastages, steel scaffolding, infrastructure facility, tools and plants, all taxes, central excise & other levies, GST extra , execution of work at ceiling height up to 45 meter from plinth level of the building, all leads and lifts, all cost towards structural design & drawings, proof checking of structural design, all approvals, testing, etc. complete. Quoted rate shall also include the cost of providing and applying Zinc Phosphate primer before and after erection with minimum 75 microns and top coat with Low VOC Epoxy or Polyurethane paint with minimum 150 to 175 microns (DFT) of approved colour for all structural steel members. Mode of measurements: Actual weight of structural steel fixed at site including the weight of holding down bolts shall be measured for payment. Quoted rate shall include the cost of all materials, labour, cost of holding down bolts, fasteners, nits & bolts, all operations and process specified above, all wastages, steel scaffolding, infrastructure facility, tools and plants, all taxes, central excise & other levies, Octree/LBT, GST extra , execution of work at ceiling height up to 45 meter from plinth level of the building, all leads and lifts, all cost towards all testing, etc. complete. Quoted rate shall also include removing of existing plaster on RCC surfaces for fixing steel member , exposing steel member , civil works , removal of debries and disposal with campus , the cost of providing and applying Zinc Phosphate primer before and after erection with minimum 75 microns and top coat with Low VOC Epoxy or Polyurethane paint with minimum 150 to 175 microns (DFT) of approved colour for all structural steel members. All gaps shall be sealed with external grade silicon sealant with weather proof sealing material .ALL QUOTED RATES SHALL ALSO INCLUDE CONTRACTORS' ALL RISKS (CAR) INSURANCE POLICY ALONG WITH WORKMEN COMPENSATION COMPONENT EQUAL TO THE TENDERED AMOUNT. APPROVED MAKE OF STRUCTURAL STEEL : TATA / JSW / ESSAR | 5000.00 | kg |
5 | Supply, erection and fabrication of structural steel work in minimum grade FY310 in tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing and bending, curve shaping as per design in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete for Hot finished welded type tubes. Quoted rate shall be including providing and fixing the anchoring/holding down bolts of HILTI make as per structural design requirements on exiting RCC column/beams/ Brackets / Clamps including fastening straps, nuts, bolts, rivets, washers etc. as per proof checked design requirements and as per approved shop drawing. Brackets / Clamps shall be of hot dip galvanized steel and Fastening materials shall be Non - magnetic Stainless steel 300 series - 316 grade of Hilti make or approved equivalent. Galvanizing thickness shall be in accordance with IS 2629 and 4759. Providing and fixing Serrated plates or Serrated washer wherever required as per the system requirement and as shown in the approved shop drawing complete as per direction of Engineer in charge. Structural steel design as approved by IIT or COEP shall be referred for the erection purpose.Mode of measurements: Actual weight of structural steel fixed at site including the weight of holding down bolts shall be measured for payment. Quoted rate shall include the cost of all materials, labour, cost of holding down bolts, fasteners, nits & bolts, all operations and process specified above, all wastages, steel scaffolding, infrastructure facility, tools and plants, all taxes, central excise & other levies, GST extra , execution of work at ceiling height up to 45meter from plinth level of the building, all leads and lifts, all cost towards all testing, etc. complete. Quoted rate shall also include Contractors' All Risks (CAR) Insurance policy along with Workmen compensation component equal to the cost of tender shall be drawn , quoted rate alos includes removing of existing plaster on RCC surfaces for fixing steel member , exposing steel member , civil works , removal of debries and disposal with campus , the cost of providing and applying Zinc Phosphate primer before and after erection with minimum 75 microns and top coat with Low VOC Epoxy or Polyurethane paint with minimum 150 to 175 microns (DFT) of approved colour for all structural steel members. All open ends of main members, purlins, rafter or any other box sections shall be closed with MS sheet capping All gaps shall be sealed with external grade silicon sealant with weather proof sealing material.members.ALL QUOTED RATES SHALL ALSO INCLUDE CONTRACTORS' ALL RISKS (CAR) INSURANCE POLICY ALONG WITH WORKMEN COMPENSATION COMPONENT EQUAL TO THE TENDERED AMOUNT. APPROVED MAKE OF STRUCTURAL STEEL : TATA / JSW / ESSAR | 15000.00 | kg |