ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry Now
Construction Of Common Facilit, Jammu - Tender Details
Explore tender information for Construction Of Common Facilit in Jammu, including eligibility, deadlines, and bid specifics.
Jammu and Kashmir State Agro Ind. Dev. Corp. Ltd
Jammu, Jammu and Kashmir, India
NTID 39373570
Opening Date : Sat 8th March, 2025
Closing Date : Fri 7th March, 2025
- ₹ 0.00
- NTID 39373570
Construction Of Common Facility Center In Delhi -up-gradation Of Cold Rooms For Market Development Of Horticulture Package 4 Lawrence Road, Delhi.
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
1000000.00 -
Document Cost
11800.00 -
Estimated Cost
Refer Documents
BOQ Items Total Items : 37 | Total Qty : 14813
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply,installation & testing of PUF insulation with 100 mm PUF insulation material for existing chilled cold room -PUF Panel for Wall & Ceiling of 100 mm thickness, inclussive of all accessories as per specifications for chambers dimension - 21.5X15X12 mtr. -a) Insulation material -PUF Panels. b) Density -40 +/- 2 Kg/M3 c) Thickness of sheet - 0.5 mm TCT, PPGI d) Total Thickness-100 mm e) Thermal Conductivity - 0.023 W/mK f) Compressive Strength - 2.1 kg/ m2 (at 10% deformation) f) Make- Jindal,Rinac,Lioyd,BNAL, INDUSTRIAL FOAMS Note: Removal of Existing Insulation - Dismantling of existing EPS insulation from the existing cold rooms will be in the contractor s scope and carrying out minor repairs before installation of PUF panels in cold rooms. | 4950.00 | sq.m. |
2 | Supply, Installation, Testing and Commisssioning of Hinge Door for Existing Cold Room, 80mm thickness, Dimensions -1000 mm x 2000mm complete with all accessories as per specification :- Type of Door - Swing Door b) Dimensions - 1000 X 2000MM c) Type of panel - Sandwich panels constructed of a core of 80 mm PUF on both sides covered with 0.6 mm galvanized steel plate finished with 20mucoating. The panels are supplied with thermal bridge-free PVC surrounding profiles d) Sealing - All round with triple rubber profile e) Colour outside - RAL 9002 (white) f) Colour inside - Standard colour RAL 9002 (white/grey) g) Hardware - Galvanised Steel h) Finish of opening - To be Included i) Door Operation - Manual j) Locking Arrangement - To be Included k) Emergency Door Opening - to be provided Note: Removal of Existing Doors - Dismantling of existing swing doors of same dimension from the existing cold rooms will be in the contractor s scope and carrying out minor repairs before installation of new doors in cold rooms. (Make: Shakti Hormann, Metaflex, Infraca, Hicon) | 4 | Nos |
3 | Supply, Installation, Testing and Commisssioning of Hinge Door for Ante Chamber, 80mm thickness, Dimensions -1500 mm x 2100mm complete with all accessories as per specification :- Type of Door - Swing Door b) Dimensions - 1500 X 2100MM c) Type of panel - Sandwich panels constructed of a core of 80 mm PUF on both sides covered with 0.6 mm galvanized steel plate finished with 20mucoating. The panels are supplied with thermal bridge-free PVC surrounding profiles d) Sealing - All round with triple rubber profile e) Colour outside - RAL 9002 (white) f) Colour inside - Standard colour RAL 9002 (white/grey) g) Hardware - Galvanised Steel h) Finish of opening - To be Included i) Door Operation - Manual j) Locking Arrangement - To be Included k) Emergency Door Opening - to be provided (Make: Shakti Hormann, Metaflex, Infraca, Hicon) | 2 | Nos |
4 | Supply, Installation, Testing and Commissioning of Single stage reciprocating standby Compressor connect with existing compressor (1 nos. Standby) to be provided for catering to the refrigeration load of around 316 KW for Existing Cold Rooms. The system offered should be energy efficient with flexibility in operations to allow for multiple storage of products and partial loads in cold rooms incorporating latest technology. This compressor is proposed as replacement of existing compressor and allied equipment and should be integrated with the existing refrigeration system. This includes all miscellaneous spare parts and ancillaries required to complete the work. a) Compressor system to be provided of following specifications: 1. Compressor shall be 1 No (Standby) 2. Evaporating SST 5Deg C 3. Condensing SDT +40 Deg C 4. Refrigerant - Ammonia 5. Refrigeration System Pump feed, single stage reciprocating compressors 6. Type of Compressor - Single stage Reciprocating with belt driven drive through 7. Compressor Make: Bitzer /Kirloskar - KCX 6/ Frick /Mycom 8. 4 pole TEFC squirrel cage induction motor of 1440 RPM of suitable HP. (Make: ABB/CGL/Kirloskar/Siemens) 9. Complete Selection to be submitted for approval before execution of work at site. 10. Compressor should be provided complete with all accessories for integration with main plant including suction and discharge manifolds with isolating valves; safety relief valve; High/Low oil pressure gauge along with panel board; oil separator; High, low and differential pressure cuts out of Danfoss/ equivalent make; Oil gauge glass with valves, high pressure gauge and cut outs; other standard accessories including drive set, flywheel, belt guard, driven V-belts, base frame, toolkit, set of spare gasket, oil paper, wire filters, electrical fittings and etc. b. Refrigeration Piping, Fittings, Valves & Controls (as per requirement) The interconnecting ammonia piping between the various parts of the plant shall be scheduled seamless pipes upto 25mm NB and ERW C-class Heavy Duty Pipes thereafter (Makes Jindal/ Tata/ equivalent). The piping scope shall include supply of pipe lengths, necessary liquid feed assemblies comprising of solenoid valve, liquid strainer, stop valves, accessories like elbows. Tees, reducers, thermal break, clamps, threaded ends and fastener material etc. wherever required. Also included are primary and secondary steel structure and additional constructions for mounting the pipes and coolers and connecting the complete equipment. Valves for controlling the interlinked equipment like compressor, condenser, cooling water pumps, liquid ammonia receiver, chiller etc. and controls shall be viz. electronic float valve, ammonia solenoid valves, temp. humidity and pressure indicators, flow switches etc. (Make: Danfoss/ Manik/ equivalent). Digital temperature indicator cum controller of range -50 to +50 deg C (Make: AKO/Dixel/Equivalent) to control the auto run & defrost cycles with help of inbuilt timers & controls. Ammonia Gas leak detection system with alarms to be provided. c) Refrigeration line insulation & drain pipes (as per requirement) RPUF sections of suitable thickness with cladding of 26 gauge aluminium sheet is used for insulating the Ammonia pipes cold surface including intercooler, LPR etc. Drain Piping with GI B class pipe from units to outside the chiller shall be provided. Type of insulation for the drain pipe shall be Armoflex/ Vedoflex insulation along with heaters. d) Automation Panel (combined for complete plant) Programmable Logic Controller complete with display for automatic operation and control of refrigeration equipment as per standards. Basic control will consist of : 1) Automatic capacity control of compressors 2) Sequence control liquid pumps 3) Temperature Control and indication; RH control and indication 4) Warnings and failures indication 5) Possibility for automatic or manual operation Note: Integration of complete facility covering all cold rooms with automation panel already considered under supply in another tender. However, required sensors, controllers and connections for the existing cold rooms to be provided and integrated with the automation panel installed. e) Emergency lights to be provided in all cold rooms. f) Provision for handling accidental leakage of ammonia including Ammonia sensors in cold chambers near ACUs & plant room; gas leakage alarm system; Emergency ventilation for plant room; ammonia masks. (combined for complete plant). Note: Integration of complete facility covering all cold rooms with Gas Leakage detection & alarm system etc already considered under supply in another tender. However, required ammonia sensors near ACUs in existing cold rooms to be provided and integrated with installed system. g) Any other required work to complete the installation covering )Structure & Support Material including foundation for compressor, Painting for the equipment and all the pipelines after installation, First Charge of Ammonia Gas and Oil etc. | 1 | Lot |
5 | Supply, Installation, Testing, Commissioning of Evaporators of suitable capacity (reference capacity evaporator of 105 kw in each of 04 nos of existing chilled cold rooms. 1. EVAPORATOR OF REQUIRED CAPACITY OF 35 KW (03 NOS. PER COLD ROOM IN CHILLED COLD ROOMS WITH AROUND 3 AXIAL FANS OF AROUND 710MM, FIN SPACING AROUND 4 FPI. DESIRED AIR VOLUME AROUND 39000 M3/HR EACH, DEFROST - ELECTRIC, MAKES-ALFA LAVAL, THERMOFIN, GUNTNER, STAR COOLER) 2. CONTROLS, ACCESSORIES, etc as required 3.Make of Electrical Cable for all connecting cables - Polycab, Havells, Finolex, KEI 4.HANGING ARRANGEMENTS FOR EVAPORATORS FROM PEB BUILDING RAFTERS WILL BE IN CONTRACTOR SCOPE | 12 | Nos. |