ProcXpert
Share Your purchase requirement, Our ProcXpert team will Connect you to right Supplier.
Inquiry NowBalance Work Of Rera Office Co, Jammu - Tender Details
Explore tender information for Balance Work Of Rera Office Co in Jammu, including eligibility, deadlines, and bid specifics.
Municipal Administration Housing and Urban Development
Jammu, Jammu and Kashmir, India
NTID 39030991
- Opening Date : Wed 5th February, 2025
- Closing Date : Tue 4th February, 2025
- ₹ 18168000.00
- NTID 39030991
Balance Work Of Rera Office Complex At Gandhi Nagar, Jammu (part-2)
Documents
Get Complete Tender Details Now – Download the Document!
Buy This Document-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
-
721.3 kBOil_India_ExtraDoc...Oil_India_ExtraDocument-GCO0449P23.pdf
Costs
-
EMD
363360.00 -
Document Cost
2000.00 -
Estimated Cost
18168000.00
BOQ Items Total Items : 72 | Total Qty : 2297.08
# | Item | Quantity | Units |
---|---|---|---|
1 | Supply, Installation, Testing and Commissioning of 500 kVA copper wound oil cooled servo voltage stabilizer (including first oil fill) indoor type three phase unbalanced, with input voltage range 300 volt to 460 volt in phase to phase and output voltage range 400 volt 2% in phase to phase. with the following Protections: High and Low voltage cut off Protection. Short Circuit protection through MCCB Bye Pass arrangement etc Complete in all respects including end connections as approved by Engineer-in-Charge. | 1 | No |
2 | Supply, Installation, Charging, Testing and Commissioning of Air Cooled VRV/VRF units with rotary/scroll Compressor capable of modulating capacity from 20%- 100% working on R410A with heating & cooling both. The prices should include any lifting, shifting and positioning of outdoor units. The unit shall be factory charged & any top-up gas/oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The outdoor unit shall be a factory assembled unit housed in a sturdy weather proof casing constructed form rust-proofed mild steel panels coated with powder coated finish. The outdoor unit shall have multiple scroll compressors and be able to operate even in case of breakdown of one of compressor. Each floor shall be connected to one circuit and shall be commissioned floor wise with all machines on the terrace only. Each circuit of outdoor units shall have a minimum of 3 cans (ODU) for redundancy incase of breakdown. The heat exchanger for Outdoor shall be constructed with copper tubes mechanically bonded to aluminium fins to form a cross fin coil. The Condenser fins must be coated with Anti-corrosive treatment. The following safety devices shall be part of the outdoor unit:- High Pressure Switch, Low Pressure Switch, Fan Motor Safety Thermostat, Over Current Relay, Fusible Plugs, Fuses. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping. The outdoor units shall have a minimum COP of 3.8 at 100% loading condition in cooling only at outside ambient temperature of 42 deg.C dry bulb temperature and indoor temperature of 19 degree Celsius wet bulb temperature, the ODU shall have condenser fan capable of minimum 7 speeds for saving energy at various loading conditions. Minimum 60 Tr at 42 deg. Outside ambient conditions. (minimum 3 ODU in each circuit) | 1 | No |
3 | Supply, installation, testing and commissioning of below mentioned capacity ceiling mounted cassette type air conditioners complete with fan and fan motor, air cooled condenser propeller fan, controls, inter connecting refrigerant piping, insulation with corded remote control with each unit, cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. All indoor units to have NO/NC contacts for direct control from occupancy sensor if not then the manufacturer shall provide key card access for NO/NC contacts within the quoted rates. 4-WAY CASETTE INDOOR 4.0 TR | 4 | No |
4 | Supply, installation, testing and commissioning of below mentioned capacity ceiling mounted cassette type air conditioners complete with fan and fan motor, air cooled condenser propeller fan, controls, inter connecting refrigerant piping, insulation with corded remote control with each unit, cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. All indoor units to have NO/NC contacts for direct control from occupancy sensor if not then the manufacturer shall provide key card access for NO/NC contacts within the quoted rates. 4-WAY CASETTE INDOOR 2.0 TR | 10 | No |
5 | Supply, installation, testing and commissioning of below mentioned capacity ceiling mounted cassette type air conditioners complete with fan and fan motor, air cooled condenser propeller fan, controls, inter connecting refrigerant piping, insulation with corded remote control with each unit, cabling, earthing, necessary galvanized steel supports etc. as per specification and drawing. All indoor units to have NO/NC contacts for direct control from occupancy sensor if not then the manufacturer shall provide key card access for NO/NC contacts within the quoted rates. 4-WAY CASETTE INDOOR 1.6TR | 6 | No |